PubMed Health⌕ Search

Biomedical subjects

J Mauri

Publications and source records attributed to J Mauri.

At least 37 records · Page 2Linked to original sources

[Stenosis of the common trunk with and without ostium involvement: clinical and angiographic characteristics].

STUDY OBJECTIVE: To evaluate the clinical and angiographic profile of patients with left main coronary artery stenosis with (LM-OS) and without left coronary ostial stenosis (LM-NOS). DESIGN: Retrospective study of patients submitted to coronary angiography. SETTING: Laboratory of Hemodynamics and Interventional Cardiology at Bellvitge Hospital -Barcelona, Spain. PARTICIPANTS: 4663 consecutive patients (pts) with angiographically defined coronary artery disease. 139 pts had left main stenosis greater than or equal to 50%. Twelve pts were excluded because nonatheroesclerotic disease. Twenty two pts (17%), had LM-OS and 105 (83%) LM-NOS. INTERVENTIONS: Pts records were reviewed, to analyse the following clinical and angiographic variables: age, gender, risk factors to coronary artery disease, history of myocardial infarction, anginal class, presence of unstable angina, basal ECG ischemia, percentage and localization of left main stenosis, number and degree of vessels diseased, indexes of left ventricular function and coronary dominance. MAIN RESULTS: 1. Clinical characteristics--In the LM-OS group 18 pts were male and 4 female, while in the LM-NOS the numbers were respectively 90 and 15, p = ns. As for the gender the age showed also a similarity: 58 +/- 8 and 57 +/- 8 years, p = ns. A history of arterial hypertension was present in 73% of pts with LM-OS and 47% with LM-NOS, p greater than 0.05. With respect to the other clinical variables both groups were similar. The incidence of LM-OS was 0.4%. 2. Angiographic characteristics--The severity of left main stenosis was identical in the two groups: 80 +/- 15 in LM-OS and 75 +/- 16% in LM-NOS (p = NS). Four (18%) of the pts with LM-OS had no associated coronary disease versus 7 (7%) of the LM-NOS (p = 0.08). There were 1.3 +/- 1 diseased vessels in the LM-OS group and 2.1 +/- 1 in the LM-NOS (p greater than 0.01). CONCLUSIONS: In the present series, the clinical and hemodynamic profile of patients with left main disease suggest that the following characteristics are more frequently seen in patients with ostial stenosis: 1) history of arterial hypertension; 2) no associated coronary disease; 3) smaller number of diseased vessels; 4) less significant stenosis.

Aged↗

[Residual myocardial function in dilated myocardiopathy. Response to post-extrasystolic potentiation].

OBJECTIVE: to evaluate the effectiveness of post-extrasystolic potentiation (PESP) to detect latent residual contraction function in patients (pts) with idiopathic dilated cardiomyopathy. DESIGN: retrospective study in pts referred for cardiac catheterization. SETTING: Haemodynamic Laboratory of Cardiology Service, Bellvitge Hospital. Barcelona, Spain. PATIENTS: the criteria for including pts with sinus rhythm were (SR): 1-The appearance of an extra beat R' on the ventriculogram; 2-The location of R' in relation to the preceding sinus beat R1 and the following beat R2 being such that R1-R' less than R'-R2. In patients with atrial fibrillation (AF), the criteria were: 1-An early beat Re had to be identified; 2-R1-Re interval had to be at most half of the Re-R2 interval; 3-The length of the cardiac cycle preceding R, has to be equal to the mean cycle length. All the patients with an increase of the ejection fraction (EF) from R, to R2 less than 12% were included in group A: 12 patients (3 females, 9 males, mean age 51 years, 5 SR, FE 27 +/- 10%). In group B were included patients with an increase of the ejection fraction greater than or equal to 12%; 14 patients (4 females, 10 males, mean age 50 years, 7 SR, FE = 31 +/- 7%). MEASUREMENTS: In each ventriculogram we assessed the performance of left ventricle on R1 and R2 beats by determining: 1-Left ventricular end diastolic (EDV), end systolic (ESV), stroke (SV) volumes; 2-Volumes index (EDVI), (ESVI) (SVI); 3 - Ejection fraction (EF) - Change in ventricular contractility from R1 to R2, delta EF. RESULTS: in the sinus rhythm group the values of R1 and R2 were respectively: EDV: (184 +/- 48 ml/m2; 191 +/- 17 ml/m2; NS); SVI (53 +/- 19 ml/m2; 80 +/- 22 ml/m2; p less than 0.01) FE (29 +/- 7%; 42 +/- 10%; p less than 0.01), delta EF 13 +/- 6%. The change of the ejection fraction from R1 to R2 in pts with SR and AF were respectively: 13 +/- 6% and 11.5 +/- 6.4%; NS. Group A: Deterioration of the functional class and two deaths occurred. Group B: Improvement in functional class in all cases but one. CONCLUSION: our data suggest that augmented ventricular filling and consequent Starling's effect is not a significant contribute for PESP in pts with dilated cardiomyopathy. The analysis of post extrasystolic beat in SR pts and the beat following an early beat with a long diastole in AF, is a valuable method of determining the residual left ventricular function in this group of pts.

Cardiomyopathy, Dilated↗

[Automatic reading of ABO and Rh groups on microplates using FMC medium and an IBG Systems reader].

We present in this paper our experience in the routine use of an automatic reader for microtiter plates (IBG Systems). A total of 2044 samples from blood donors have been tested for ABO (haematic and seric) and Rh (D antigen) blood group typing. The red blood cell samples have been tested against monoclonal anti-A, anti-B, anti-AB and anti-Rh 1 (D) sera (using two different anti-D reagents). As a negative control, 3% albumin solution was employed. In order to determine the seric groups, the plasma samples were tested against A1, A2, B and 0 cells. In all cases the red cells were suspended in Ficoll 400R-Methyl cellulose (FMC), and 0.01 Bromelin was added to red blood cell samples to be typed. The obstacles in the automatic readings were mainly solved by visual reading of the microplates. In the 2,044 samples analysed with the automatic reader, 19 discrepancies (0.94%) were found in ABO typing. In all cases the error was in the seric blood group. Three false positive reactions were found with 0 red cells. Two false negative with B red cells, interpreted by the automatic reader as doubtful results. Three positive readings were detected, in one case the positivity was due to alloantibodies (C + D specificities), the other two cases were autoagglutinations. False negative reactions were found, in 11 cases, 8 of them due to lipaemia and the remaining three were haemolysed plasma samples. It should be stressed that out of 19 cases of discrepancy, only 5 (0.24%) were due to the automatic reader while the remaining were due, to sample troubles.(ABSTRACT TRUNCATED AT 250 WORDS)

ABO Blood-Group System↗

[Pulmonary edema secondary to acute obstruction of the upper airways. Apropos of a case of immediate recovery].

The AA. inform on the case of a girl, 13, carrying an aortic prosthesis who some hours after the removal of a laryngeal dilator had an asphyctic syndrome during a meal. The emergency being overcome an acute pulmonary edema could be diagnosed without either objective valvular or left ventricular dysfunctions. In spite of the prior heart pathology the reporters belief in the coincidence of the case displayed with a pulmonary edema following the acute obstruction of the upper respiratory tract. They review the proposed physiopathological hypothesis as well as the Spanish literature upon the subject.

Adolescent↗

[Use of FMC macromolecular medium for determination of the erythrocyte ABO group using microtiter plates].

Several blood group determination techniques have been developed in recent years which provide easy handling, fine reproducibility and similar or even higher sensitivity than the procedures commonly employed, aimed to be used in the automation of blood bank work. A microtitration plate technique for ABO determination on red cells is presented in this report. A macromolecular medium, comprised of a mixture of the polymers Ficoll 400 and carboxymethyl cellulose (FMC) is used ad coadjuvant for the reaction. This medium increases by 15- the score units and by 4-fold (or more) the intensity of haemagglutination (titration) in typing the ABO antigenicity of red cell A, B, O and AB groups.

ABO Blood-Group System↗

[Comparative studies of diatrizoate, ioxaglate and iohexol as angiocardiographic contrast media].

We did 2 consecutive randomized studies to compare the effects of diatrizoate, ioxaglate, and iohexol. Sixty patients were studied: 15 with diatrizoate (group I) versus 15 with ioxaglate (IIA), and 15 with ioxaglate (IIB) versus 15 with iohexol (III). Group I had hypotension and severe increase in end-diastolic pressure. Severe bradycardia was seen in 27% of the cases. Group IIA and IIB had identical changes, with a moderate increase in systolic and end-diastolic pressure. Group III only presented a mild increase in end-diastolic pressure. None of the low-osmolar contrast media produced severe bradycardia, but ioxaglate induced frequent (20%) nausea. Our results suggest the best contrast media for angiocardiography is, in decreasing order: iohexol, ioxaglate, and diatrizoate.

Angiocardiography↗

[Thyroplasty in the treatment of functional or paralytic dysphonias].

In phonosurgery, the laryngeal framework surgery, with several types of thyroplasty, allow a modification of the vocal function through an indirect action over the thyroid cartilage, without surgical invasion of the vocal fold tissues. We describe our experience and review the literature in this field.

Adult↗