Is a learning curve for arterial switch operation in small countries still acceptable? Model for cooperation in Europe.

OBJECTIVES: To assess the results of a cooperative arrangement between Slovakia and Slovenia for neonatal cardiac surgery. The aim of the study was to analyze the performance of this approach for complete transposition of the great arteries (D-TGA). METHODS: Due to the overall small number of new patients with D-TGA in Slovenia a decision was made to avoid a prolonged learning curve by centralizing the experience of two countries at one center. Since 1995 the center in Slovakia has become the only referral center for Slovenia. Between February 1993 and June 2002 in this center, 147 patients with D-TGA underwent arterial switch operation (ASO). The median age at operation was 11 days, with 110 patients from Slovakia and 37 patients from Slovenia. RESULTS: Overall hospital mortality was 4.8% (seven patients). The 1, 2, 3, 4 and 5 year survival rate was 95% with the mean follow-up of 4 years. Operation before 1997 (P=0.0001) was identified as a risk predictor for death by multivariate analysis. There are no deaths among the 90 patients operated on after 1996. All patients are without medication with normal left ventricular function. Stenosis (gradient >30 mmHg) was noted in the pulmonary artery reconstruction in seven patients (5%). More than mild aortic regurgitation was noted in five patients (4%). The incidence of redo or reintervention was 5% at 5 years of follow-up. CONCLUSIONS: In the current era a prolonged learning curve for ASO is not acceptable to most European countries and their patients. The risk of surgery can be minimized by concentrating surgical experience as part of the quality control of congenital heart programs. If the number of new patients is small due to the birth rate and size of the population, institutions should merge activity. Such centralization amplifies the experience to the benefit of the patient.

Analysis of Variance↗

Morphological variations of secundum-type atrial septal defects: feasibility for percutaneous closure using Amplatzer septal occluders.

The aim of the study was to assess the morphology of secundum-type atrial septal defects (ASD) with a view to percutaneous closure using Amplatzer septal occluders (ASO). One hundred and ninety patients who underwent closure of isolated secundum-type ASD between September 1995 and January 2000 were included. The morphology of the defects was studied using transthoracic and transesophageal echocardiography. Patients with defects of suitable morphology and size underwent percutaneous closure using ASO. The remaining patients underwent surgical closure. Centrally placed defects were observed in 46 patients (24.2%). Morphological variations of secundum-type ASD were detected in 144 patients (75.8%). One hundred and fifty-one patients (79.5%) underwent percutaneous closure using ASO. Thirty-nine patients (20.5%) underwent surgical closure. Centrally placed defects, defects with deficient superior anterior rim, multiple defects, and perforated aneurysms of the interatrial septum are morphological variations of secundum-type ASD suitable for percutaneous closure using ASO. Cathet Cardiovasc Intervent 2001;53:386-391.

Adolescent↗

The role of transesophageal echocardiography in transcatheter closure of secundum atrial septal defects by the Amplatzer septal occluder.

BACKGROUND: Our purpose was to determine the role of transesophageal echocardiography (TEE) in the closure of atrial septal defects by the Amplatzer septal occluder (ASO) (AGA Medical, Golden Valley, Minn). METHODS: A total of 240 patients with atrial septal defect (ASD) secundum were examined by transthoracic 2-dimensional echocardiography (TTE) and TEE to determine the ASD morphologic features, diameter, and rims. During transcatheter closure TEE was used for determination of the ASD diameter and guidance of the ASO implantation. RESULTS: Sixteen (6%) patients were found not suitable for transcatheter closure with TTE, 35 (14%) with TEE, and 2 during catheterization. Twenty-eight patients (18%) had partial or total deficiency of the posterior, inferoanterior, or inferoposterior rim, 54 (27%) had a centrally positioned ASD, 92 (46%) had insufficient superoanterior rim, and 9 had multiple ASDs, whereas 8 had a septal aneurysm associated with a single defect and 4 a multiperforated aneurysm. A total of 170 patients underwent implantation of ASO. The ASO was correctly positioned in 144 at the first attempt. In the remainder TEE revealed unstable position of the left atrial disk (12), opening of both atrial disks in the left atrium (5), deployment of the device through the smaller defect in patients with multiple ASDs (3), and, in 1 patient, the device was too small and had to be replaced by a larger one. CONCLUSIONS: Morphologic variations of the ASD are common. TEE is crucial for the determination of the ASD morphologic features, diameter, and rims, which are crucial for proper patient selection. TEE allows precise guiding and positioning of the ASO, which is essential for safe and effective transcatheter ASD closure.

Adolescent↗

Early experience with the Amplatzer ductal occluder for closure of the persistently patent ductus arteriosus.

Using an Amplatzer duct occluder, 106 patients (weight 21 +/- 18 kg) underwent an attempt at catheter closure of a persistently patent ductus arteriosus (PDA). Their age ranged from 22 days to 48 years. The PDA measured between 1.2 to 8.1 mm at its narrowest diameter. The device was successfully implanted in 105 patients. The immediate closure rate was 70% and gradually increased to 100% at 1-month follow-up. There was no clinical evidence of hemolysis and no incidence of device embolization or bacterial arteritis. Doppler evaluation showed no evidence of aortic arch or pulmonary artery obstruction. The device, which is currently undergoing multicenter clinical trial in the United States, is proving to be a safe and effective device for closure of the persistently PDA.

Adolescent↗

[Transcatheter closure of ostium secundum atrial septal defects--initial experience with treatment of adult patients].

The authors present their initial experience with the use of Amplatzer septal occluder for transcatheter closure of secundum atrial septal defect. For patients where the secundum atrial septal defect type is haemodynamically significant or when paradoxical embolization via the defect is suspected, the catheterization technique is an alternative for cardiosurgical correction of the defect. The morphology of the defect which is the basic criterium for indication of a transcatheter closure is evaluated on transoesophageal echocardiographic examination. The closure takes place under skiascopic and transoesophageal echocardiographic control. The procedure in all three patients (2 women--age 58 and 62 years, 1 man--24 years) treated at our department was without complications. Consistent with formerly published data it may be concluded from our initial experience that when all indication criteria are respected the closure of secundum atrial defect by means of Amplatzer septal occluder is a safe technique and a relatively easy operation with a high rate of primary success.

Adult↗

Percutaneous closure of patent ductus arteriosus: complementary use of detachable Cook patent ductus arteriosus coils and Amplatzer duct occluders.

UNLABELLED: Several different devices were evaluated for the percutaneous closure of patent ductus arteriosus (PDA), and important drawbacks were found in all of them. To overcome these drawbacks, both detachable Cook PDA coils and Amplatzer duct occluders (ADO) were used for the percutaneous closure of PDA. A total of 54 patients underwent transcatheter occlusion of PDA at a median age of 4.5 years (range 0.5-29 years) and at a median weight of 19.5 kg (range 6-69 kg). Three patients were adults. Detachable Cook PDA coils were used in 26 patients with a median PDA diameter of 1.7 mm (range 1.1-2.2 mm) and ADO were used in 28 patients with a median PDA diameter of 3.8 mm (range 1.9-7.5 mm). Devices were successfully implanted in all 54 patients. Complete closure was achieved in 53 of 54 patients (98% closure rate). Median fluoroscopy time was 12 min (range 4-47 min). CONCLUSION: According to our experience, the complementary use of detachable Cook patent ductus arteriosus coils and Amplatzer duct occluders for the percutaneous closure of PDA can be recommended.

Adolescent↗

Undetected cardiogenic shock in patients with congestive heart failure presenting to the emergency department.

The purpose of this study was to examine the use of lactic acid levels and continuous central venous oxygen saturation (central venous oximetry) to stratify and treat patients with acutely decompensated end-stage chronic congestive heart failure (CHF) presenting to the emergency department. This prospective, convenience, non-outcome study was performed at an urban tertiary care hospital. Patients with end-stage CHF with an ejection fraction <30% presenting in decompensated CHF were eligible for the study. Patients were assessed using the Killip classification and New York Heart Association criteria. After lactic acid levels were obtained, patients were managed according to a standardized protocol guided by central venous oximetry. The patients were divided into high lactic acid (n = 22), low lactic acid (n = 5), and control groups (stable patients presenting to a cardiology clinic, n = 17) for comparison. There was no statistical difference in vital signs, or Killip and New York Heart Association criteria among the 3 groups. Central venous oxygen saturation was significantly lower in the high lactic acid group (32 +/- 12%) than in the normal lactic acid (51 +/- 13%) and control groups (60 +/- 6%) (p < 0.001). After treatment there was a significant decrease in lactic acid (-3.65 +/- 3.65 mM/L) and an increase in central venous oxygen saturation (32 +/- 13%) in the high lactic acid group compared with the normal lactic acid group (p < 0.001). A significant subset of patients with decompensated end-stage CHF present to the emergency department in occult shock and are clinically indistinguishable from patients with mildly decompensated CHF and stable CHF. Once identified, these patients require aggressive alternative management and disposition. Further study is necessary to identify whether this intervention impacts morbidity, mortality, and health care resource consumption.

Aged↗

Catheter closure of moderate- to large-sized patent ductus arteriosus using the new Amplatzer duct occluder: immediate and short-term results.

OBJECTIVES: The aim of this study was to assess the immediate and short-term results of anterograde catheter closure of a moderate- to large-sized patent ductus arteriosus (PDA) using the new self-expandable, respositionable Amplatzer duct occluder (ADO) device. BACKGROUND: Transcatheter closure of a PDA using devices or coils is technically challenging and may be accompanied by a 38% incidence of residual shunts. METHODS: Twenty-four patients (6 male, 18 female) underwent attempted transcatheter closure of a PDA using the ADO at a median age of 3.8 years (range 0.4 to 48) and a median weight of 15.5 kg (range 6 to 70). The mean PDA diameter at its narrowest segment was 3.7+/-1.5 mm. A 6F long sheath was used for delivery of the ADO. Follow-up evaluation was performed with color flow mapping of the main pulmonary artery within 24 h and at 1 and 3 months after closure. RESULTS: Twenty three of the 24 patients had successful device placement. Angiography showed that 7 patients had complete immediate closure, 14 had a trace shunt (foaming through the device with no jet), and 2 had a small residual shunt (with a jet). Within 24 h, color Doppler revealed complete closure in all patients. The unsuccessful attempt was during an initial trial with a prototype that has been modified. The median fluoroscopy time was 13.5 min (range 6.3 to 47). All patients were discharged home the next day. There were no complications. Of the 23 patients, 21 completed the 1-month follow-up, all (95% confidence interval [CI] 86% to 100%) with complete closure, and 18 of 23 patients completed the 3-month follow-up, also all (95% CI 83% to 100%) with complete closure. CONCLUSIONS: Anterograde transcatheter closure using the new ADO is an effective therapy for patients with a PDA diameter up to 6 mm. Further clinical trials are underway.

Alloys↗

Percutaneous closure of patent ductus arteriosus using special screwing detachable coils.

Jackson screwing detachable coils, developed for arterial and venous embolization, have been successfully employed recently for the percutaneous occlusion of patent ductus arteriosus (PDA). Special screwing detachable coils were designed for closure of the PDA, and the experience gained by their use is described in this report. Occlusion was attempted in 29 patients with a minimal ductal diameter of 0.9-4.2 mm. Coils were successfully placed in all 29 patients. One coil, which embolized 10 min after detachment, was retrieved. In 26 patients (89%), complete closure was achieved. Only 35 coils were placed in 29 patients. Residual shunts in three patients are minimal, detectable only on color-flow mapping. Screwing detachable coils for closure of PDA are safe and effective for occlusion of PDA with a minimal diameter < 4.2 mm. Embolization of the coil is very rare. A high closure rate is achieved with a low number of placed coils.

Adolescent↗

Transcatheter closure of secundum atrial septal defects using the new self-centering amplatzer septal occluder: initial human experience.

Transcatheter closure of secundum atrial septal defect (ASD) using clamshell or buttoned devices is accompanied by a high incidence of residual shunt. Recently, a new self-centering device, the Amplatzer septal occluder (ASO), has been evaluated in an animal model with very good results. Therefore, our purpose is to report on our initial clinical experience with this device. Thirty patients underwent an attempt at catheter closure of their ASDs at a median age of 6.1 yr (range, 2.9-62.4 yr) and median weight of 22 kg (range, 13-69 kg) using the ASO. The median ASD diameter measured by transesophageal echocardiography (TEE) was 12.5 mm (range, 5-21 mm), and the median ASD balloon stretched diameter was 14 mm (range, 7-19 mm). All patients had right atrial and ventricular volume overload with a mean +/- SD Qp/Qs of 2.3 +/- 0.6. A 7F catheter was used for delivery of the device in all patients. The device was placed correctly in all patients. There was immediate and complete closure (C) in 17/30 patients, 10 patients had trivial residual shunt (TS), and 3 had moderate residual shunt (MS). The median fluoroscopy time was 15 min (range, 8-35 min), and the median total procedure time was 92.5 min (range, 40-135 min). There was no episode of device embolization or any other complication. Follow-up was performed using transthoracic echocardiography (TTE) 1 day, 1 mo, 3 mo, and yearly thereafter. At 1 day, there was C of the ASD in 24/30 patients, 3 had TS, 1 had small shunt (SS), and 2 had MS. At a median follow-up interval of 6 mo, there have been no episodes of endocarditis, thromboembolism, or wire fracture. We conclude that the use of the new ASO is safe and effective in complete closure of secundum ASDs up to a diameter of 21 mm in the majority of patients. Further clinical trials are underway.

Adolescent↗

Effects of warfarin on markers of hypercoagulability in patients with heart failure.

Heart failure is associated with a hypercoagulable state. A single-center, randomized, double-blind, placebo-controlled trial was performed to test the hypothesis that warfarin will modify a hypercoagulable state in heart failure. This study included 76 patients with heart failure. At baseline, patients had evidence for a hypercoagulable state with elevated plasma levels of thrombin/antithrombin III (TAT) complexes (3.4 +/- 2.0 ng/ml), prothrombin fragment F1 + 2 (1.5 +/- 0.9 nmol/L), and D-dimers (630 +/- 401 ng/ml). Warfarin therapy (international normalized ratio [INR] 2.7 +/- 1.3) significantly decreased plasma levels of TAT complexes (p < 0.002), F1 + 2 (p < 0.001), and D-dimers (p < 0.001) when compared with baseline values at 1, 2, and 3 months of therapy. In contrast, patients receiving placebo had persistent elevation of TAT complexes (p = not significant [NS]), F1 + 2 (p = NS), and D-dimers (p = NS) during follow-up at 1, 2, and 3 months. The two treatment groups followed different trends over time for all three markers (p < 0.001). The effect of low-intensity warfarin (INR 1.3 +/- 0.08) versus moderate-intensity warfarin (INR 2.3 +/- 1.1 ) on markers of hypercoagulability was evaluated in 14 patients. When compared with baseline, low-intensity warfarin administration decreased plasma levels of TAT complexes (p = NS), F1 + 2 (p = 0.05), and D-dimers (p = 0.04). In these patients F1 + 2 was further reduced with moderate-intensity warfarin (p < 0.001). Our findings suggest that a hypercoagulable state in heart failure can be modified by warfarin therapy.

Adult↗

Five-year follow-up after balloon pulmonary valvuloplasty.

OBJECTIVES: The aim of this study was to assess results 5 years after balloon pulmonary valvuloplasty. BACKGROUND: Since the technique of balloon pulmonary valvuloplasty was first reported in 1982, it has become the treatment of choice for pulmonary valve stenosis. In contrast to surgical valvotomy, the long-term outcome after balloon pulmonary valvuloplasty is unknown. METHODS: We reviewed the findings in 34 patients 5.2 +/- 0.8 (mean +/- SD) years after balloon pulmonary valvuloplasty: 27 with isolated pulmonary stenosis, 5 with Noonan syndrome and 2 with previous surgical valvotomy. In eight patients (three with Noonan syndrome), a second balloon valvuloplasty was the index procedure for analysis. RESULTS: The transpulmonary gradient (mm Hg) was 74 +/- 34 before balloon pulmonary valvuloplasty, 36 +/- 26 immediately after, 22 +/- 9 at cardiac catheterization in 29 patients 6 +/- 0.6 months later and 19 +/- 10 by Doppler study at 5 years. At 5 years 26 patients (group A) had a residual gradient of < or = 20 mm Hg; the remaining 8 (group B) had a gradient of > 20 mm Hg. Four group B patients had Noonan syndrome (p = 0.01). Balloon/pulmonary valve diameter ratio was larger for group A patients than for group B patients with isolated pulmonary stenosis (1.20 +/- 0.10 vs. 1.00 +/- 0.07, p = 0.005); larger balloons were used in group B patients with Noonan syndrome (1.30 +/- 0.10). Group A patients were more likely than group B patients to have significant pulmonary incompetence (6 of 24 vs. 0 of 8) and had a greater right ventricle/left ventricle long-axis diastolic dimension ratio (0.47 +/- 0.10 vs. 0.35 +/- 0.04, p = 0.05). In the subgroup of five patients with Noonan syndrome and two with prior surgical valvotomy, the transpulmonary gradient was reduced from 74 +/- 24 mm Hg before balloon valvuloplasty to 23 +/- 12 mm Hg at 5 years. In addition, two patients with isolated pulmonary valve stenosis had pulmonary valve dysplasia by angiographic criteria: transpulmonary gradients of 85 and 56 mm Hg were reduced to 20 and 11 mm Hg, respectively, at 5 years. CONCLUSIONS: Relief of obstruction persists at 5 years especially if oversized balloons are used. Acceptable results can be obtained in patients with a dysplastic valve. More complete relief of right ventricular outflow gradient is associated with increased right ventricular dimension, probably because more pulmonary incompetence is induced. This is well tolerated at 5 years but may be important in the longer term.

Blood Pressure↗

[Familial supravalvular aortic stenosis].

By means of two dimensional echocardiography supravalvular aortic stenosis was diagnosed in two siblings and their cousin. Autosomal dominant transmission with incomplete penetrance or even non-penetrance is assumed to be involved. Somatic stigmatization, typical for Williams' syndrome, failed to be present in the affected children. The reported family provides further evidence that familial supravalvular aortic stenosis and Williams' syndrome are two distinct clinical entities. (Tab. 1, Fig. 3, Ref. 23.)

Aortic Valve Stenosis↗

[How can the Williams-Beuren syndrome be recognized?].

In a girl with Williams-Beuren's syndrome psychological examination revealed mental retardation with a special mental profile, angiography revealed peripheral pulmonary stenoses, echocardiography a slight stenosis in the supravalvular aortal area and anthropometry typical facial signs. Indirect signs of hypercalcaemia were clinical signs of poor progress during infancy. The authors emphasize that accurate analysis of basic clinical signs and the natural development of the disease are the key to its diagnosis.

Aortic Valve Stenosis↗