Coronary calcium and atherosclerosis by ultrafast computed tomography in asymptomatic men and women: relation to age and risk factors.

We evaluated 675 men and 190 women who had no symptoms or history of clinical CHD, to determine the prevalence and risk factor correlates of CAC deposits as a marker of atherosclerosis. Measurements were taken noninvasively by ultrafast CT. The presence and extent of CAC deposits as measured by ultrafast CT was determined in all subjects, who also received personal and family medical history and risk factor questionnaire. The prevalence of CAC deposits increased significantly with age, ranging from 15% and 30% in men and women, respectively, < 40 years of age to 93% and 75% in those aged > or = 70 years. Prevalence and total score also increased by the number of risk factors present, although in those aged > 60 years a high prevalence (> 80% in men) of calcium was present regardless of the presence of risk factors. In multiple logistic regression, age, male gender, hypertension, diabetes, hypercholesterolemia, and obesity were independently associated with CAC deposits. These results suggest a high prevalence of atherosclerosis with increasing age and the presence of risk factors in men and women who have no symptoms. Studies to determine the prognostic value of CAC in individuals with no symptoms are needed to determine which populations may benefit most from CAC deposit screening.

Adult↗

Benefit of intracoronary ultrasound in the deployment of Palmaz-Schatz stents.

OBJECTIVES: This study was designed to evaluate the changes in intrastent and angiographic dimensions when intravascular ultrasound imaging is used to direct the deployment of balloon-expandable Palmaz-Schatz stents in coronary arteries and saphenous vein grafts. BACKGROUND: Intravascular ultrasound provides more information than angiography in the imaging of intravascular structures. Previous studies have shown that obtaining a larger lumen (greater "acute gain") with coronary interventions such as stenting leads to less restenosis and subacute thrombosis. It is not clear whether the information obtained by intravascular ultrasound can be used to obtain a greater acute gain in lumen dimensions. METHODS: Forty consecutive patients undergoing Palmaz-Schatz stent implantation had intravascular ultrasound imaging performed after a good angiographic appearance was obtained. If the stent did not appear adequately expanded by intravascular ultrasound, or if the struts were poorly apposed to the arterial wall, further stent dilation with larger balloons or higher pressure inflations were performed. Twenty-nine patients had subsequent intravascular ultrasound imaging. Intrastent diameters and areas were compared from the initial to the final intravascular ultrasound studies. RESULTS: Of the 40 patients studied, only 5 (13%) had an adequate result by intravascular ultrasound despite an acceptable angiographic appearance in all patients. Six additional patients did not undergo subsequent intravascular ultrasound imaging. The other 29 patients all demonstrated a significant increase in intrastent minimal diameter (mean 19%), major diameter (11%) and cross-sectional area (34%) (p < 0.001 for all measurements). CONCLUSIONS: The use of intravascular ultrasound imaging in the deployment of balloon-expandable Palmaz-Schatz stents leads to a significant increase in intrastent dimensions (greater "acute gain").

Aged↗

Determinants of patency after percutaneous angioplasty and atherectomy of occluded superficial femoral arteries.

BACKGROUND: Patients undergoing percutaneous recanalization of chronically occluded superficial femoral arteries were studied to determine which factors correlated with 1-year patency. Immediate change in ankle:brachial index (ABI), length of occlusion, tibial run-off, and the performance of supplemental catheter atherectomy were evaluated. METHODS: Eligible patients had at least one patient tibial run-off vessel and the absence of limb-threatening ischemia. Recanalization was performed via passage of a guidewire followed by balloon angioplasty. Tibial run-off was scored based on a modification of the angiogram scoring system of the Society for Vascular Surgery and the International Society for Cardiovascular Surgery. Supplemental transcutaneous extraction catheter atherectomy was randomly assigned to a sub-group of patients after initial experience with the recanalization technique. Clinical follow-up was employed to determine patency. RESULTS: Forty-two of 57 attempts (74%) at recanalization were immediately successful. Overall 1-year patency was 40% in 40 limbs that could be followed. In limbs with balloon angioplasty alone (n = 23), patency was 43% compared with 35% in those having supplemental atherectomy. Tibial run-off did not vary significantly between patent and occluded groups. When ABI increased by 0.3 or more, patency was 56% compared with 26% when the ABI increase was less than or equal to 0.1 (P = 0.13). Occlusion length averaged 18.1 +/- 10.6 cm for all limbs and did not vary significantly between early successes and failures. Limbs with short occlusions (less than or equal to 5 cm, n = 8) had 63% patency compared with 38% patency for limbs with long occlusions (greater than 25 cm, n = 16), but the difference was not significant by analysis of variance. CONCLUSIONS: An initial change in ABI was most predictive for patency, whereas no correlation with tibial run-off was demonstrated. Atherectomy did not increase patency. Short occlusions were more likely to remain patent than long ones, but overall patency was lower than described in other series.

Analysis of Variance↗

Preliminary experience with intravascular ultrasound guided Palmaz-Schatz coronary stenting: the acute and short-term results on a consecutive series of patients.

The purpose of this study was to prospectively test the hypothesis that systemic anticoagulation is not needed following coronary stenting when adequate stent expansion is achieved and documented and other flow limitations eliminated. Intravascular ultrasound (IVUS) was used to confirm adequate stent expansion, which was defined as good plaque compression together with the achievement of an intrastent lumen cross-sectional area (CSA) that was greater than 40% of the average reference vessel CSA. In this prospective study, Palmaz-Schatz coronary stenting was performed on 343 lesions in 263 consecutive patients. Primary stenting was successful in 254 patients (96.6%) and 332 lesions (96.8%). All patients with successful primary stenting underwent IVUS imaging except nine patients (13 lesions) that did not have an IVUS evaluation for technical reasons and three patients (4 lesions) in which IVUS was unsuccessful. The initial IVUS performed after achieving an acceptable angiographic result revealed inadequate stent expansion in 191 patients (79%) and 244 lesions (77%). After further dilatation, final adequate stent expansion was accomplished in 230 patients and 301 lesions. These patients were treated with Ticlopidine 250 mg twice per day for 2 months and did not receive postprocedure anticoagulation. There was one acute stent thrombosis (0.3%) that occurred in a lesion with slow flow and an inadequately expanded stent. There was no subacute stent thrombosis and no bleeding or vascular complications. We conclude that when adequate stent expansion is achieved and confirmed and other flow limiting lesions eliminated, that systemic anticoagulation after the stent procedure is not necessary.

Aged↗

Effect of balloon size and stepwise inflation technique on the acute results of Inoue mitral commissurotomy. Inoue Balloon Catheter Investigators.

Currently percutaneous transvenous mitral commissurotomy (PTMC) is performed by most operators using stepwise inflation of the Inoue balloon beginning at a small diameter and increasing size by a sequence of inflations to nominal diameter. The effect of balloon size on procedure results using the Inoue balloon has not been evaluated. In 260 patients final balloon inflation was to nominal size in 42% of pts, larger than nominal size (overinflated) in 10%, and less than nominal size (underinflated) in 48% of pts. The average number of inflations was 3 (range 1-9). Pressure gradient and Doppler mitral regurgitation (MR) were assessed after each inflation. When MR increased, further inflations were not done. Patients in whom the balloon was overinflated underwent more balloon inflations than those in whom it was inflated to nominal size (5.0 +/- 2.1 vs. 2.9 +/- 1.4, p < 0.01). Those with balloon underinflation had fewer balloon inflations (2.4 +/- 1.2 vs. 2.9 +/- 1.4, p < 0.01). The post PTMC valve area in patients with overinflation was slightly less than those with nominal inflations (1.6 +/- 0.4 vs. 1.8 +/- 0.7), and with underinflation the valve area was no different compared to nominal inflation. Using a stepwise procedure, if mitral regurgitation was noted to increase after a balloon inflation, the procedure would be stopped even if less than an ideal result was achieved. Fewer inflations were done in patients in whom the balloon was inflated to less than nominal size because of the appearance of mitral regurgitation.(ABSTRACT TRUNCATED AT 250 WORDS)

Calibration↗

Risk factor correlates of coronary calcium as evaluated by ultrafast computed tomography.

Coronary artery calcium is invariably associated with atherosclerosis and has been linked to an increased risk of coronary events. Ultrafast computed tomography (CT) was recently used to document the presence and relative quantity of coronary calcium. The use of the self-reported coronary risk factors to identify persons with coronary calcium as documented by ultrafast CT screening was examined in 458 men and 139 women aged 26 to 81 years (88% asymptomatic). All subjects underwent ultrafast CT scanning, and received a questionnaire and underwent an interview regarding medical and risk factor history. Total calcium score was calculated as the sum of lesion-specific scores, each calculated as the product of density > or = 130 Hounsfield units and area > or = 0.51 mm2. The prevalence of coronary calcium increased significantly (p < 0.01) by age group, and the greater the number of risk factors present, the greater the likelihood of calcium. From multiple logistic regression, age (p < 0.01), male sex (relative risk [RR] 3.03; p < 0.01), and history of smoking (RR 1.85; p < 0.01) and hypertension (RR 1.65; p < 0.05) were independently associated with the probability of detectable calcium. Among asymptomatic subjects, an association with hypercholesterolemia was also seen (RR 1.56; p < 0.05). The results demonstrate that cardiovascular risk factors can help in identifying the likelihood of coronary calcium.

Age Factors↗

Failure of angiography to accurately depict the extent of coronary artery narrowing in three fatal cases of percutaneous transluminal coronary angioplasty.

The angiographic and pathologic findings are described in three patients who died less than 24 h after failed percutaneous transluminal coronary angioplasty. In two of the three patients, coronary angiography performed before angioplasty disclosed apparently focal lesions in the left anterior descending and right coronary arteries. In these two patients quantitative angiographic analysis disclosed a minimal lumen cross-sectional area of 1.82 and 0.47 mm2, respectively, at the sites of apparently focal stenoses before angioplasty; corresponding percent lumen area narrowing measured 84% and 91%, respectively, by quantitative angiography at these two sites. In the third patient, coronary angioplasty was undertaken when the patient developed spontaneous occlusion of the right coronary artery several hours after diagnostic angiography. Retrospective quantitative angiographic analysis of the right coronary artery revealed a minimal lumen cross-sectional area of 1.14 mm2, with 85% lumen area narrowing at the site of subsequent total occlusion and angioplasty. In each of these three patients, necropsy examination disclosed that the distribution of coronary narrowing in the artery treated by angioplasty was in fact not focal; rather, in each of these three patients, the artery treated by angioplasty, as well as the extramural coronary arteries not treated by angioplasty, were severely narrowed by diffusely distributed atherosclerotic plaque. The angiographic and necropsy findings in these three patients document that coronary narrowing that remains occult by virtue of diffuse distribution may complicate evaluation of patients being considered for coronary angioplasty.

Adult↗

Morphological effects of coronary balloon angioplasty in vivo assessed by intravascular ultrasound imaging.

BACKGROUND: Histological examination of the effects of balloon angioplasty have been described from in vitro experiments and a limited number of pathologic specimens. Intravascular ultrasound imaging permits real time cross-sectional observation of the effect of balloon dilation on the atherosclerotic plaque in vivo. METHODS AND RESULTS: The morphological effects of coronary angioplasty were visualized at 66 lesions in 47 patients immediately after balloon dilatation with an intravascular ultrasound imaging catheter. Cross-sectional images were obtained at 30 frames per second as the catheter passed along the length of the artery. Quantitative and qualitative assessments of the dilated atherosclerotic plaque were made from the angiograms and the ultrasound images. Six morphological patterns after angioplasty were appreciated by ultrasound imaging. Type A consists of a linear, partial tear of the plaque from the lumen toward the media (seven lesions); Type B is defined by a split in the plaque that extends to the media (12 lesions); Type C demonstrates a dissection behind the plaque that subtends an arc of up to 180 degrees around the circumference (18 lesions); Type D was a more extensive dissection that encompasses an arc of more than 180 degrees (four lesions); and Type E may be present in either concentric (Type E1, 14 lesions) or eccentric (Type E2, 11 lesions) plaque and is defined as an ultrasound study without any evidence of a fracture or a dissection in the plaque. There was a large amount of residual atheroma in each type of morphology (7.8 +/- 2.9 mm2, 61.6 +/- 15.4% of cross-sectional area); there was no difference, however, in lumen or atheroma cross-sectional area among these six patterns. There was a good correlation between ultrasound and angiography for the recognition of a dissection. Calcification was seen in only 14% of lesions on angiography, whereas most lesions (83%) revealed calcification on ultrasound imaging. As determined by intravascular ultrasound, calcified plaque was more likely to fracture in response to balloon dilatation than noncalcified plaque (p less than 0.01). Thirteen of 66 lesions (20%) developed clinical and angiographic restenosis. Restenosis was more likely to occur when the original dilatation left a concentric plaque without a fracture or dissection (Type E1, 50% incidence) compared with a mean restenosis rate of 12% in the remaining morphological patterns (p = 0.053). CONCLUSIONS: Intravascular ultrasound provides a more complete quantitative and qualitative description of plaque geometry and composition than angiography after balloon angioplasty. In addition, intravascular ultrasound identified a subset of atherosclerotic plaque that has a higher incidence of restenosis. This information could be used prospectively to consider other therapeutic options in this subset. Intravascular ultrasound provides a method to describe the effects of angioplasty that will be useful in comparing future coronary intervention studies.

Adult↗

Anatomic and functional assessment of stenosis severity with intravascular ultrasound imaging in vitro.

An in vitro study was performed to evaluate the accuracy of intravascular ultrasound imaging compared with roentgenography for determining the cross-sectional area of a lumen; and to determine if the functional significance of an irregular stenosis is predicted more accurately by intravascular ultrasound than roentgenography. Varying degrees of stenosis were made in 17 rubber tubings by adjusting a plastic constrictor. The cross-sectional areas at the normal and the stenotic segments were determined by intravascular ultrasound, roentgenography, and then measured directly from an acrylamide gel cast of the lumen. To evaluate the functional significance of a stenosis, the pressure drop across the stenosis was measured using a fluid pumping circuit. The actual pressure drop was then compared with the predicted pressure drop derived from hydrodynamic equations using cross-sectional areas obtained by intravascular ultrasound or roentgenography. There was an excellent correlation between the cross-sectional areas at the tightest stenosis measured by intravascular ultrasound compared with the area from the acrylamide cast (7.2 +/- 2.6 v 6.6 +/- 2.4 mm 2, mean +/- SD, r = .93). Measurements of cross-sectional area from the roentgenograms (10.9 +/- 3.9 mm 2) also provided a relatively good correlation with those from the acrylamide casts (r = .84); however, the roentgenograms consistently overestimated the cross-sectional area of the stenosis. The mean values of the actual pressure drop and the predicted pressure drop by intravascular ultrasound and roentgenograms were 15.7 +/- 13.5, 11.3 +/- 11.9, and 4.3 +/- 4.5 mmHg, respectively.(ABSTRACT TRUNCATED AT 250 WORDS)

Angiography↗

Laser-assisted versus mechanical recanalization of femoral arterial occlusions.

A randomized clinical trial was performed to test the hypothesis that a laser-heated probe is superior to standard techniques to reopen occluded femoral arteries. Twenty patients were treated with a standard guidewire and balloon dilation method. In a second group of 20 patients, the laser probe was initially used as a nonheated mechanical device. If the probe was unsuccessful in mechanically reopening the artery, an Argon laser was activated to heat the probe. The mean length of occlusion was 15.9 +/- 10.3 cm. The success rate for the laser probe was 15 of 20 (75%), which was not significantly different from the standard method, 19 of 20 (95%). Most of the success in the laser-probe group was due to the probe's mechanical properties. The laser probe was successful as a cold, mechanical device in 13 of 15 (87%) arteries. It was necessary to heat the probe in 5 patients. When heated, the laser probe assisted recanalization in 2 but perforated the artery in 3 cases. The results of this randomized trial do not support the hypotheses behind the use of the thermal laser probe. The laser probe functions primarily as a mechanical device. The thermal activation does not significantly improve the success rate without increasing the risk of perforation. This small additional benefit does not justify the large cost of current thermal laser devices. This controlled study also demonstrates a higher success rate in long occlusions than previous reports of mechanical balloon recanalization. This is due to a combination approach of retrograde and anterograde probing of the occluded segment.

Adult↗

Intravascular ultrasound imaging following balloon angioplasty.

Despite its long history and reliability, contrast angiography has several inherent limitations. Because it is a two-dimensional projection image of the lumen contour, the wall thickness cannot be measured and the plaque itself is not visualized. This results in an underestimation of the amount of atherosclerotic disease by angiography. An assessment of atherosclerosis could be improved by an imaging modality: (1) that has an inherent larger magnification than angiography and (2) that directly visualizes the plaque. Intravascular ultrasound fulfils these criteria. This presentation will provide evidence that intravascular ultrasound may prove complimentary or even superior to angiography as an imaging modality. Intravascular ultrasound demonstrates excellent representations of lumen and plaque morphology of in vitro specimens compared with histology. There is very close intraobserver and interobserver variability of measurements made from intravascular ultrasound images. Phantom studies of stenoses in a tube model demonstrate that angiography can misrepresent the severity of stenosis when the lumen contour is irregular and not a typical ellipse, whereas intravascular ultrasound reproduces the cross-sectional morphology more accurately since it images the artery from within. In vitro studies of the atherosclerotic plaque tissue characteristics compare closely with the echo representation of fibrosis, calcification, and lipid material. In addition, in vitro studies of balloon angioplasty demonstrate that intravascular ultrasound accurately represents the changes in the structure of artery segments following balloon dilatation.

Angioplasty, Balloon↗

Intravascular ultrasound imaging of human coronary arteries in vivo. Analysis of tissue characterizations with comparison to in vitro histological specimens.

BACKGROUND: Intravascular ultrasound imaging was performed in 27 patients after coronary balloon angioplasty to quantify the lumen and atheroma cross-sectional areas. METHODS AND RESULTS: A 20-MHz ultrasound catheter was inserted through a 1.6-mm plastic introducer sheath across the dilated area to obtain real-time images at 30 times/sec. The ultrasound images distinguished the lumen from atheroma, calcification, and the muscular media. The presence of dissection between the media and the atheroma was well visualized. These observations of tissue characterization were compared with an in vitro study of 20 human atherosclerotic artery segments that correlated the ultrasound images to histological preparations. The results indicate that high-quality intravascular ultrasound images under controlled in vitro conditions can provide accurate microanatomic information about the histological characteristics of atherosclerotic plaques. Similar quality cross-sectional ultrasound images were also obtained in human coronary arteries in vivo. Quantitative analysis of the ultrasound images from the clinical studies revealed that the mean cross-sectional lumen area after balloon angioplasty was 5.0 +/- 2.0 mm2. The mean residual atheroma area at the level of the prior dilatation was 8.7 +/- 3.4 mm2, which corresponded to 63% of the available arterial cross-sectional area. At the segments of the coronary artery that appeared angiographically normal, the ultrasound images demonstrated the presence of atheroma involving 4.7 +/- 3.2 mm2, which was a mean of 35 +/- 23% of the available area bounded by the media. CONCLUSIONS: Intravascular ultrasound appears to be more sensitive than angiography for demonstrating the presence and extent of atherosclerosis and arterial calcification. Intracoronary imaging after balloon angioplasty reveals that a significant amount of atheroma is still present, which may partly explain why the incidence of restenosis is high after percutaneous transluminal coronary angioplasty.

Angiography↗

A comparison of excimer laser, thermal probe, and mechanical devices for recanalizing occluded human arteries.

To evaluate the mechanism of excimer laser recanalization and compare the results with those of laser-assisted thermal probe recanalization and mechanical recanalization, a total of 42 human atherosclerotic totally occluded arterial segments (2-15 cm long) were recanalized by excimer laser with a 400-800 micron quartz fiber pulsed at 20 Hz with 50 mJ/mm2 of energy (n = 21), an Argon heated thermal probe at 10-12 watts (n = 11), a guidewire directed through a 6 Fr multipurpose catheter, or an angioplasty balloon catheter (n = 10). On histologic examination, the excimer laster created a single round lumen or multiple lumens ("Swiss-cheese" like appearance) with no evidence of thermal injury at the perimeter of the lumen. The incidence of perforation in vitro was less with an excimer laser catherter (8/21 or 38%) than with the thermal prove (10/11 or 91%) (p less than 0.01). However, serial histologic cross-sectional examination showed that the pathway of the devices were essentially the same in all recanalization procedures. The pathway of the device was located outside the atheroma but proximal to the internal elastic membrane in 13 arteries with the excimer laser (62%), in 10 arteries with the thermal probe (91%), and 8 arteries with mechanical devices (80%). These results indicate that although the eximer laser could recanalize human atherosclerotic arteries without thermal injury, the fiber frequently deflected around firm atherosclerotic plaque and advanced in a dissection plane between the plaque and media. A similar course was noted for the thermal probe or during mechanical recanalization with a guidewire and catheter. To insure the safety of an excimer fiber or a thermal probe to reopen complete occlusions, better guidance systems must be developed.

Arteries↗