Fast low-angle dual spin-echo (FLADE): a new robust pulse sequence for structural imaging of trabecular bone.

Mechanical strength and fracture resistance of trabecular bone (TB) are largely determined by the structural arrangement of individual trabeculae. Fast 3D spin-echo approaches are preferable to gradient echoes in that they are less sensitive to local induced gradients at the bone/marrow interface caused by magnetic susceptibility difference between the two tissues. FLASE is a 3D pulse sequence that serves this purpose. Here, we present a new pulse sequence dubbed FLADE (fast low-angle dual spin-echo) that overcomes some of the limitations inherent to FLASE, such as sensitivity to artifactual stimulated echoes. The double-echo sequence features a flip angle <90 degrees allowing for TR << T(1). The second phase-reversal pulse has the dual function of creating a second echo and restoring inverted longitudinal magnetization. The prolonged TR, made possible by sampling only half of k(z)-space, is used to collect navigator echoes in adjacent slabs for sensing subpixel translational displacements. FLADE is shown to provide SNR comparable to FLASE while having narrower point-spread function and being more robust to imperfections in the nonselective 180 degree pulses. Structural parameters derived from the in vivo images with the two pulse sequences are highly correlated, therefore suggesting that clinical data obtained with either pulse sequence can be merged.

Bone and Bones↗

General algorithm for automated off-center MRI.

A general formula was derived that automatically modifies any MRI pulse sequence to realize arbitrary field-of-view (FOV) shifts. Unlike conventional techniques for implementing off-center MRI, the new method is completely automatic and can therefore be incorporated into the scanner hardware or software, thereby simplifying the development of MRI pulse sequences. The algorithm was incorporated into a visual pulse sequence programming environment, and several pulse sequences were programmed and tested at various off-center locations using the new technique. Unless there is significant background field inhomogeneity or gradient nonlinearity, research sequences employing the automatic technique need only be programmed and tested at the gradient isocenter, whereas with conventional methods, artifacts can sometimes depend on the position of the FOV.

Algorithms↗

Measurement of phosphorus content in normal and osteomalacic rabbit bone by solid-state 3D radial imaging.

In osteomalacia decreased mineralization reduces the stiffness and static strength of bone. We hypothesized that hypomineralization in osteomalacic bone could be quantified by solid-state (31)P magnetic resonance imaging (SS-MRI). Hypomineralization was measured with a 3D radial imaging technique at 162 MHz (9.4T) in rabbit cortical bone of hypophosphatemic (HY) and normophosphatemic (NO) animals. The results were compared with those obtained by quantitative micro-CT (micro-CT) and (31)P solution NMR. 3D images of 277 microm isotropic voxel size were obtained in 1.7 hr with SNR approximately 9. Mineral content was lower in the HY relative to the NO group (SS-MRI: 9.48 +/- 0.4 vs. 11.15 +/- 0.31 phosphorus wet wt %, P < 0.0001; micro-CT: 1114.6 +/- 28.3 vs. 1175.7 +/- 23.5 mg mineral/cm(3); P = 0.003). T(1) was shorter in the HY group (47.2 +/- 3.5 vs. 54.1 +/- 2.7 s, P = 0.004), which suggests that relaxation occurs via a dipole-dipole (DD) mechanism involving exchangeable water protons, which are more prevalent in bone from osteomalacic animals.

Anatomy, Cross-Sectional↗