PubMed Health⌕ Search

Biomedical subjects

J Meyer

Publications and source records attributed to J Meyer.

At least 397 records · Page 22Linked to original sources

Circadian rhythm photic phase shifts are not altered by histamine receptor antagonists.

Histamine may play a role in synchronizing endogenous circadian rhythms with exogenous photic cues. Direct application of histamine to the suprachiasmatic nucleus, the site of the mammalian circadian pacemaker, phase shifts the circadian rhythm in neural activity [7]. Intraventricular injections of histamine also phase shift circadian rhythms [14]. The magnitude and direction of the phase shifting effects of histamine depend on circadian phase in a manner similar to light [7,14]. Depletion of brain histamine levels by inhibition of histamine synthesis reduces phase shifts to light [10].

Animals↗

Duration estimates and users' preferences in human-computer interaction.

Two experiments assessed the effect of various static and dynamic computer 'wait' message displays on (1) subjective estimates of the duration of intervals during which a subject had to wait for the computer's response, and (2) subjective preferences among the different displays. All the static displays led to identical duration estimates. For dynamic displays a direct relation between the rate of changes and the estimate was found. Faster rates led in most cases to increased estimates of duration, and slow-changing graphic displays appeared to have the shortest duration. Subjects preferred epigrams to all other displays, and cumulative graphic displays to a blinking or static WAIT. The rate of change did not affect preference ratings for the graphic displays, whereas slower blink rates were preferred for the WAIT. The results demonstrate that the findings and models from earlier basic research on time estimation are relevant for predicting the subjective assessment of wait-periods. However, users' satisfaction with the displays depends not only on the apparent duration of the wait period, but also on other variables. These should be considered when choosing the display that is shown while users wait for the system to complete a task.

Adult↗

The influence of Albunex on the pulmonary circulation in patients with pulmonary hypertension or left heart failure.

To determine the safety of the ultrasound contrast agent Albunex, its influence on right and left heart haemodynamics in patients with pulmonary artery hypertension or left heart failure was assessed after intravenous injection. Patients with a left ventricular ejection fraction smaller than 40% or a systolic pulmonary artery pressure greater than 40 mmHg received 0.08 and 0.22 ml.kg-1 Albunex and 10 ml albumin in random order during right heart catheterization and transthoracic echocardiography. Right atrial, systolic and diastolic pulmonary artery and capillary wedge pressures were measured at 3 min and 5 min and cardiac output at 5 min after the intravenous injection of Albunex and control. The mean differences of pre- and postinjection values and their confidence intervals were tabulated and significance was anticipated if the confidence interval did not include 0. Significant changes to pre-injection values could be observed in diastolic pulmonary artery pressure 5 min after the injection of albumin and 0.08 ml.kg-1 Albunex, and in right atrial pressure 5 min after the injection of 0.22 ml.kg-1 Albunex only. Since intermediate opacification of the left ventricle was seen in only four patients with 0.22 ml.kg-1 Albunex, in the patients studied higher doses of Albunex and their safety need to be assessed.

Albumins↗

Differences in the morphology of unstable and stable coronary lesions and their impact on the mechanisms of angioplasty. An in vivo study with intravascular ultrasound.

The aim of this study was to compare the morphology of stable and unstable coronary lesions using intravascular ultrasound in patients undergoing coronary balloon angioplasty and to determine whether lesion morphology had any influence on the mechanism of balloon angioplasty. Thirty three (15 stable and 18 unstable) patients undergoing single lesion percutaneous transluminal coronary angioplasty were studied with intravascular ultrasound before and after intervention. All examinations, recorded on S-VHS video tape, were studied off-line and matched sites from the point of minimum lumen area after the procedure and the corresponding site prior to intervention were compared. The morphology of lesions before intervention was noted and the mechanisms of angioplasty (vessel stretch, lesion remodelling and lesion tears) were determined by comparing pre- and post-interventional morphology and dimensions. The only significant morphological difference between stable and unstable lesions was the presence of a demarcated inner layer in unstable lesions, delimited by a fine circumferential line. This pattern was noted in 77% (14/18) of unstable lesions and in 7% (1/15) of stable lesions (P < 0.01). Unstable lesions tended to have more echolucent zones than stable lesions (72% (13/18) vs 46% (7/15), P = 0.13). The mechanisms of angioplasty were also found to differ. Whereas lesion remodelling (or 'compression') was seen in 77% (14/18) of unstable lesions, it occurred in only 13% (2/15) of stable lesions and mean lesion cross-sectional area reduction was greater in unstable lesions, - 14.8 +/- 8.3% (2.1 +/- 1.3 mm2) compared to stable lesions, - 4.1 +/- 8.4% (0.42 +/- 0.9 mm2), P < 0.01. In contrast, vessel stretch was seen more frequently in stable lesions (73%, 11/15) compared to unstable lesions (22%, 4/18) P < 0.01 and the mean increase in vessel cross-sectional area was + 13.5 +/- 6.8 (1.6 +/- 0.9 mm2) in stable lesions compared to + 5.5 +/- 5.6% (0.8 +/- 0.9 mm2) in unstable lesions, P < 0.01. Lesion tear was present to a similar degree in both groups of patients. In this observational study we found a set of echographic markers that distinguished unstable lesions. The mechanisms of angioplasty differed between stable and unstable angina, with greater lesion remodelling seen in unstable lesions and vessel stretch in stable lesions. Taken together, these findings suggest that the markers we describe may be echographic indicators of mural thrombus.

Angina Pectoris↗

Value of intracoronary ultrasound and Doppler in the differentiation of angiographically normal coronary arteries: a prospective study in patients with angina pectoris.

BACKGROUND: A substantial proportion of patients undergoing heart catheterization for suspected coronary artery disease have normal angiograms. Coronary morphology and blood flow velocity can be assessed very accurately with intracoronary ultrasound and Doppler. The purpose of this study was to use both methods to classify further patients with suspected coronary artery disease but with coronary angiograms adjudged normal at the time. METHODS AND RESULTS: In forty-four patients with suspected coronary artery disease and normal coronary angiograms, intracoronary ultrasound and intracoronary Doppler were performed in the left anterior descending and left main coronary arteries. Coronary flow reserve was obtained by calculating the ratio of the maximal coronary flow mean velocity after the intracoronary administration of 10 mg papaverine to the coronary flow mean velocity at rest. Of 44 patients, 16 (36%) (group I) were found to have normal coronary morphology by intracoronary ultrasound and normal (> 3.0) coronary flow reserve (5.3 +/- 1.8). In seven patients (16%) (group II) there were normal intracoronary ultrasonic findings but a reduced coronary flow reserve (2.1 +/- 0.4). Plaque formation was found in a total of 21 (48%) of the 44 patients; mean plaque sizes were 3.6 +/- 1.6 mm2 for those in group III (normal coronary flow reserve) and 5.0 +/- 2.3 mm2 for those in group IV (reduced coronary flow reserve). Vessel area in both of these groups (16.3 +/- 8.0 mm2 and 19.2 +/- 6.1 mm2) was significantly larger than that of group I (14.6 +/- 5.7 mm2, P < 0.01). Plaque calcification was found in 25% of those in group III and 44% of those in group IV. Thus, only 36% of the patients with normal angiograms were true normal, 48% exhibited early stage of coronary atherosclerosis, and the other 16% might be considered as syndrome X. CONCLUSION: Intracoronary ultrasound and Doppler can be used to differentiate further heart disease in patients with normal coronary angiograms. Only a minority were true normal. Early signs of atherosclerosis cannot be detected by coronary angiography. This may have important therapeutic and prognostic implications.

Adult↗

Angiographic follow-up results of a randomized study on angioplasty versus bypass surgery (GABI trial). GABI Study Group.

Although several randomized trials have been performed to compare the outcomes of percutaneous transluminal coronary angioplasty (PTCA) and coronary artery bypass surgery (CABG) in patients with multivessel disease, there is little data available on angiographic follow-up results. The present substudy of the German angioplasty versus bypass surgery investigation (GABI Trial) compares the angiographic revascularization status in these two cases 6 months after treatment. Follow-up angiograms were available in 102 CABG patients and 117 PTCA patients. Although the protocol excluded patients with total occlusion, on follow-up 6 months after treatment we found total occlusion of 94 native arteries (36.9%) in the CABG group and of six arteries (2.5%) in the PTCA group (P < 0.001). The rate of occluded native vessels did not correlate significantly with the severity of the lesion before bypass surgery. In the CABG group 31 bypass grafts (12.2%) were found to be occluded at the 6 month follow-up examination (29/225 vein grafts [12.9%]; 2/30 mammary artery grafts [6.7%]). The main pathway, defined as the nutrient vessel (native vessel or bypass graft) providing the least resistance to blood flow, was narrowed by a lesion with a diameter stenosis of 70-100% for 36 target lesions (14.1%) in the CABG group and 39 target lesions (16.2%) in the PTCA group (P, ns). However, the prevalence of moderately severe lesions with a 50-69% diameter reduction of the main pathway was significantly greater in the PTCA group (44 lesions, 18.3%) than in the CABG group (19 lesions, 7.5%, P < 0.01). Thus, 6 months after randomized allocation to PTCA or CABG, we found comparable rates of high-grade lesions in the main pathways of both treatment groups. Whereas moderately severe lesions of the main pathway were predominantly seen in the PTCA group, there was marked disease progression to total occlusion in the native circulation after bypass grafting.

Aged↗

Recombinant hirudin as a periprocedural antithrombotic in coronary angioplasty for unstable angina pectoris.

Percutaneous transluminal coronary angioplasty is often complicated by thrombotic abrupt vessel closure in patients with unstable angina pectoris. The present multicentre trial was performed to determine the feasibility of two-dose regimens of recombinant hirudin (r-hirudin) compared to standard heparin in patients undergoing coronary angioplasty for unstable angina, and to investigate the effects of the different treatment regimen on markers of coagulation activation. At five participating centres, 61 patients were randomly enrolled in one of two sequential groups of r-hirudin (group 1: 0.3 mg.kg-1 i.v. bolus, 0.12 mg.kg-1.h-1 i.v. infusion; 21 patients; group 2: 0.5 mg.kg-1 i.v. bolus, 0.24 mg.kg-1.h-1 i.v. infusion; 19 patients) or in a heparin control group (150 IU.kg-1 i.v. bolus, 20 IU.kg-1.h-1 i.v. infusion; 21 patients). Antithrombotic therapy was started immediately before coronary angioplasty and continued for 24 h. This was followed by a low-dose anticoagulant infusion for another 24 h (r-hirudin: 0.04 mg . kg-1 . h-1; heparin: 7 IU . kg-1 . h-1). Activated partial thromboplastin time, r-hirudin plasma concentrations by both immunological and functional assay, thrombin-hirudin complex, thrombin-antithrombin III complex, soluble fibrin, and prothrombin fragment 1 + 2 were closely monitored. The median partial thromboplastin time prolongations at 24 h vs baseline were found to be 1.9-fold and 2.3-fold in r-hirudin group 1 and dose group 2, respectively, and 3.0-fold in the heparin group. There was a dose-dependent correlation between partial thromboplastin time and the r-hirudin plasma levels (r = 0.61). In five of 21 patients of dose group 1, three of 19 patients of dose group 2, and 10/21 patients of the heparin group, partial thromboplastin time values exceeding the predefined target range prompted an interruption of the infusion. One major bleeding complication occurred in dose group 2. The functional assay for the estimation of r-hirudin plasma concentrations showed excellent correlations to the immunological technique (r = 0.99). Differences between the thrombin-hirudin complex levels could not be observed. Increased concentrations of thrombin-antithrombin III complex, soluble fibrin, and prothrombin fragment 1 + 2 were seen 4-8 h after coronary angioplasty and after reduction of the high-dose therapy in dose group 1 when compared with dose group 2 and the heparin group, respectively. Based on coagulation tests the present study showed the feasibility of a periprocedural antithrombotic regimen with r-hirudin for patients undergoing coronary angioplasty for unstable angina. In addition to the partial thromboplastin time the determination of r-hirudin plasma levels by a chromogenic substrate assay considerably improves the monitoring of therapy. The lower dose r-hirudin regimen seems to be suboptimal as periprocedural anticoagulation in coronary angioplasty patients as indicated by markers of thrombin generation and thrombin activity.

Adult↗

Unilateral spinal anesthesia using low-flow injection through a 29-gauge Quincke needle.

Restriction of sympathetic denervation during spinal anesthesia may minimize hemodynamic alterations. Theoretically, the use of nonisobaric anesthetics may allow unilateral anesthesia and thus restrict sympathetic denervation to one side of the body. The present prospective study investigates the incidence of unilateral spinal anesthesia using hyperbaric bupivacaine 0.5% (1.4 mL, 1.6 mL, 1.8 mL, or 2.0 mL) injected via a 29-gauge Quincke needle with a pump-controlled injection flow of 1 mL/min. In 96 consecutive patients undergoing unilateral surgery of the lower extremities, spinal anesthesia was performed in the lateral decubitus position, which was maintained for 20 min postinjection. Increases in foot temperature of at least 0.5 degrees C were defined as sympathetic blockade. The incidence of unilateral block was not significantly influenced by the amount of bupivacaine. For all 96 patients, the incidence of unilateral sympathetic and complete motor block was 69% and 77%, respectively. Frequency of unilateral sensory block (assessed by pinprick and temperature discrimination) was significantly lower (28%). Strict unilateral spinal anesthesia was achieved in 24 cases (25%). Twenty minutes after injection of the local anesthetic, mean arterial blood pressure decreased significantly in patients with bilateral sympathetic blockade from 87 +/- 8 to 83 +/- 8 mm Hg (P < 0.01) but not in patients with unilateral sympathetic blockade (from 87 +/- 11 to 85 +/- 10 mm Hg). In conclusion, low-flow injection (1 mL/min) of hyperbaric bupivacaine 0.5% via a 29-gauge Quincke needle prevented bilateral sympathetic blockade in more than 69% of the patients. The data further suggest that loss of temperature discrimination alone is not a reliable estimation of sympathetic block.

Anesthesia, Spinal↗

Nitric oxide synthase inhibition restores vasopressor effects of norepinephrine in ovine hyperdynamic sepsis.

To investigate the hypothesis that nitric oxide synthase (NOS) inhibition restores the vasopressor response to norepinephrine (NE) in ovine hyperdynamic sepsis, eight sheep were chronically instrumented. In the non-septic portion of the study, NE was titrated to achieve an increase in mean arterial pressure (MAP) by 15 mm Hg ("small dose"). Small-dose NE was repeated 1 h after administration of the NOS inhibitor NG-nitro-L-arginine methyl ester (L-NAME; bolus 5 mg/kg, followed by 1 mg.kg-1.h-1). After 3 days of recovery, sepsis was induced by a continuous endotoxin infusion (Salmonella typhosa, 10 ng.kg-1.h-1). Three animals died during this period (data excluded). After 24 h, small-dose NE was given. If MAP increased less than 15 mm Hg, the NE dose was increased to achieve the targeted MAP change ("large dose"). Finally, both doses of NE were given after L-NAME administration. To increase MAP by 15 mm Hg in nonseptic animals, the rate of NE infusion was 0.18 +/- 0.03 microgram.kg-1.min-1 (small dose). During L-NAME infusion, this NE dose increased MAP by 32 +/- 8 mm Hg. In septic animals, small-dose NE increased MAP by only 9 +/- 2 mm Hg (P < 0.05 versus nonseptic state). To increase MAP by 15 mm Hg, the NE dose had to be increased to 0.34 +/- 0.06 microgram.kg-1.min-1 (large dose). During L-NAME infusion, NE administration increased MAP by 16 +/- 2 mm Hg and 28 +/- 4 mm Hg (small and large dose, respectively). Thus, L-NAME restored the vasopressor response to NE in sepsis, and increased the vasopressor response to NE in a similar fashion in healthy and septic sheep.

Animals↗

Increased plasma concentration of fibrin monomer in acute myocardial infarction with early reperfusion.

OBJECTIVE: To assess whether plasma fibrin monomer (FM) concentration, a marker of thrombin activity, is increased in the first hours after acute coronary occlusion and whether there are differences between patients with and without early reperfusion. DESIGN: Thirty-five consecutive patients with acute myocardial infarction (AMI) and early coronary angiography were studied prospectively. METHODS: Plasma FM samples taken on admission (< 6 h after onset of chest pain) and 6-14 h after onset of chest pain were analysed using a specific enzyme immunoassay. All of the patients were anticoagulated with heparin intravenously. RESULTS: Of the 35 patients, 28 had angiographically documented reperfusion within the first 6 h, whereas seven patients had no early reperfusion. FM concentrations were measured in the reference range (< or = 3.6 mg/l) within the first 6 h in 32 of the 35 patients. At 6-14 h FM concentrations were elevated in the reperfusion group (median 4.56 mg/l), but not in the group without reperfusion (median 1.6 mg/l, P = 0.0063). Using a threshold value of 3.0 mg/l, sensitivity and specificity of FM for the non-invasive recognition of early reperfusion were 78 and 83%, respectively. The specificity was similar to that for troponin T and higher than the creatinine kinase MB specificity. CONCLUSIONS: FM plasma concentrations are elevated in patients with AMI and early reperfusion. With a single blood sample 6-14 h after onset of chest pain, FM analysis is useful for the non-invasive detection of early reperfusion after AMI.

Anticoagulants↗

Evaluation of post-myocardial infarction regional and global left ventricular function by monoplane ventriculography: superiority of right versus left anterior oblique projection at any infarct location.

OBJECTIVES: To study the significance of serial quantitative regional wall motion analysis, volumes, and ejection fraction findings as well as their prognostic implications derived from cineventriculography in 30 degrees right anterior oblique (RAO) projection in comparison with 60 degrees left anterior oblique (LAO) projection in post-myocardial infarction patients. Ventriculographic left ventricular parameters are accepted surrogates of mortality in myocardial infarction. Nowadays, in contrast to a biplanar approach in most institutions and clinical trials, the investigation is reduced to monoplanar ventriculography. However, it is not known whether the relevance of the two established projections might differ in different infarct topographies. DESIGN AND METHODS: Two hundred and six consecutive patients with acute myocardial infarction (infarct duration < 6 h) were treated with streptokinase (group I, n = 103) and allocated randomly additional percutaneous transluminal coronary angioplasty (group II, n = 103). Biplanar cineventriculography studies were performed at the acute stage, before discharge, and 6 months after discharge from hospital. RESULTS: Regional wall motion analysis (using an algorithm of fixed radiants) documented larger hypokinetic areas and intensities on RAO than it did on LAO projections, whereby infarct size and its improvement (stunned myocardium) was displayed more comprehensively, and a higher predictive power for survival (P = 0.0002 versus NS) was shown in anterior and inferior infarcts. No advantage of the LAO projection could be detected for evaluation of lateral infarcts due to circumflex coronary artery thrombosis either. The predictive power of the global function (ejection fraction; the algorithm of disc summation method) established by RAO projection (P = 0.007) was superior to that of LAO projection (P = 0.03). Enlargement of volumes (left ventricular remodeling) could be documented significantly only by the RAO projection; the LAO projection failed to do so. Groups I and II did not differ in any respect. CONCLUSIONS: The RAO projection has excellent diagnostic and predictive power at any infarct location. In contrast, additional LAO projection provides little information that cannot be obtained reliably from the RAO projection.

Angioplasty, Balloon, Coronary↗

The genetics of children's oral reading performance.

Measures of reading achievement and verbal ability have been shown to be heritable. Additionally, recent evidence has been suggestive of a major gene effect on reading disability and for problem reading in a sample of normal readers. We report on the etiology of individual differences in oral reading performance, the Slosson Oral Reading Test (SORT), for which biometrical analyses have not been reported in the literature previously. Oral reading performance was measured in a large population-based sample of twins of the Virginia Twin Study of Adolescent Behavioral Development. Biometrical analyses of the SORT suggested that, in both males and females, 69% of the phenotypic variation was due to heritable influences and 13% of the variation due to shared environmental effects. While the relative importance of genetic and environmental influences is equivalent for males and females, males showed greater phenotypic variability than females.

Achievement↗

Genetic and environmental influences on the covariation between hyperactivity and conduct disturbance in juvenile twins.

Structural equation models were applied to the maternal ratings of 265 MZ and 163 DZ male-male, 347 MZ and 160 DZ female-female, and 262 male-female twin pairs, aged 8-16 years, who participated in the Virginia Twin Study of Adolescent Behavioral Development (VTSABD). Substantial additive genetic influences and contrast effects were found for hyperactivity, and additive genetic and shared environmental effects or positive comparison effects (particularly for the girls) for oppositional/ conduct disturbance. Bivariate model fitting showed that the covariation between hyperactivity and oppositional/conduct problems in both younger and older boys and girls is almost entirely attributable to genetic factors. However, whereas in the younger males and females the same set of genes explain all the variation in hyperactivity and conduct disturbance, in the older cohort at least some of the genetic effects are behavior- and gender-specific.

Adolescent↗

Is there a risk for interaction between mobile phones and single lead VDD pacemakers?

Mobile phones may cause pacemaker interference. Patients with a single lead VDD pacemaker might be at special risk, since the atrial sensitivity is often programmed to low (high sensitivity) threshold values and the majority of patients are pacemaker dependent due to the underlying high degree AV block. We evaluated 31 patients with three types of single lead VDD pacemakers: 12 Unity, 292-07 (Intermedics, Inc.); 10 Thera VDD, 8948 or 8968i (Medtronic, Inc.); and 9 Saphir 600 (Vitatron, Inc.) for interference from a cellular mobile phone with a power of 2 W (D-net). For this purpose, atrial and ventricular sensitivity settings were programmed to their most sensitive values (A: 0.1-0.25 mV; V: 1.0 mV) and ventricular sensing was programmed to unipolar. With the ECG continuously monitored, the phone's extendable antenna was brought in direct contact with the patient's skin at the right sternal border, with the tip of the antenna in skin contact just below the clavicle, within 5 cm of the pacemaker connector. Then multiple phases of phone calls were performed, and the effects on the pacemakers recorded. In our group of patients with three different types of single lead VDD pacemakers, no interference could be detected using a 2-W mobile phone in the digital D-net. The programmed values remained unchanged after the interference test. Therefore, the risk of interference seems to be low for the VDD pacemakers tested, although our study design does not allow to entirely exclude the possibility of interference from a mobile phone.

Cardiac Pacing, Artificial↗

Holter recordings with continuous marker annotations: a new tool in pacemaker diagnostics.

UNLABELLED: Pacemakers provide marker annotations to facilitate the interpretation of pacemaker electrocardiograms (ECGs) and can be used in cases of suspected pacemaker malfunction or to understand pacemaker behavior. Due to the need for a programmer, only short-term evaluations are possible. We evaluated a prototype Telemetry Data Logger (TDL) designed to continuously transfer markers from the pacemaker to a conventional Holter recorder. A miniaturized telemetry receiving coil was attached to patient's skin above the pacemaker, which was programmed to transmit markers continuously. The TDL, which receives and converts markers into eight positive and eight negative deflections, ranging from -2.5 to +2.5 mV in amplitude, was connected to one channel of a conventional Holter recorder (Tracker 2). We performed 20 Holters in 13 patients who had implanted VDDR or DDDR devices from the same manufacturer and evaluated three versions of software. Marker transmission was possible in all patients, producing Holter ECGs with complete marker annotations. Artifacts occurred < 4% of the time. A 50-ms rectangular pulse was optimal for marker interpretation. The device, which was easy to use and well accepted by the patients, assisted in the diagnosis of inappropriate pacemaker programming, even when the surface ECG seemed to show regular pacemaker function. In the presence of low quality surface ECGs, marker annotations allowed the assessment of pacemaker function. The capability to annotate the onset of special algorithms, like tachycardia termination algorithms or mode switching, facilitates interpretation of pacemaker behavior, enabling a reliable assessment of the appropriateness of such algorithms. CONCLUSION: The TDL effectively enables pacemaker markers to be inscribed onto a conventional Holter recording, facilitating the interpretation of pacemaker ECGs and the diagnosis of inappropriate pacemaker programming even when not discernible from the surface ECG alone.

Algorithms↗

A simple method for preoperative assessment of the best fitting electrode length in single lead VDD pacing.

For single lead VDD pacing, electrodes with various distances between the lead tip and the floating atrial dipole (AV distance) are available. Using different AV distances allows positioning of the atrial dipole in the mid- to high right atrium, regardless of the size of the right heart. In this position, reliable atrial sensing and rejection of ventricular far-field potentials can be expected. A simple test for the preoperative assessment of the best fitting AV distance in the individual patient was tested. We studied 24 consecutive patients prior to implantation of a VDD pacemaker. With the patient in supine position, a test electrode with an AV distance of 13 cm was taped onto the thorax. Under fluoroscopic control, it was moved until its course and projection onto the heart was equal to that of a ventricular lead. If fluoroscopy then showed a projection of the atrial dipole onto the mid- to high right atrium, a lead with a similar AV distance of 13 or 13.5 cm was used for implantation. If the atrial dipole projected itself too high or too low, a shorter or longer lead had to be implanted. The maximum time for the test was 2 minutes, and the maximum fluoroscopy time was 15 seconds. According to the test, a lead with an AV distance of 13 or 13.5 cm was implanted in 18 of 24 patients, and a lead with an AV distance of 15.5 or 16 cm was implanted in 6 of 24 patients. The atrial dipole could easily be positioned in the mid- to high right atrium in all patients, demonstrating a correct preoperative assessment of the best fitting AV distance. Intraoperatively, a P wave amplitude of 3.5 +/- 3.0 mV was measured. The described test allows a fast and reliable assessment of the best fitting electrode length in single lead VDD pacing.

Adult↗

Cardiac output is not affected during intraoperative testing of the automatic implantable cardioverter defibrillator.

INTRODUCTION: Perioperative mortality of patients undergoing implantation of automatic implantable cardioverter defibrillators (ICDs) has been reduced dramatically following the availability of transvenous-subcutaneous defibrillation leads. However, patients with severely reduced left ventricular function show a substantial rate of nonsudden cardiac mortality within the first year. Whether repeated intraoperative inductions of ventricular tachycardia/fibrillation (VT/VF) during implantation lead to hemodynamic deterioration and thus might contribute to development of end-stage heart failure in these patients is unknown. The purpose of the present study was to determine cardiac output and hemodynamic performance during transvenous-subcutaneous ICD implantation in patients with severe left ventricular dysfunction. METHODS AND RESULTS: In 11 patients with a left ventricular ejection fraction (EF) < or = 0.35, cardiac output was measured automatically with a combined continuous cardiac output/mixed venous oxygen saturation pulmonary artery catheter system. ICD implantation was performed during standardized general anesthesia. In the 11 patients (EF = 27 +/- 2% [mean +/- SEM]) a total of 95 episodes of VT/VF followed by defibrillation were induced (episodes per patient = 9 +/- 1; range 6 to 11). Cardiac index was 2.2 +/- 0.2 L.min-1.m-2 after induction of anesthesia (before start of surgery), and 1.9 +/- 0.1 L.min-1.m-2 immediately before first induction of VT/VF. After the last episode of VT/VF, cardiac index was 2.1 +/- 0.2 L.min-1.m-2. Cardiac index measured 1, 2, and 3 minutes after induction of VT/VF was not significantly different when compared to the preinduction value during any episode of VT/VF induction. Similarly, stroke volume index was 39 +/- 5 mL.m-2 immediately before first induction of VT/VF and 36 +/- 3 mL.m-2 after the last episode of VT/VF (NS). At the end of surgery, hemodynamic parameters did not exhibit any significant difference when compared to the data obtained before start of ICD implantation and testing. CONCLUSION: Extensive defibrillation tests during transvenous-subcutaneous ICD implantation in patients with severe left ventricular dysfunction are not associated with acute deterioration of cardiac performance.

Cardiac Output↗