Biomechanics of femoral interlocking nails.

Today there is a variety of different interlocking intramedullary nail designs available for the femur. We compared different nail types in the bone implant complex (BIC) of four unreamed solid nails and a slotted reamed nail with simulated comminuted mid shaft fractures to see if there are major differences in stiffness for axial load, bending and torsion. The fractures were simulated by a 2 cm defect osteotomy in paired human cadaver femora. Each bone was tested intact in a universal testing machine, osteotomy and osteosynthesis were performed, and the BIC was tested. Relative stiffness was calculated. In torque testing the unslotted solid nail showed significantly more stiffness (0.6-1.8 Nm/degrees) compared to the slotted nail (0.2 Nm/degrees). Compared to intact bone (6.9 Nm/degrees), both groups of nails were significantly less stiff (relative stiffness 2-20%). In axial load and bending testing the large diameter unreamed nail showed significantly higher stiffness (32-68%). This study shows that stiffness of bone implant complex in interlocking femoral nails is more dependent on nail profile than on the pressfit of nails in the medullary canal.

Adult↗

Stereo augmented reality in the surgical microscope.

We present an augmented reality system that allows surgeons to view features from preoperative radiological images accurately overlaid in stereo in the optical path of a surgical microscope. The purpose of the system is to show the surgeon structures beneath the viewed surface in the correct 3-D position. The technical challenges are registration, tracking, calibration and visualisation. For patient registration, or alignment to preoperative images, we use bone-implanted markers and a dental splint is used for patient tracking. Both microscope and patient are tracked by an optical localiser. Calibration uses an accurately manufactured object with high contrast circular markers which are identified automatically. All ten camera parameters are modelled as a bivariate polynomial function of zoom and focus. The overall system has a theoretical overlay accuracy of better than 1 mm. Implementations of the system have been tested on seven patients. Recent measurements in the operating room conformed to our accuracy predictions. For visualisation the system has been implemented on a graphics workstation to enable high frame rates with a variety of rendering schemes. Several issues of 3-D depth perception remain unsolved, but early results suggest that perception of structures in the correct 3-D position beneath the viewed surface is possible.

Depth Perception↗

Deformation of femoral nails with intramedullary insertion.

Current methods of distal interlocking of intramedullary femoral nails are dependent on image intensification. However, radiation exposure to the patient, the operating room staff, and the surgeon remains a concern. Proximally mounted, radiation-free aiming systems for distal interlocking of femoral nails have reportedly failed because of nail deformation with insertion. To better understand this deformation, a three-dimensional magnetic motion tracking system was used to determine the position of the distal interlocking hole following nail insertion. The amount and direction of deformation of commercially available small-diameter implants (unslotted 9-mm nails inserted without reaming) and large-diameter implants (slotted 13-mm nails inserted with reaming) from a single manufacturer were analyzed. Measurements of deformation (three translations and three angles), based on the center of the distal transverse locking hole, were performed on 10 paired intact human cadaveric femora before and after insertion. The technique produced the following results for the small and large-diameter nails, respectively: lateral translations of 18.1+/-10.0 mm (mean+/-SD, range: 47.8 mm) and 21.5+/-7.9 mm (range: 26.4 mm), dorsal translations of -3.1+/-4.3 mm (range: 15.2 mm) and 0.4+/-9.8 mm (range: 30.1 mm), and rotation about the longitudinal axes of -0.1+/-0.2 degrees (range: 0.7 degrees) and 10.0+/-3.1 degrees (range: 7.8 degrees). This technique is useful for measuring insertion-related femoral nail deformation. The data for the nails tested suggest that a simple aiming arm, mounted on the proximal end of the femoral nail alone, will not sufficiently provide accurate distal aiming.

Bone Nails↗

CT-based analysis of the geometry of the distal femur.

When applying minimally invasive techniques (MIO, Minimally Invasive Osteosynthesis) to the fixation of the distal femur, the surgeon has access to a limited number of anatomical landmarks: namely the articular surface of the distal femur and a small portion of the distal lateral femoral cortex. A detailed knowledge of the local anatomy facilitates the technique and prevents complications. Using Kirschner wires placed at set positions in the distal femur, we analyzed the measurements obtained from the 3D reconstructed helical CT scans of 33 embalmed femora and we report on the anatomy of the distal femur as it relates to supracondylar fracture fixation.

Femur↗

The deformation of small diameter solid tibial nails with unreamed intramedullary insertion.

'Radiation-independent' aiming systems for the placement of interlocking screws in intramedullary tibial nails have failed because of insertional related nail deformation. Prior to the development of these distal aiming systems, the variable position of the nails' interlocking holes after insertion must be known. In this study, the amount and direction of implant deformation of solid stainless-steel tibial nails (diameters of 8 and 9 mm, n = 20) were analyzed. Measurement of implant deflection (three translations, three angles) in the center of distal transverse locking hole was performed with a three-dimensional-magnetic motion tracker system after nail insertion in paired human cadaver tibiae. The results showed combined mean lateral translation of the 8 and 9 mm nails (n = 20) of -4.5 +/- 3.5 mm (range: 14.3 mm) and dorsal translation -7.8 +/- 5.8 mm (range: 19.2 mm). The combined mean rotational deformation about the longitudinal axis of the nail was 0.3 +/- 0.7 degree (range: 2.4 degrees). The authors conclude that a simple aiming arm, mounted on the proximal nail end alone, is not sufficient to provide accurate distal aiming.

Bone Nails↗

[Biomechanics of femoral interlocking nails at the bone-implant transition].

Today there is a variety of different interlocking intramedullary nail designs available for the femur-each designed with a different approach to achieve stability for fracture fixation. We compared different nail types in the bone-implant complex (BIC) of four unreamed solid nails and a slotted, reamed nail to see if there are major differences in stiffness for axial load, bending and torsion. We simulated comminuted mid-shaft fractures by a 2 cm defect osteotomy in paired human cadaver femora. Each bone was tested intact in a Universal testing machine. The results were recorded, osteotomy and osteosynthesis were performed, and the BIC was tested. Relative stiffness was calculated for each individual bone. For P-values less than 0.01 ('least significance difference test') the difference between groups was considered to be significant. In torque testing the unslotted solid nails showed significantly more stiffness (0.6-1.8 Nm/degree) compared to the slotted nail (0.2 Nm/degree). Compared to intact bone (6.9 Nm/degree), both groups of nails were significantly less stiff (relative stiffness 2-20%). In axial load and bending testing, the large-diameter unreamed nail showed greater higher stiffness (32-68%). This study shows that stiffness of the BIC in interlocking femoral nails is more dependent on nail profile than on the press-fit of nails in the medullary canal. For torque stiffness the absence of a slot is of special importance. According to our study, all of the unslotted nails tested give adequate stability for fracture fixation.

Adult↗

[Analysis of implantation-induced nail deformation and roentgen morphometric studies as the principle for an aiming device for distal interlocking nailing without roentgen image intensification].

While working to develop a distal locking device, we analyzed distal nail position with reference to nail deformation and a radiographic-morphometric investigation. The amount and the direction of implant deformation in unslotted stainless steel unreamed tibial nails (Synthes) were analyzed. Measurement of implant deformation (3 translations, 3 angles) in the center of the distal transverse locking hole was performed with a 3D magnetic motion tracker system before and after nail insertion. Unreamed tibial nails (diameter 8 mm, n = 10; diameter 9 mm, n = 10) were inserted in paired human cadaver tibiae. The results showed lateral translations of -4.5 +/- 3.5 mm (mean and standard deviation, range 14.3 mm) and dorsal translations of -7.8 +/- 5.8 mm (mean and standard deviation, range 19.2 mm). Rotational deformations around the longitudinal axis of the nail were 0.3 +/- 0.7 degree (mean and standard deviation, range 2.4 degrees). The results showed, that a simple aiming arm, mounted on the proximal nail end, alone or even in combination with a large working channel (e.g. 10 mm in diameter), was not adequate to the aiming process. A radiographic-morphometric analysis was subsequently performed in 40 tibiae after experimental (n = 20) or clinical (n = 20) implantation of nails 8 mm and 9 mm in diameter. These measurements showed a relatively constant distance between the upper distal transverse hole and the anterior aspect of the tibia (average 12.3 mm and only a narrow range (7.6 mm). These data were the basis for the development of an aiming technique that exploits the relatively constant distance between the distal nail hole and the anterior aspect of the tibia. This aiming device is set at a distance of 12.3 mm from the anterior cortex, and the fine tuning is finally resolved by the use of a "working channel' 10 mm in diameter.

Biomechanical Phenomena↗

[Voice control of endoscopic instruments by the operator--development and perspectives].

Present surgical techniques require the intraoperative control of an increasing number of technical devices (i.e. endoscopic surgery, fluoroscopy, laser systems). We present a system that allows direct command of medical devices by voice control. Practical testing of a voice-controlled arthroscopic fluid pump in the OR demonstrated safe and efficient function and a significantly improved control of the pump by the surgeon.

Arthroscopes↗