PubMed Health⌕ Search

Biomedical subjects

J M Gola

Publications and source records attributed to J M Gola.

4 recordsLinked to original sources

Ocular and nasal trigeminal detection of butyl acetate and toluene presented singly and in mixtures.

To probe into the rules of trigeminal chemosensory agonism in a binary mixture of chemicals we measured, first, the detectability (i.e., psychometric) function for eye irritation and for nasal pungency of butyl acetate and toluene, singly. (To avoid olfactory biases, nasal pungency was measured in a group of anosmics, i.e., persons lacking a functional sense of smell.) Then, based on the detectability function obtained for the individual chemicals, we prepared mixtures where the 2 components varied in their relative proportions but, if a simple rule of complete sensory agonism (in the sense of dose-additivity) were to hold, the mixtures should be as detectable as the reference concentration of each of the single chemicals. For both trigeminal endpoints (i.e., eye irritation and nasal pungency), the results showed that stimuli of relatively low detectability did show complete sensory agonism, whereas stimuli of relatively high detectability fell short of complete sensory agonism when compared with the detectability of the single substances. Further testing of additional binary and higher order mixtures will confirm whether or not a structure-activity model of trigeminal chemosensory impact of single chemicals, based on selected physicochemical parameters of the stimuli, can also be applied to chemical mixtures.

Acetates↗

Connection between chromatographic data and biological data.

There are no previous references to the direct use of GLC data in the correlation of biological processes, but we show that GLC retention data can be used in the correlation of several such processes involving gaseous solutes. There are a number of reports of RP-HPLC and MEKC data being used in the correlation of biological processes, but they are mostly restricted as to the number and type of solute studied. We show that if chromatographic data are used to obtain solvation descriptors for solutes, and if these descriptors are then used in the correlation of biological processes, that this indirect connection is a much more powerful and generally applicable method than is the direct connection between chromatographic data and biological data.

Chromatography, Gel↗

Comparison of two stimulus-delivery systems for measurement of nasal pungency thresholds.

Using representative members of each of three homologous series of chemicals-ketones, acetates and alcohols-we measured nasal pungency thresholds in anosmics via two stimulus-delivery systems. The first system consists of the fairly commonly used 270 ml, plastic 'squeeze bottles'. The second system consists of 1900 ml, glass vessels with Teflon tubing and nose-pieces. Although bulkier and more susceptible to mechanical breakage, the glass vessels possess advantages that can allow them to provide 'environmentally realistic' chemosensory thresholds, i.e. thresholds closer in absolute values to those that might be obtained under whole-body exposures. Such advantages include a larger volume of the vapor-source to accommodate whole sniffs, and a tight nose-nose-piece connection to avoid stimulus dilution. The outcome revealed that, for every chemical, the glass vessels provided nasal pungency thresholds significantly lower than those provided by the squeeze bottles. The difference amounted, on average, to a factor of 4.6, though the relative potency of the compounds remained the same under both systems. Additionally, when tested with the highest homologues used here, namely, octyl acetate and 1-octanol, anosmics using the glass vessels had little or no difficulty achieving the criterion for threshold whereas they did have difficulty when using the squeeze bottles.

Adult↗

Chemosensory detectability of 1-butanol and 2-heptanone singly and in binary mixtures.

Using 1-butanol and 2-heptanone as stimuli, we measured detectability (i.e., psychometric) functions for the odor, nasal pungency, and eye irritation of these two substances alone and in binary mixtures. Nasal pungency responses were tested in subjects lacking olfaction (i.e., anosmics) for whom odors do not interfere. Eye irritation responses were tested in normosmics and anosmics, and found to be similar in both groups so their results were pooled. When all stimuli--single and mixtures--were transformed into concentration units of one (or the other) chemical, a single function could fit all data from the same sensory end point with a correlation coefficient of 0.91 or higher. The outcome lends support, as a first approximation, to the notion of chemosensory agonism, in the sense of dose additivity, between the members of binary mixtures presented at perithreshold levels.

1-Butanol↗