PubMed Health⌕ Search

Biomedical subjects

J M González-Alba

Publications and source records attributed to J M González-Alba.

3 recordsLinked to original sources

Multicentric reference values for some quantities measured with the Elecsys 2010 analyser.

Several clinical laboratories in different regions of Spain have shared the search for reference individuals and the production of reference values for quantities concerning thyrotropin, non-protein bound thyroxine, triiodothyronine, cobalamines and folates, using an Elecsys 2010 analyser. All the logistic work has been done in co-operation with the supplier of the analyser (Roche Diagnostics España, S.L., Barcelona). The reference limits produced in the virtual laboratory are in fact derived from the blend of reference values obtained by each laboratory. The multicentric reference limits were estimated according to the recommendations of the International Federation of Clinical Chemistry. The work done represents a model of co-operation between the in vitro diagnostic industry and clinical laboratories for the production of reference values.

Reference Standards↗

Annual rhythmic and non-rhythmic biological variation of magnesium and ionized calcium concentrations.

The annual inter- and intra-individual biological variation, including the circannual rhythmic variation, of the serum concentrations of magnesium and ionized calcium has been investigated in a group of 51 apparently healthy volunteers. Venous blood specimens were collected on intervals of once a month within a one-year period, using a standardized protocol. The inter-individual coefficients of variation were 5.12% for magnesium and 1.58% for ionized calcium. The medians of the intra-individual coefficients of variation were 1.93% for magnesium and 2.18% for ionized calcium. These data were used to determine the allowable imprecision, the allowable systematic error, the critical difference for significant change detection, and the usefulness of population reference values (index of individuality). Of the quantities studied, only the serum concentration of ionized calcium shows a significant annual rhythmic variation (amplitude 1.3%), although this result may be due to the between-run metrological variance, considering that the concentration of ionized calcium of the control material used during the study possesses a similar significant rhythmic variation.

Adult↗

Multicentric reference values for some quantities measured with Tina-Quant reagents systems and RD/Hitachi analysers.

Ten clinical laboratories in different regions of Spain have shared the search for reference individuals and the production of reference values for quantities concerning ferritin, transferrin, rheumatoid factors, C-reactive protein and antistreptolysin O, using Tina-Quant reagents systems and RD/Hitachi analysers. All the logistic work has been done in co-operation with the supplier of the reagents and analysers (Roche Diagnostics España, S.L., Barcelona). The reference limits produced in the virtual laboratory are derived from the blend of reference values obtained by each laboratory. The multicentric reference limits were estimated according to the recommendations of the International Federation of Clinical Chemistry. The work done is a model of co-operation between the in vitro diagnostic industry and clinical laboratories for the production of reference values.

Adult↗