[Harmonization of practices: application to the measurement of enzymatic activities used in prevention, screening, diagnosis and therapeutic monitoring].

The large metrological variation (CV, about 25%) observed between laboratories, at the national French level, for the measurement of enzymatic activities results in a loss of efficiency in using laboratory results. Current data show that the standardisation of methods is insufficient to solve this problem and needs to be completed by an harmonisation of the practices including the use of a common reference (calibrator). The present work, carried out by the joint working group between laboratories of the Centres for Periodic Health Examination and the French Society of Clinical Biology (SFBC), deals mainly with the feasibility and evaluation of the improvement of the consistency of the results. Twenty laboratories participated in this study. Five independent surveys were conducted during an height month period. Two enzymes were selected because of their clinical importance and their interest in prevention, screening, diagnosis or epidemiology: ALT (alanine aminotransferase) and GGT (gamma-glutamyltransferase). In each survey three kinds of samples i.e. control sera, candidate calibrators and human serum pools, each of them at two levels of activity (one physiological and the other pathological) were measured in duplicate. The low intra-laboratory imprecision and the high degree of the standardisation of used methods, due to an important effort previously done in this field, permitted to consider a common calibration. The stability and mainly the commutability, i.e. the ability for the candidate calibrator to show a behaviour similar to that of human samples towards the used methods, allowed to reduce the inter-laboratory variation by a half to two third-fold, reaching a coefficient of variation < 5% similar to those observed for cholesterolemia or glycemia. This level of consistency should permit to use common reference limits and common decision limits, after validation of this approach in real practice. The consequences of the harmonisation of practices, extended to the all laboratories, exceed largely the scope of this study. The reduction of the uncertainty and a better approach of the accuracy for the measurement of enzymatic activities should led to a real benefit for the patients in terms of prevention, screening, diagnosis or therapeutic monitoring and consequently for the public health.

Alanine Transaminase↗

[Enzyme calibrators: principle and practical use].

Results of catalytic activities of enzymes are highly dependent on the measurement procedures and on local conditions. Thus, only poorly marked improvement of interlaboratory comparability of results have been observed in clinical enzymology. To solve this problem, SFBC and IFCC have proposed to use "validated enzyme calibrators". Standardised operating procedures adapted to 37 C have been developed by IFCC for the most commonly used enzymes in clinical chemistry, and will be soon published. Reference materials which have been certified with these SOPs can be used as calibrators for a set of measurement methods which exhibit the same analytical specificity. Calibrators must be commutable, a property that must be checked experimentally. It is possible to produce stable and commutable materials for the calibration of a set of methods. Interest of this approach has been demonstrated for several enzymes. Results of two studies presented here show that the comparison of results to the upper limit of reference ranges does not improve the interlaboratory comparability of results in contrast to the calibration of different methods by a common calibrator which allowed to reach an interlaboratory CV close to 4% for ALT and gammaGT.

Calibration↗

[Influence of pyridoxal phosphate in measuring aminotransferases activities in patients with viral hepatitis].

Effect of a pyridoxal phosphate (PP) supplementation of reagents used for ALT and AST measurement was studied in serum of 20 patients suffering from viral hepatitis. Measurements of enzyme activities were carried out at 37 degrees C, using an automate (AU 600, Olympus). Significant differences (p < 0.0001) were observed both for ALT and AST, meanwhile they were more marked for ALT than for AST. This difference was associated with a strong interindividual variability regarding PP activation effect on ALT. In conclusion, aminotransferase measurements should be carried out with a reagent supplemented with PP, when the enzyme activity is used to evaluate a cytolysis. The same recommendation applies when ALT results are integrated into various combinations developed for the evaluation of liver status.

Adult↗

[A progress in the standardization in clinical enzymology using calibrators adapted to several techniques].

Results in enzymology obtained in routine conditions, differ considerably according to the measurement procedures, and the use of conversion factors is not an advisable solution. Some studies show that between-laboratory agreement of results can be improved by using validated enzyme calibrators. The conditions, which are required to define a strategy for the development of such calibrators, are described in a first part. The example of lipase activity, which is measured in routine conditions with important between-method discrepancy, is studied in a second part. This example emphasised the need of an a priori control of the validity of the calibrators. Under these conditions, between-method agreement is in fact considerably improved. With the collaboration of manufacturers for the development of validated enzyme multicalibrators, it will be possible to improve the efficiency of the information transmitted by clinical chemists to clinicians. Thus, enzyme activities measurements could benefit from the same improvement as immunoassay of proteins with the use of CRM 470 by manufacturers to calibrate their standards.

Calibration↗