PubMed Health⌕ Search

Biomedical subjects

J M Hodgson

Publications and source records attributed to J M Hodgson.

At least 55 records · Page 3Linked to original sources

Evidence that selective endothelial dysfunction may occur in the absence of angiographic or ultrasound atherosclerosis in patients with risk factors for atherosclerosis.

OBJECTIVES: The purpose of this study was to test the hypothesis that endothelial dysfunction occurs in humans before the development of structural coronary atherosclerosis when risk factors for this disease are present. BACKGROUND: Animal studies have demonstrated that known risk factors for coronary atherosclerosis (hyperlipidemia, hypertension, diabetes) result in impaired endothelium-dependent vascular reactivity before the development of structural atherosclerosis. Previous studies in patients have been unable to distinguish early structural atherosclerotic disease from dysfunctional endothelium. METHODS: Twenty-six patients with angiographically normal coronary arteries were studied at cardiac catheterization. The epicardial arteries were imaged using high resolution intravascular ultrasound to detect early structural changes and to determine changes in lumen size during pharmacologic provocation. A selective intracoronary Doppler velocity catheter was subsequently used to determine coronary blood flow velocity changes in response to the same pharmacologic provocation. Group I (9 patients) had no risk factors for atherosclerosis. Group II (17 patients) had one or more risk factors present. RESULTS: Although both Groups I and II had a normal microvascular vasodilator response to adenosine or papaverine infusion (estimated coronary flow increase 396 +/- 200% vs. 326 +/- 161% [mean +/- SD], respectively, p = 0.103), only Group I patients had an intact response to acetylcholine infusion (378 +/- 203% vs. 75 +/- 93% in Group II, p = 0.001). Group II patients had an abnormal epicardial artery cross-sectional area vasoconstriction response to acetylcholine infusion (-16.6 +/- 12.4% [13 patients] vs. 1.3 +/- 11.5% in Group I, p = 0.0007). An additional four Group II patients had severe spasm during acetylcholine infusion. Epicardial vasodilator response to nitroglycerin infusion, however, was preserved in Group II (14.6 +/- 4.3% vs. 9.6 +/- 3.5% in Group I, p = 0.212). All Group I patients had normal vessels by intravascular ultrasound. Of the 17 patients in Group II, 7 had minimal disease on ultrasound (intimal thickening or small eccentric plaque) in the study vessel. These patients did not respond differently from the 10 Group II patients without demonstrable disease on ultrasound. CONCLUSIONS: Patients with risk factors for coronary artery disease, normal coronary angiograms and no measurable disease by intracoronary ultrasound exhibit selective endothelial dysfunction at both the epicardial and microvascular levels. These findings may have implications for the treatment of "preclinical" coronary atherosclerosis.

Acetylcholine↗

Local intramural drug delivery using an infusion balloon following angioplasty in normal and atherosclerotic vessels.

Local intramural delivery of various pharmacologic agents following angioplasty has been proposed as a means of reducing restenosis. This study tested whether local intramural delivery of aqueous solutions using an infusion balloon could be accomplished safely in normal vessels and whether such infusion was safe following standard angioplasty in diseased vessels. Infusion of aqueous agents into normal canine arteries had no adverse effect. Infusion of several aqueous agents (< or = 4 cc at 4 atm) into diseased swine iliac arteries following balloon angioplasty did not worsen existing or create new dissections. Histologically, infusion treated vessels did not differ in either model from vessels treated with angioplasty alone. We conclude that local intramural drug infusion does not create new, or worsen existing, dissections produced during standard balloon angioplasty in diseased vessels.

Angioplasty, Balloon, Coronary↗

Optimal data acquisition for volumetric intracoronary ultrasound.

Three-dimensional analysis using intracoronary ultrasound (ICUS) pull-back data provides the unique ability to quantitate lumen and atherosclerotic plaque volumes. Optimal data acquisition parameters for volumetric acquisition were established using simulations on computer phantoms of stenotic arteries. Eleven computer phantoms were generated using cross-sectional area data from quantitative angiography of stenotic coronary arteries. Three methods of data acquisition were simulated: conventional manual pull-back; motorized pull-back; and manual pull-back with measured displacement. Effects of pull-back velocity and cardiac gating on cross-sectional area profiles and volumes were studied. Cardiac gating eliminated errors introduced by vessel deformation within a cardiac cycle. With cardiac gating, pull-backs with mean velocities up to 1.2 mm/sec allowed reconstruction of cross-sectional area profiles within 5% RMS error. With faster pull-backs, cardiac gating resulted in sparse spatial sampling and significant errors in cross-sectional area profiles. The accuracy of both motorized and measured required equal displacements of the catheter proximal and distal ends. This assumption was validated with in vitro experiments where X-ray fluoroscopy was used to measure the displacement of the imaging tip. Excellent correlation was found between the two displacements (r = 0.99). Finally, slow pull-backs were performed by 3 operators, and pull-back velocities were measured. It was found that mean pull-back velocities as low as 0.8 mm/sec were achievable. From our simulations, we predict that accurate volumetric analysis requires cardiac gated, calibrated, slow (< 1.2 mm/sec) pull-backs.

Calibration↗

Volumetric intracoronary ultrasound: methods and validation.

Intracoronary ultrasound (ICUS) not only allows visualization of the vessel lumen, it gives a unique view of the transmural components of the artery wall. Analysis of lumen and plaque volume is necessary for studying atherosclerotic disease progression or regression and the mechanisms of therapeutic coronary interventions. A real-time, ICUS pull-back data acquisition scheme was developed to acquire calibrated, cardiac-gated volumetric image data sets. A semiautomated border detection scheme was implemented using dynamic programming. In phantoms, estimated area profiles were very reproducible as measured by the root-mean-square from the mean (3.8-5.9%). In phantom volume estimates, improved reproducibility (standard deviation = 1.2-3.6%) was obtained as positive and negative errors in area profiles were averaged out. Phantom volumes were also accurate when compared to true water displacement volume. The mean error ranged from -2.59 to -8.94%. When compared to quantitative single and biplane angiographic analysis, ICUS volumetric estimates tended to be superior to single plane analysis (error -5.06 +/- 2.48% vs -9.96 +/- 8.01%), but similar to optimal biplane analysis (error -5.06 +/- 2.48% vs -6.34 +/- 3.08%). In vivo reproducibility was assessed by performing multiple cardiac-gated pull-backs through experimentally induced stenosis. Over the length of the stenosis, excellent reproducibility of area profiles (+/- 5.9%) and volumes (+/- 1.9%) was obtained for cardiac-gated acquisitions. We conclude that volumetric ICUS provides accurate and reproducible estimates of lumen volume. Thus this technique may be of use in clinical trials where changes lumen volumes and vessel area profiles are of interest.

Animals↗

Coronary atherosclerosis in relation to body fatness and its distribution.

In a cross-sectional study of 226 patients (160 men and 66 women) who underwent coronary angiography, the relationships between total body fatness and abdominal fat distribution, and angiographically assessed coronary artery disease (CAD) were examined. Two different scoring systems were used to quantify the degree of CAD: an 'extent score' and a 'myocardial score'. The extent score provides an estimate of the extent of coronary atherosclerosis and the myocardial score provides an assessment of the amount of myocardium threatened by coronary lesions. Total body fatness was estimated using the body mass index (BMI) and the waist-to-hip circumference ratio (WHR) was used to assess abdominal fat distribution. The weight and height were obtained by questionnaire at the time of angiography, and self-reported waist and hip circumference measurements were used to calculate WHR. The BMI and WHR were associated with several coronary heart disease (CHD) risk factors. However, BMI was not significantly associated with either of the CAD scores. The WHR was positively associated with both the extent score (rs = 0.18; P < 0.05) and the myocardial score (rs = 0.17; P < 0.05) for men and women together, and positively associated with the myocardial score for women aged 40 to 70 years (rs = 0.32; P < 0.05). The associations between WHR and the CAD scores were not significant after adjusting for several risk factors for CHD. These results indicate that other risk factors for CHD may be involved in the associations between WHR and CAD.

Adolescent↗

Measurement by intracoronary ultrasound of in vivo arterial distensibility within atherosclerotic lesions.

Arterial distensibility is diminished by atherosclerosis. This process has not been well studied in the coronary arteries. The purpose of this study was to assess changes in coronary arterial distensibility in 4 groups of patients. Group I (n = 20) consisted of patients with normal vessels, group II (n = 40) with diseased undilated vessels, group III (n = 15) after successful percutaneous transluminal coronary angioplasty (PTCA), and Group IV (n = 20) after successful directional coronary atherectomy (DCA). Intracoronary ultrasound imaging was used to assess distensibility, plaque morphology and atherosclerotic burden (expressed as the percentage of total vessel cross-sectional area occupied by plaque: percent plaque area). Distensibility was defined as percent change in lumen area in a cardiac cycle. Group I (normal vessels) had a distensibility = 14 +/- 5%, which was significantly greater than that seen in group II (distensibility = 4 +/- 2%, p < 0.001). In undilated vessels, distensibility was related to the degree of atherosclerotic burden (r = 0.75). This relation was curvilinear with a marked decrease in distensibility when percent plaque area exceeded 30%. Distensibility in group III (after PTCA) was higher than in group II (10 +/- 3 vs 4 +/- 2%, p < 0.001) despite a larger plaque burden (percent plaque area of 56 +/- 12 vs 46 +/- 11%, p < 0.005). The distensibility in group IV (after DCA) was also higher than in group II (8 +/- 4 vs 4 +/- 2%, p < 0.001) despite a similar residual percent plaque area (49 +/- 13 vs 46 +/- 11%, p = NS).(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗

Mechanisms of angiographically successful directional coronary atherectomy: evaluation by intracoronary ultrasound and comparison with transluminal coronary angioplasty.

To assess the mechanisms of luminal improvement, 40 patients undergoing directional coronary atherectomy and a matched control group of 25 patients undergoing angioplasty were evaluated with intracoronary ultrasound imaging before and after intervention. Despite similar sized vessels, a similar angiographic severity of diameter stenosis (75 +/- 12% for the angioplasty group vs 69 +/- 15% for the atherectomy group, p = NS), and a similar plaque burden (percent plaque area) before intervention (84 +/- 5% in the angioplasty group vs 85 +/- 13% in the atherectomy group, p = NS), the residual plaque area after intervention was significantly smaller in the atherectomy group (54 +/- 14%) compared with the angioplasty group (65 +/- 13%, p = 0.002). Despite excellent angiographic results, significant residual plaque was noted after either successful intervention. Based on the absolute changes in lumen area, plaque area, and vessel area, improvement in the lumen area in the atherectomy group occurred as a result of plaque "compression" (48%), plaque removal (37%), and vessel expansion (15%). In the angioplasty group, plaque "compression" accounted for 94% of the improvement in lumen area, whereas vessel expansion contributed 6%. Thus "compression" of plaque remains the major mechanism of luminal improvement during atherectomy.

Aged↗

Intracoronary ultrasound imaging: correlation of plaque morphology with angiography, clinical syndrome and procedural results in patients undergoing coronary angioplasty.

OBJECTIVES: This study was designed to establish the relation between ultrasound-derived atheroma morphology and the clinical, procedural and angiographic features of patients presenting for coronary angioplasty. BACKGROUND: Intracoronary ultrasound imaging provides accurate dimensional information regarding arterial lumen and wall structures. Atheroma composition may also be assessed by ultrasound; however, only limited studies have been performed in patients. METHODS: In 65 patients a diagnostic ultrasound imaging catheter or a combination imaging-angioplasty balloon catheter was used during coronary angioplasty to image both the lesion and the vessel segment just proximal to it (reference segment). Ultrasound images were analyzed for lumen, total vessel and plaque areas and were classified into five morphologic subtypes (soft, fibrous, calcific, mixed plaque and concentric subintimal thickening). These data were compared with angiographic morphologic features, procedural results and clinical angina pattern (stable vs. unstable). RESULTS: Morphologic analysis of the ultrasound images obtained from the lesion correlated well with the clinical angina syndrome. Compared with patients with stable angina, patients with unstable angina had more soft lesions (74% vs. 41%), fewer calcified and mixed plaques (fibrotic, soft or calcific components in one or more combinations [25% vs. 59%]) and fewer intralesional calcium deposits (16% vs. 45%) (all p < 0.01). There was no correlation between ultrasound and angiographic lesion morphologic characteristics for either the reference segment or the lesion. Ultrasound demonstrated greater sensitivity than angiography for identifying unstable lesions (74% vs. 40%). Dimensional analysis demonstrated a large plaque burden in the reference segments (45 +/- 15% of total vessel area). Postangioplasty plaque burden was also high (62 +/- 9%). There was a significant, but only fair correlation between lumen area determined by angiography and ultrasound for both the reference segment (r = 0.70, p < 0.001) and the postangioplasty lesion (r = 0.63, p < 0.05). CONCLUSIONS: Morphologic plaque classification by ultrasound is closely correlated to clinical angina but has little relation to established angiographic morphologic characteristics. Intracoronary ultrasound imaging during angioplasty identifies a large residual plaque burden in both the reference segment and the lesion. In the future, determination of plaque composition by intracoronary ultrasound may be important in selecting or modifying interventional therapeutic options.

Aged↗

Can linoleic acid contribute to coronary artery disease?

The adipose tissue concentration of linoleic acid was positively associated with the degree of coronary artery disease (CAD) in a cross-sectional study of 226 patients undergoing coronary angiography. Linoleic acid concentration in adipose tissue is known to reflect the intake of this fatty acid. These results are therefore indicative of a positive relationship between linoleic acid intake and CAD. The platelet linoleic acid concentration was also positively associated with CAD. After confounding factors were allowed for, the eicosapentaenoic acid concentration in platelets was inversely associated with CAD for men, and the docosapentaenoic acid concentration in platelets was inversely associated with CAD for women; results consistent with several other studies that suggest that fish, and omega-3 fatty acids derived from fish and fish oils, can beneficially influence macrovascular disease.

Adipose Tissue↗

Improvement in arterial stiffness during hypolipidaemic therapy is offset by weight gain.

Fourteen patients with familial hypercholesterolaemia were managed with dietary advice and simvastatin for 12 months. Either nicotinic acid or cholestyramine resin was added to the regimen if serum cholesterol was not less than 5.5 mmol/l within 18 weeks. After dietary advice but before commencing pharmacotherapy for hyperlipidaemia, arterial stiffness was measured in the common carotid and common femoral arteries. These studies were repeated after 12 months on pharmacotherapy. The primary objective of this study was to determine whether arterial stiffness could be altered with total cholesterol and low density lipoprotein (LDL) cholesterol lowering. Over the 12 month interval, serum total cholesterol, LDL cholesterol and triglycerides fell significantly, whereas high density lipoprotein (HDL) cholesterol and body mass index (BMI) rose significantly. Mean supine blood pressure did not change significantly. Arterial stiffness in the common carotid artery decreased from 1.04 +/- 0.21 x 10(5) N/m2 to 0.63 +/- 0.06 x 10(5) N/m2 (T = -2.67, P < 0.01) over the interval. Stiffness of the common femoral artery decreased from 2.10 +/- 0.57 x 10(5) N/m2 to 0.83 +/- 0.15 x 10(5) N/m2 (T = -2.73, P < 0.01). The change in arterial stiffness was not directly related to changes in circulating lipids or supine blood pressure. Increase in BMI, however, correlated with change in arterial stiffness in the common femoral artery (Rs = 0.53, P < 0.05) but not in the common carotid artery. An increase in BMI was associated with a smaller decrease in common femoral arterial stiffness. Aggressive hypolipidaemic therapy was therefore associated with a favourable effect on arterial wall stiffness.(ABSTRACT TRUNCATED AT 250 WORDS)

Adolescent↗

Anomalous septal perforator artery: a source for supportive circulation in severe coronary artery disease--case reports.

Anomalous origin of a septal perforator artery is an infrequent angiographic finding. However, its recognition is important in patients with coronary artery disease in order to avoid misdiagnosis and consequent management mistake. In 2 patients, coronary arteriography demonstrated an anomalous septal perforator artery supplying significant blood flow to a myocardial region previously perfused by a severely obstructed major coronary vessel. It appears that an anomalous septal artery can serve as an important source for supportive circulation in severe coronary artery disease.

Aged↗

Imaging in the catheterization laboratory.

In the past decade, there has been dramatic growth in the number of catheterization procedures, with over 1.3 million performed in 1990. In the past year, several large studies have documented the clinical safety of nonionic contrast agents for performing angiography. These agents are much more expensive than conventional high-osmolarity ionic agents, and thus their widespread use continues to be controversial. Digital recording of angiographic images is now routinely available. Although useful for rapid review of images, digital processing for analysis of stenoses, ventriculography, and coronary flow has not been widely accepted. Several recent studies compared quantitative techniques with subjective analysis and found little advantage. Similarly, although flow can be determined, no practical clinical method has emerged. Over the past year, intracoronary ultrasound and angioscopy have made important advances. These adjunctive imaging techniques allow careful investigation of atheroma morphology and lumen geometry not available with routine angiography. Use of these imaging modalities will contribute greatly to the study of vascular disease in the catheterization laboratory.

Cardiac Catheterization↗

Percutaneous intravascular ultrasound imaging: validation of a real-time synthetic aperture array catheter.

This study was designed to validate the dimensional accuracy and ability to characterize atherosclerotic vessel morphology of a new percutaneously passed ultrasound catheter. The 5.5F catheter used for this study has a synthetic aperture array transducer providing a radial field of view perpendicular to the catheter and can be passed over a standard 0.014-in guide wire. Initial in vitro studies were performed to assess accuracy of dimensional and morphologic information. In vitro images of fixed human vessels demonstrated good boundary definition, and dimensional measurements were closely correlated with histological samples (luminal area, r = .97; maximal lumen diameter, r = .95; maximal wall thickness, r = .83). Morphological subtypes were also closely correlated, with increasing severity of histological atherosclerosis characterized by predictable changes in the ultrasound images. Subsequently, the catheter was passed percutaneously in 28 patients to obtain images of coronary (n = 20) and pelvic (n = 12) vessels. Ultrasound images were compared with simultaneous digital angiograms. Correlation between ultrasonic and angiographic estimations of vessel diameters was good (r = .92). We conclude that intravascular ultrasound imaging will be useful for dimensional and morphological characterization of vascular disease, for the study of regression or progression of atherosclerosis, and, potentially, for guidance of therapeutic interventions such as atherectomy and angioplasty.

Adult↗

Estimation of coronary flow reserve by intracoronary Doppler flow probes and digital angiography.

This prospective study investigated two different methods used clinically to estimate coronary flow reserve during cardiac catheterization. First, the relationship between simultaneous digital angiography and intracoronary Doppler velocity measurements was determined in 61 patients. The correlation coefficient for 233 simultaneous pairs of papaverine-induced flow reserve was 0.70 (Doppler = 0.41 digital + 0.93, P less than 0.0001). Repeated basal flow determinations showed little variability (Doppler: 2 +/- 5% (mean +/- 95% confidence intervals); digital: 3 +/- 10%). Repeated hyperemic flow estimates by the Doppler technique were more reproducible (10 +/- 2%) than those by the digital method (26 +/- 6%). Second, estimates of coronary flow reserve by side-mounted and end-mounted Doppler catheters were compared in vitro and in patients. In vitro measurement of blood velocity was linear for both catheter designs and was highly correlated with volume flow determined by electromagnetic flow meter (r = 0.99 side-mounted; r = 0.96 end-mounted). In patients (n = 20), average coronary flow reserve for the side-mounted Doppler crystal was 2.64 +/- 0.15 and for the end-mounted Doppler crystal was 2.40 +/- 0.14 (P less than 0.02). When flow reserve was determined twice for each catheter, there was greater variability in repeated measurements using the side-mounted Doppler crystal (21 +/- 10%, n = 14) than using the end-mounted Doppler crystal (12 +/- 4%, n = 32).(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗