Magnetic resonance imaging permits in vivo monitoring of catheter-based vascular gene delivery.

BACKGROUND: Gene therapy is an exciting frontier in modern medicine. To date, most investigations about the imaging of gene therapy have primarily focused on noncardiovascular systems, and no in vivo imaging modalities are currently available for monitoring vascular gene therapy. The purpose of this study was to develop an in vivo imaging tool to monitor a catheter-based vascular gene delivery procedure. METHODS AND RESULTS: We produced gadolinium/blue dye and gadolinium/gene-vector media by mixing Magnevist with a trypan-blue or a lentiviral vector carrying a green fluorescent protein (GFP) gene. The gadolinium was used as an imaging marker for magnetic resonance (MR) imaging to visualize vessel wall enhancement, and the blue dye/GFP was used as a tissue stain marker for histology/immunohistochemistry to confirm the success of the transfer. Using Remedy gene delivery catheters, we transferred the gadolinium/blue dye (n=8) or gadolinium/GFP lentivirus (n=4) into the arteries of 12 pigs, that were monitored under high-resolution MR imaging. The results showed, in all 12 pigs, the gadolinium enhancement of the target vessel walls on MR imaging and the blue/GFP staining of the target vessel tissues with histology/immunohistochemistry. This study shows the potential of using MR imaging to dynamically visualize (1) where the gadolinium/genes are delivered; (2) how the target portion is marked; and (3) whether the gene transfer procedure causes complications. CONCLUSIONS: We present a technical development that uses high-resolution MR imaging as an in vivo imaging tool to monitor catheter-based vascular gene delivery.

Animals↗

Endourethral MRI.

Although high-resolution MRI with phased array pelvic, endorectal, and endovaginal coils has dramatically enhanced the ability to visualize abnormalities of the female urethra and periurethral tissues, controversy still remains about the anatomy of this region. This study introduces an endourethral approach for ultra-high-resolution MRI of the female urethra and the periurethral tissues. To this end, two different radiofrequency (RF) receiver coil designs for an endourethral insertion have been developed: a single-loop coil and a phased array/quadrature coil. Both designs feature a flexible coil circuit, small loss tuning and matching directly at the coil, active decoupling, and the integration of a lambda/4 coaxial choke to decrease unbalanced currents and limit potential RF heating effects. Effective reduction of the mutual inductance between the two coils of the phased array design was achieved by introducing a metallic "paddle" to steer the flux between the coils. The performance of the coils has been evaluated in female human cadaver studies and in an in vivo pig experiment. The novel endourethral approach enabled a dramatic increase of the signal-to-noise ratio (SNR) at the region of interest (ROI). High-resolution MR images of the female urethra have been acquired with a spatial resolution down to 78 x 78 microm. Histologic correlation was achieved for the MR images generated. The achieved high local SNR and resulting high spatial resolution will add valuable information to the discussion of female urethral anatomy. Magn Reson Med 45:138-146, 2001.

Animals↗

In vivo measurement of pulsewave velocity in small vessels using intravascular MR.

A one-dimensional intravascular MR (IVMR) technique for the measurement of pulsewave velocity in a single cardiac cycle is presented. The technique was used to measure pulsewave velocity in vivo in the intact rabbit model, where its sensitivity to different hemodynamic states was demonstrated using a pharmacological intervention with phenylephrine and nitroprusside. IVMR measurements of pulsewave velocity were found to increase with mean arterial pressure, as expected. Further, IVMR-based pulsewave velocity estimates were in agreement with those measured by pressure catheters and direct distensibility measurement. Because of their rapidity and highly localized nature, these measurements of vessel elasticity may complement the high-resolution vascular imaging information gained in an IVMR examination. This could allow assessment of atherosclerotic plaques and facilitate immediate treatment decisions. Magn Reson Med 45:53-60, 2001.

Animals↗

Atherosclerotic plaques: classification and characterization with T2-weighted high-spatial-resolution MR imaging-- an in vitro study.

PURPOSE: To evaluate if T2-weighted high-spatial-resolution magnetic resonance (MR) imaging (117 microm per pixel) can help accurate classification of atherosclerotic plaques. MATERIALS AND METHODS: Thirty human arteries and 11 carotid endarterectomy specimens from 31 patients underwent T2-weighted MR imaging (2-T magnet; repetition time, 2,000 msec; echo time, 50 msec) at room temperature. After imaging, Bouin fixative was used to fix 26 arteries, and the other 15 arteries were fixed by means of freezing. Specimens were stained with hematoxylin-eosin and safranin or Sudan lipid stain. MR images and histologic slices were classified independently by two radiologists and a pathologist, respectively, on the basis of the American Heart Association classification. RESULTS: Results with MR imaging were the following: type I-II plaques, sensitivity of 67% and specificity of 100%; type IV-Va plaques, sensitivity of 74% and specificity of 85%; type Vb plaques, sensitivity of 90% and specificity of 100%; type Vc plaques, sensitivity of 80% and specificity of 90%. No type III plaque was diagnosed in the study. The overall kappa value was 0.68. CONCLUSION: High-spatial-resolution MR imaging with T2 weighting alone can help accurate classification of fibrocalcic plaques (type Vb), but it is subject to limitations for the classification and analysis of other types of atherosclerotic plaques.

Adolescent↗

Toward MRI-guided coronary catheterization: visualization of guiding catheters, guidewires, and anatomy in real time.

The success of x-ray fluoroscopy-guided coronary catheterization depends in part on the ability to obtain simultaneous and real-time visualization of the guidewire, guiding catheter, and anatomy of the chest. The hypothesis explored in this paper is that magnetic resonance imaging (MRI) could provide this ability. This hypothesis was tested with loopless antennas used as the guidewire and a guiding catheter and two surface coils, each connected to four different receiver channels of a GE 1.5-T CV/I MRI scanner. Experiments were conducted on six healthy dogs. Intravascular antennas were inserted in the right carotid artery and maneuvered in the aorta while running a fast gradient-echo sequence (TR/TE 5/1.3 msec, flip angle 7 degrees). Real-time projection images of the chest anatomy, together with the guidewire and guiding catheter, were obtained. Positioning of the MRI guiding catheter either in the descending aorta, ascending aorta, or heart was achieved easily. This study represents a step toward MRI-guided coronary catheterization.

Animals↗

Real-time projection MR angiography: feasibility study.

Intraarterial injections of small doses of gadopentetate dimeglumine were combined with a fast spoiled-gradient-echo magnetic resonance (MR) sequence to obtain real-time projection angiographic images of the rabbit aorta and canine coronary arteries. Arterial filling and washout, as well as venous and perfusion phases, were clearly displayed, demonstrating that arterial fluoroscopy in which an MR technique is used is feasible.

Adult↗

Accuracy of three-dimensional gadolinium-enhanced MR angiography in the assessment of extracranial carotid artery disease.

OBJECTIVE: The purpose of this study was to assess three-dimensional (3D) gadolinium-enhanced MR angiography, used alone or in association with duplex Doppler sonography, with a fast acquisition time (8 sec) for evaluating the extracranial carotid arteries. SUBJECTS AND METHODS: In this prospective study, 48 successive patients with carotid artery stenoses were examined with 3D gadolinium-enhanced MR angiography and 3D time-of-flight MR angiography. Of the 44 eligible patients, conventional angiography was available in 33 and duplex sonography in 27. We used the North American Symptomatic Carotid Endarterectomy Trial technique to quantify stenosis on all angiograms, and a 250 cm/sec threshold at duplex sonography to diagnose stenoses greater than 70%. Image quality of 3D gadolinium-enhanced MR angiography and 3D time-of-flight MR angiography was assessed, as well as sensitivity and specificity for each technique alone and in combination with duplex sonography. Conventional angiography was the gold standard. RESULTS: Three-dimensional gadolinium-enhanced MR angiography yielded good image quality in 90% of cases. When used alone, it yielded a sensitivity and a specificity of 94% and 85%, respectively, in screening stenoses greater than 70% (70-99%). When combined with duplex Doppler sonography, it provided a 100% sensitivity and specificity for detection of stenoses between 70% and 99% and would have obviated 61% of conventional angiography. In comparison, 3D time-of-flight MR angiography used alone yielded a sensitivity of 88% and a specificity of 94%. In combination with duplex Doppler sonography, its use would have obviated conventional angiography in 74% of cases. Three-dimensional gadolinium-enhanced MR angiography provided accurate results in the diagnosis of occlusions and ulcers and can visualize distant stenoses. CONCLUSION: Used alone, 3D gadolinium-enhanced MR angiography is not accurate enough to replace conventional angiography in the evaluation of extracranial carotid arteries. In association with duplex Doppler sonography, however, it is accurate and may obviate a significant number of conventional angiographic examinations.

Adult↗

Contrast-enhanced MR angiography: the effects of k-space truncation on luminal representation in a carotid artery phantom model.

Using carotid bifurcation phantom models with different degrees of stenoses, we evaluated the accuracy of vessel lumen representation on MR images obtained from the inverse Fourier transform of different k-space percentages. Our results show that the lower thresholds of truncated k-space sampling are dictated by the severity of luminal narrowing. The defined thresholds may help improve efficiency of 3D MR imaging of the carotid arteries while maintaining adequate luminal representation.

Carotid Arteries↗