PubMed Health⌕ Search

Biomedical subjects

J Martínez Calatayud

Publications and source records attributed to J Martínez Calatayud.

At least 19 recordsLinked to original sources

Photo-induced fluorescence of fluometuron in a continuous-flow multicommutation assembly.

This paper deals with the photo-induced fluorimetric determination of the herbicide Fluometuron with the aid of a continuous-flow assembly of the emergent and new methodology known as Multicommutation which was provided with an on-line photoreactor. Maximum fluorescence intensity was observed at basic pH solutions, 1x 10(-4) mol l(-1) NaOH, after 1.4 min of irradiation and being the maximum at lambda(exc) 247.0 nm and lambda(em) 325.0 nm. The influence of different experimental parameters either chemical (pH, surfactants presence, solvent polarity and temperature) or hydrodynamic (time of photo-degradation, size and number of different segments and flow-rate) was tested. The linear dynamic range was from 0.01 to 4.0 mg l(-1) of Fluometuron; the inter-day reproducibility (as R.S.D.) of the slope was 0.001% and 1.7% from the peaks intra-day reproducibility. A large series of potential interferents was studied and finally the method was applied to human urine, soil, formulation and water samples.

Automation↗

Photo-induced chemiluminometric determination of Karbutilate in a continuous-flow multicommutation assembly.

The present paper deals with the chemiluminescent determination of the herbicide Karbutilate on the basis of its previous photodegradation by using a low-pressure Hg lamp as UV source in a continuous-flow multicommutation assembly (a solenoid valves set). The pesticide solution was segmented by a solenoid valve and sequentially alternated with segments of the 0.001 mol l(-1) of NaOH solution, the suitable media for the formation of photo-fragments; then it passes through the photo-reactor and was lead to the flow-cell after being divided in small segments which were sequentially alternated with the oxidizing system; 2 x 10(-5) mol l(-1) of potassium permanganate in 0.2% pyrophosphoric acid. The studied calibration range, from 0.1 microg l(-1) to 65 mg l(-1), resulted in a linear behaviour over the range 20 microg l(-1)-20 mg l(-1) and fitting the linear equation: I=(1180+/-30)C+(15+/-5) with the correlation coefficient 0.9998. The limit of detection was 10 microg l(-1) and the sample throughput 17 h(-1). After testing the influence of a large series of potential interfering species, the method was applied to water and human urine samples.

Calibration↗

Photoinduced chemiluminescence of pharmaceuticals.

A screening test for the forward development of chemiluminescence systems able to determine pharmaceutical compounds is reported. The test is based on the on-line photodegradation of the drugs by using a photoreactor consisting of 697 cmx0.5 mm PTFE tubing helically coiled around an 8 W low-pressure mercury lamp. Photodegraded pharmaceuticals are detected by direct chemiluminescence of the resulting photofragments and their subsequent reaction with potassium permanganate in sulphuric acid medium as oxidant. The screening comprised 97 compounds with different molecular structures and relevant members of the most important families of pharmaceuticals are tested (amino acids, carboxylic acids, nitrocompounds, phenyl-alkyl and aromatic amines, sulphonic acid amides, polycarbocyclics, monocyclic N-containing heterocyclics, bicyclic N-containing heterocyclics, tricyclic N-containing heterocyclics, N-S containing heterocyclics...). Due to the relevant influence of the medium for the photodegradation a wide range of pH's and buffer solutions were studied. The proposed strategy (photoinduced chemiluminescence, Ph-CL) allows the development of systems for the determination of many pharmaceuticals which do not present "native" chemiluminescence (e.g. chloramphenicol, dextromethorpham, riboflavin, ephedrine, piperazinamide, chlotrimazole, theophylline...). Moreover, Ph-CL allows to increase the sensitivity of chemiluminescence procedures based on direct chemiluminescence detection (e.g. sulphonamides, thiazides, nicontinamide, nortryptiline, levamisole, phenylbarbituric acid...).

Alkaloids↗

FIA-fluorimetric determination of the pesticide 3-indolyl acetic acid.

The paper presents the determination of the pesticide 3-indolyl acetic acid based on its native fluorescence; the method has been optimised either in a flow injection analysis (FIA) assembly or in batch. Maximum fluorescence intensity was observed at basic pH solutions at lambda(exc) = 280 nm and lambda(em) = 364 nm. The influence of different empirical parameters as pH, surfactants presence, solvent polarity, solved oxygen amount, and temperature was studied; highest outputs only required the pH in aqueous solutions to be adjusted over the range 9.5-10.5. Different calibration ranges were obtained by working with three different sensitivity scales of the fluorimeter either in flow injection analysis or batch. With the high sensitivity scale and FIA, the linear dynamic range was from 0.005 to 0.6 mg L(-1) 3-indolyl acetic acid; with an relative standard deviation (RSD) of 4.9% inter-day reproducibility. A large series of potential interferents was studied and finally, the method was applied to several water samples.

Buffers↗

Fluorescence determination of the pesticide asulam by flow injection analysis.

This paper presents the analytical determination of the pesticide Asulam based on its native fluorescence. The method was optimized in either a flow injection analysis (FIA) assembly or in batch. The maximum fluorescence intensity was observed for basic pH solutions and at a lamda(ex) of 258 nm and a lamda(em) of 342 nm. The influence of different empirical parameters, such as the pH, the presence of surfactants, solvent polarity or solved oxygen amount, was studied. The calibration range was fitted with a linear equation from 0.01-3 mg l(-1) Asulam and 0.005-15 mg l(-1) Asulam for batch and continuous-flow, respectively. The RSD for both procedures was 1.0%. After testing the influence of a large series of potential interferents, the method was applied to water samples from different locations.

Carbamates↗

Chemiluminescent determination of the pesticide bromoxynil by on-line photodegradation in a flow-injection system.

A new, robust and simple method is proposed for the chemiluminescent determination of the pesticide Bromoxynil. The empirical procedure is performed with the aid of a flow-injection manifold provided with an on-line photo-reactor to obtain chemiluminescent photofragments. After a period of 12 s of irradiation with an 8 W low-pressure mercury lamp, a chemiluminescent oxidation was performed with the system potassium permanganate in a polyphosphoric acid medium. The photolysis required a basic medium (KOH 0.014 mol l(-1)) with ethanol (1%) as a sensitizer. The method allowed the determination of 134 samples (h-1) of Bromoxynil in a wide interval of concentrations, over the range 5 x 10(-3) - 1 mg l(-1); the detection limit was 5 x 10(-3) mg l(-1). The RSD (n=24) at 0.25 mg l(-1) of the pesticide level was 2.3%. The method was applied to a water sample and to a formulation.

Flow Injection Analysis↗

Application of sequential injection analysis to pharmaceutical analysis.

Sequential injection analysis is a well established tool for automation of pharmaceutical analysis. A short historical background of this technique is given as well as a brief discussion on the basic principles and potentials. The current applications of SIA in the pharmaceutical analysis are also described and discussed. The manifolds developed offer good analytical characteristics and are suitable for analysis of drug formulations, process analysis, drug-dissolution, drug-release testing and functional assays for screening potential drugs. The results obtained are in good agreement with those furnished by the application of the reference methods presented in the pharmacopoeias.

Biological Availability↗

In situ generation of Co(II) by use of a solid-phase reactor in an FIA assembly for the spectrophotometric determination of penicillamine.

A flow injection analysis (FIA) manifold for the determination of penicillamine in pharmaceutical preparations is proposed. The manifold includes a solid-phase reactor for the in situ production of the derivatizing reagent, Co(II) ion, which forms a coloured complex with penicillamine in an alkaline medium. The reactor is prepared by natural immobilization of cobalt carbonate on a polymer matrix, which endows it with a high mechanical and microbiological stability. The cobalt released by passage of a 5 x 10(-4) mol l(-1) sulphuric acid stream at a flow-rate of 2.3 ml min(-1) is merged with a volume of 314 microl of sample containing penicillamine in ammonium-ammonia buffer at pH 9.5 to measure the absorbance at 360 nm. Beer's law is obeyed over the penicillamine concentration range 5-60 mg l(-1). The limit of detection (LOD) of the method is 1 mg l(-1) and its throughput 70 samples h(-1).

Cobalt↗

FI-chemiluminometric study of thiazides by on-line photochemical reaction.

The present manuscript deals with a simple and sensitive flow-injection method for the chemiluminescent determination of thiazides. The method is based on the on-line photodegradation and chemiluminescent determination of the resulting photo-fragments. The on-line photodegradation is performed in basic medium by using a photoreactor consisting of a 550cm long x 0.8mm ID piece of PTFE tubing helically coiled around an 8W low-pressure mercury lamp. The determination of the photo-irradiated thiazides is performed by a chemiluminescent oxidative reaction with Ce(IV) in sulphuric acid medium. A heterogeneous group of thiazides (indapamide, metolazone, hydroflumethiazide, chlorthalidone and bendroflumethiazide) has been studied. Hydrochlorothiazide was selected as a test substance. The "on-line" photochemical reaction approach allows the sensitive chemiluminescent determination of thiazides which do not present native chemiluminescence in the absence of sensitizers such as Rhodamine 6G. Linear calibration graphs were typically over the range 0.5-12 microgml(-1) (indapamide, metolazone, hydroflumethiazide and chlorthalidone); and over the range 0.5-5 microgml(-1) (hydrochlorothiazide). Limits of detection ranged between 0.005 microgml(-1) (hydrochlorothiazide) and 0.06 microgml(-1) (bendroflumethiazide). The relative standard deviation for the test substance was 2.0% for 2 microgl(-1) of the drug (n = 11) and the throughput was 65 h(-1) in all cases. The assessment of the photodegradation step on the molecular structure of thiazides was established by recording UV and fluorimetric spectra. The viability of the on-line photoinduced fluorescent determination of hydroflumethiazide and bendroflumethiazide was confirmed. The method was also applied to the determination of hydrochlorothiazide in commercially available formulation.

Flow Injection Analysis↗

Automated simultaneous triple dissolution profiles of two drugs, sulphamethoxazole-trimethoprim and hydrochlorothiazide-captopril in solid oral dosage forms by a multicommutation flow-assembly and derivative spectrophotometry.

This article deals with the simultaneous determination of three dissolution profiles with the aid of the new and emerging continuous-flow methodology known as multicommutation. This methodology is based on a flow network of a set of solenoid valves controlled by the computer and acting as independent multicommutators to allow the easy and automated control of flowing solutions. The obtained three dissolution profiles from one dosage form are the whole formulation profile or "global profile" recommended by pharmacopoeias, and, at same time, are recorded two "individual" profiles from two drugs present in the formulation. This is the second attempt to obtain simultaneously three dissolution profiles with a single spectrophotometric detector and the first with the multicommutation methodology. The selected pharmaceutical formulations contained a couple of active principles with overlapped spectra, namely sulphamethoxazole and trimethoprim or hydrochlorothiazide and captopril. The obtained empirical plots profiles fitted with the Higuchi equation also known as the three-parameter equation.

Administration, Oral↗

Three simultaneous dissolution profiles on a solid pharmaceutical formulation by a FIA manifold provided with a single spectrophotometric detector.

This article deals with the simultaneous determination of three dissolution profiles in the same pharmaceutical formulation. The officially proposed procedure from the pharmacopoeias is adapted to the FIA methodology to obtain the officially recommended profile or "global profile", and two "individual" profiles, corresponding to dissolution rate of two different active principles present in the formulation; both drugs have overlapped UV-vis spectra. The simultaneous determination of several profiles is based on the derivative spectra and the zero crossing mathematical procedure for the "individual" profiles of an active principle; the "global" profile of the formulation is obtained from the order zero derivative. The empirical profiles were adjusted by regression analysis using the three-parameter (Higuchi equation) plot method which was selected as the most suitable. The analytical errors when the concentration of one drug is very small or very high are also checked.

Amoxicillin↗

Simultaneous dissolution profiles of two drugs, sulfadiazine-trimethoprim and amitriptyline-perphenazine, in solid oral dosage forms by a FIA manifold provided with a single spectrophotometric detector.

The simultaneous determination of two dissolution profiles wih the aid of a flow injection analysis assembly has been applied to: (a) sulfadiazine-trimethoprim in tablets and (b) amitriptyline-perphenazine in sugar coated pills. The selected combinations are drugs which have overlapping UV-vis spectra. The officially proposed procedure from the pharmacopoeias has been adapted for the FIA methodology and derivative spectrophotometry and zero crossing. Preliminary experiments on the suitability of the simultaneous determination of both drugs were performed. The empirical profiles were adjusted by regression analysis using different approaches. The 3-parameter plot method was finally selected as the most suitable for the sulfadiazine-trimethoprim and the 4-parameter equation plot for amitriptyline-perphenazine.

Administration, Oral↗

Simultaneous dissolution profiles of two drugs in pharmaceutical formulations by an FIA manifold.

This article deals with the simultaneous determination of dissolution profiles of two drugs with overlapped spectra, present in the same pharmaceutical formulation. The official procedure for the dissolution profile is adapted to the continuous-flow methodology; the dissolution vessel is connected to an FIA manifold, in which the sample aliquots from the dissolution vessel are treated in order to adjust to the suitable pH and dilution degree to be monitored. The resulting solution is injected into the carrier stream, an acetic acid-acetate buffer at pH 4.3 and forced to the flow-cell of the spectrophotometer. The simultaneous determination of both profiles is based on the first derivative spectra and the zero-crossing mathematical procedure. The empirical profile of the curve is adjusted by regression using different approaches; the three-parameter plot method is selected. The analytical errors, when the concentration of one drug is very low or very high, are also checked. A binary mixture in commercially available formulations of solid oral administration of sulphametoxazole and trimethoprim is presented.

Anti-Infective Agents↗

Oxidation of adrenaline and noradrenaline by solved molecular oxygen in a FIA assembly.

A simple and effective procedure is proposed for the study and simultaneous determination of adrenaline and noradrenaline. The fluorimetric determination of both substances is performed in a flow injection assembly and by oxidation of both drugs with the solved molecular oxygen. The influence of different parameters is empirically studied and the interpretation of the reaction mechanism is also added. The determination of adrenaline is monitored at 450 nm and the outputs at 520 nm correspond to the adrenaline and noradrenaline global amount; for both lectures lambda(exc) 329 nm. The influence of temperature is relevant and analytical determination occurred at 55 degrees C by immersing the sample loop in a water bath. The linear range for adrenaline is over 0.5-20 microg ml(-1), limit of detection for both compounds is 0.2 microg ml(-1): the influence of foreign compounds as potential interferents is also tested; and, finally the procedure is applied to determination of both chatecolamines in synthetic samples.

Epinephrine↗

Prediction of the chemiluminescent behavior of pharmaceuticals and pesticides.

The present paper deals with the first attempt to apply molecular connectivity calculations to predict a chemical property with analytical usefulness: the chemiluminescent behavior of substances when reacted with common oxidants in a liquid phase. Preliminary evidence when searching for new direct CL methods consisted of the examination of analyte reaction with a wide range of oxidants and media. This task, which results in time-consuming and trial-and-error expensive procedures, is necessary due to ensure empirical or theoretical rules for CL prediction are available. On the other hand, in quantitative structure-activity relationship studies, molecular connectivity is a topological method capable of describing the structure of a molecule by means of numbers named indices; subsequent regression in relation to the experimental values of the physical, chemical, or biological properties yields a series of functions called connectivity functions. Discriminant analysis was applied to 200 either chemiluminescent or nonchemiluminescent substances found either bibliographically or in an experimental screening. The method used for the selection of descriptors was a stepwise linear discriminant analysis from the Snedecor F-parameter. The classification criterion used was the minimum value of Mahalanobis. The quality of the discriminant function was calculated through the Wilks U-statistical parameter. Finally, the function was applied to a database including of more than 50,000 structurally heterogeneous compounds. The theoretical predictions were faced with the empirical evidence obtained through a continuous-flow manifold.

Algorithms↗

Determination of nitrite by inhibition of the chemiluminescence of acriflavine in a flow-injection assembly.

The indirect determination of nitrite was performed with a flow-injection assembly on the basis of the inhibition of the analytical output obtained in a luminometer by oxidation of acriflavine. The acriflavine solution merged with the nitrite and the resulting mixture was injected into a pure water stream. This solution merged with the oxidant solution (potassium permanganate in sulfuric acid medium) and the resulting chemiluminiscence was affected (inhibited) by the presence of nitrite after reaction with the aminoacridine. The method was applicable over the range 10-800 microg l(-1) of nitrite with a correlation coefficient of 0.9960. The relative standard deviation was 1.4% and the throughput was 76 samples h(-1). The influence of foreign substances was also tested. A solid-phase reactor, filled with Amberlite IRA-900, was inserted in the assembly for the on-line preconcentration of nitrite; the analytical output resulted in an increase of up to 11.5-fold. The method was applied to the determination of nitrites in residual waters, industrial formulations and soil samples.

Acriflavine↗

o-Dianisidine: a new reagent for selective spectrophotometric, flow injection determination of chlorine.

A flow injection analysis (FIA) procedure for the determination of free chlorine in industrial formulations and water samples is proposed. The manifold is provided with a gas-diffusion unit which permits the removal of interfering species and also the preconcentration of chlorine. The determination of chlorine is performed on the basis of the oxidation by o-dianisidine as a chromogenic reagent to a coloured product which can be monitored at 445 nm. The method (for a preconcentration step of 60 s) is linear over the range 0.04-1.00 mg l(-1) of chlorine, the limit of detection is 0.04 mg l(-1), the reproducibility of the procedure (as RSD of the slope) is 3.7% for a series of four independent calibrations, the precision (as RSD of a series of 30 continuous FIA peaks of 0.56 mg l(-1) of chlorine) is 1.4% and the sample throughput is 40 h(-1). A detailed comparative study of the analytical characteristics of a single mono-channel reverse FIA assembly and the same system but provided with a Fluoropore membrane filter of 0.5 microm pore size was performed to check the advantages of the new approach in terms of sensitivity, selectivity and limit of detection.

Chlorine↗

Solid-phase reactors as high stability reagent sources in flow analysis: selective flow injection spectrophotometric determination of cysteine in pharmaceutical formulations.

The flow injection spectrophotometric determination of cysteine was carried out by reaction with cobalt(II) ions entrapped in a polymeric material and filling a packed-bed reactor; the released cobalt(II) complexed with the amino acid was monitored at 360 nm. The method worked with a high repeatability, even with independent reactors, days and solutions. Selectivity of the procedure was tested with twenty different foreign compounds found in pharmaceutical formulations containing cysteine, parent amino acids included; no serious interferences were observed. The calibration graph for cysteine was linear over the range 1-90 micrograms ml-1 with a relative standard deviation of 0.8% at 60 micrograms ml-1 (n = 158). The calculated sample throughput was 90 h-1. The method was applied to determine the content of cysteine in pharmaceutical formulations.

Cobalt↗