PubMed Health⌕ Search

Biomedical subjects

J Middleton

Publications and source records attributed to J Middleton.

At least 37 records · Page 2Linked to original sources

An evaluation of the stresses generated in a bonded orthodontic attachment by three different load cases using the Finite Element Method of stress analysis.

The objective of the investigation was to develop a clinically valid three-dimensional computer model of the orthodontic bracket-cement-tooth continuum, and determine the magnitude and distribution of stresses generated by three different load cases. A three-dimensional finite element model of the bracket-cement-tooth system was constructed consisting of 15,324 nodes and 2,971 finite elements. The stresses induced in the bracket-tooth interface by a masticatory load, a peel force and a twisting couple were recorded. The maximum principal stresses resulting from occlusal and 'twisting' forces are distributed toward the lute periphery. Peel forces, applied to the bracket tie wing, are concentrated beneath the bracket stem. Twisting forces result in the highest enamel stresses. The quality of orthodontic attachment can be explained by the magnitude and distribution of major principal stresses within the cement and impregnated bracket base. Shear and shear/peel forces are most likely to induce crack propagation within the adhesive layer. However, when a twisting action is used to remove orthodontic brackets, enamel failure is most likely. A clearer insight into the complexity of the bracket-cement-tooth system has been provided by numerical and finite element investigations. Further investigations, evaluating the influence of bracket base designs and orthodontic cement physical and geometric properties are indicated. Refereed Scientific Paper

Compressive Strength↗

Asymptotic analysis of the stress field in adhering dental restorations.

Polymer-based composites are widely used in restorative dentistry as alternatives to metals and ceramics to fill cavities in teeth. They adhere to the walls of the cavity in the tooth, thus forming a composite body consisting of dentine, enamel, and composite resin. Geometric discontinuities along the interfaces between these materials can induce singularities in the stress field, which in turn lead to premature failure of the restoration. In the present investigation, a complex stress function technique is employed to derive the order of the stress singularity. It is shown that the order of the singularity depends on both the material properties of the restorative material and the local geometry of the cavity. It is also shown that the singularity in the stress field can be avoided through careful design of the cavity shape. The results presented correlate well with experimental results reported in the literature.

Cementation↗

The influence of bracket base design on the strength of the bracket-cement interface.

The objectives of the study were to isolate the bracket-cement interface, and to determine the influence of bracket base morphology and orthodontic bonding agent chosen on strength of adhesion. The bracket bases evaluated included 60, 80, and 100 single mesh bases, a double mesh base, and the Dynalock, and Mini Twin bases. The strength of interface provided by each of these bases with Concise, Transbond, Right On, and non-encapsulated Fuji Ortho LC cements, was measured in tension and recorded in Mega Pascals. The single-mesh bases performed well with either Concise or Right On (11*88-22*72 MPa) and, other than the 80-mesh bracket, relatively poorly with Transbond (2*18-5*15 MPa). With Fuji Ortho LC, the single mesh bases performed well (6*05-12*19 MPa). The double mesh base performed well with Right On (13*75 MPa), and reasonably well with Concise, Transbond, and Fuji Ortho LC (6*00-9*20 MPa). The Dynalock and Mini Twin Bases performed fairly well with all cements (8*87-17*16 MPa). It was concluded that the orthodontic bonding agent selected would appear to largely determine the bond strength achieved with a particular bracket base design. A definite trend was difficult to identify in this study, and it appeared that certain combinations of bracket base and bonding agent performed optimally. Particular base designs may allow improved adhesive penetration or improved penetration of curing light. Alternatively, the dimension and distribution of resin/cement tags prescribed by one base could promote a stress distribution that is better resisted by a particular adhesive.

Acrylic Resins↗

Numerical investigation of fixed orthodontic brackets.

This paper presents the results of investigations into the mechanical behaviour of fixed orthodontic brackets. Special attention has been paid to the detailed modelling of the interface between the bracket base and an adhesive by which attachment is made to the tooth surface. Properties of this interface were taken as design parameters with the aim of investigating their influence on the stress field induced during bracket removal at the end of the treatment. Stress-strain analysis was performed using a finite element program developed in-house.

Dental Cements↗

Accuracy of centre of pressure measurement using a piezoelectric force platform.

OBJECTIVE: To evaluate the accuracy in determining centre of pressure when using a force platform for stabilometry research. DESIGN: Technical report. BACKGROUND: Previous studies have determined the accuracy of locating the centre of pressure by applying force through a single point. In human stabilometry research however, force is distributed across two feet and the centre of pressure located between the feet. METHODS: Forces were applied to a Kistler force platform using a force applied through a single point as well as when force was distributed between two metal blocks. RESULTS: Errors in calculating centre of pressure were substantially larger when force was applied through a single point than when the force was distributed between two blocks. CONCLUSIONS: Evaluating centre of pressure accuracy by applying force through a single point overestimates the errors inherent in human stabilometry research. RELEVANCE: Evaluating changes in the centre of pressure of human subjects standing on a force platform is a common tool for evaluating control mechanisms of balance. Accurate information regarding the centre of pressure is essential for the validity of this research.

Biomechanical Phenomena↗

Changes in serum chondroitin sulphate epitopes 3-B-3 and 7-D-4 in early rheumatoid arthritis.

OBJECTIVES: The aims of the present rheumatoid arthritis (RA) study were (1) to examine the levels of serum 3-B-3 and 7-D-4 to find out whether they are different from controls, (2) to find out whether the concentrations of these epitopes change with disease duration in early RA and (3) whether the serum concentrations of 3-B-3 and 7-D-4 in early RA are prognostic for subsequent disease progression. METHODS: The concentrations of 3-B-3 and 7-D-4 in sera were quantitated by immunoassays. RESULTS: The levels of 3-B-3 and 7-D-4 were significantly lower in RA than in controls (3- to 30-fold, P < 0.001). Changes in 3-B-3 and 7-D-4 were apparent with disease duration. At first presentation, the 3-B-3 concentration was lowest and increased at 12 months (3-fold, P < 0.001). This increase was transient since by 24 and 36 months the concentrations were not different to those at first presentation. The level of 7-D-4 was also lowest when the patients first presented at clinic and increased with time at 6 months (2-fold, P < 0.001). The increase was more prolonged for 7-D-4, remaining elevated at 12, 24 and 36 months. The lack of correlations of serum 3-B-3 and 7-D-4 with clinical measurements showed that these markers were not prognostic for disease severity. CONCLUSIONS: The levels of 3-B-3 and 7-D-4 differed between RA and control sera, and changed with disease duration. These markers were not prognostic in predicting disease outcome.

Adult↗

Patient's lists.

Explore the source record for details and available documents.

Attitude of Health Personnel↗

Endothelial cell "memory" of inflammatory stimulation: human venular endothelial cells store interleukin 8 in Weibel-Palade bodies.

The expression and secretion of interleukin (IL)-8, the prototype member of the C-X-C subfamily of chemokines, can be induced by diverse inflammatory stimuli in many cells, including endothelial cells (EC). Upon de novo synthesis, IL-8 localizes intracellularly in the Golgi apparatus, from where it is secreted. In addition to this constitutive secretory pathway, we describe a depot storage and separate regulated secretory pathway of IL-8 in EC. The prolonged stimulation of primary human EC with inflammatory mediators resulted in the accumulation of IL-8 in Weibel-Palade bodies, where it colocalized with von Willebrand factor. IL-8 was retained in these storage organelles for several days after the removal of the stimulus and could be released by EC secretagogues such as phorbol myristate acetate, the calcium ionophore A23187, and histamine. These findings suggest that storage of IL-8 in Weibel-Palade bodies may serve as the EC "memory" of a preceding inflammatory insult, which then enables the cells to secrete IL-8 immediately without de novo protein synthesis.

Calcimycin↗

Mortality following spinal cord injury.

This study analyzed the mortality in 1453 spinal cord injured patients admitted early after injury to a specialised Spinal Injuries Unit within a University teaching hospital over a 40-year period. The cohort comprised 55.3% patients with cervical lesions and 44.7% patients with thoracic/lumbar lesions. Those patients who died within 18 months of the spinal injury (132) were excluded from the final analysis. Standardised Mortality Ratios, survival rates and life expectancy ratios were calculated for specific ranges of current attained age and duration since injury with reference to level and degree of spinal cord injury. The projected mean life expectancy of spinal cord injured people compared to that of the whole population was then estimated to approach 70% of normal for individuals with complete tetraplegia and 84% of normal for complete paraplegia (Frankel grade A). Patients with an incomplete lesion and motor functional capabilities (Frankel grade D) are projected to have a life expectancy of at least 92% of the normal population.

Adult↗

Pain and cognitive status in the institutionalized elderly: perceptions & interventions.

The purposes of this study were to examine the relationship between: (1) nurses' ratings of pain and corresponding administration of pain medication to elderly long-term care residents, and (2) cognitive status of the elderly and pain medication orders/administration. Participants were 83 residents, 60 years of age and older, in two groups: cognitively impaired (n = 64), and cognitively intact (n = 19). For comparison purposes, 19 of the cognitively impaired subjects were matched on age and diagnosis to provide control for potentially painful conditions. A retrospective medication review of the resident's charts was conducted to compare medication orders and administration on analgesics that were scheduled and p.r.n. (given as needed). The pain ratings of 25 RNs using a visual analogue scale were correlated with pain medications given to the resident on the day of the rating. Results indicated that RNs' ratings of resident pain and the administration of pain medications were not significantly correlated. In addition, cognitively impaired residents were prescribed significantly less scheduled medication and received significantly less pain medication (either p.r.n. or scheduled) than the cognitively intact elderly. Implications for practice and research are discussed.

Aged↗

Vibration perception threshold: are multiple sites of testing superior to single site testing on diabetic foot examination?

Vibration perception threshold (VPT) values, measured at different anatomic locations on the foot and ankle, and the time to assess VPT and sensory perception using two difference modalities in 102 diabetic patients were compared. VPT was evaluated at the great toe, fifth metatarsal and ankle. Differences in VPT at these three sites, in addition to differences in duration of testing comparing single site (great toe) to multiple sites, and to standard SWMF testing were assessed. No significant difference in VPT between the great toe and fifth metatarsal was found for patients both with and without loss of protective sensation (LOPS). Mean VPT was significantly higher at the ankle compared with both the great toes and fifth metatarsals. However, the difference between ankle and great toe was not significant between patients with and without LOPS [3.9 +/- 11.2 (12%) vs. 3.0 +/- 10.8 (16%) volts, respectively, p > 0.6]. Testing of one site took approximately half the time of Semmes-Weinstein 10-gram monofilament wire SWMF testing (40.5 +/- 16.9 vs. 22.3 +/- 9.1 seconds, p < 0.01) and less than one third the time of three-site VPT testing (10.5 +/- 26.1 vs. 22.3 +/- 9.1 seconds, p < 0.01). There may not be a significant practical benefit in multiple site VPT testing when compared with single site testing on the great toe alone. The value of multiple site testing is further called into question when one notes that the great toe VPT remains the only site tested for sensitivity and specificity for ulceration.

Diabetic Foot↗

Transcytosis and surface presentation of IL-8 by venular endothelial cells.

Chemokines have been convincingly implicated in actuating inflammatory leukocyte emigration. To affect the circulating leukocytes, tissue-derived chemokines have to traverse the endothelial cells (ECs). This was thought to be accomplished by chemokine diffusion through the intercellular gaps. On the contrary, we show by electron microscopy that the prototype chemokine IL-8 is internalized by venular ECs abluminally and transcytosed to the luminal surface. Here, it is presented to the adherent leukocytes on the EC membrane, predominantly in association with the EC projections. The intact C terminus of IL-8, the molecule's "immobilization" domain, is required for the EC binding, transcytosis, and consequently, the in vivo proemigratory activity of IL-8, indicating that the described subcellular interactions of IL-8 with the ECs are functionally relevant.

Animals↗

Neonatally wounded skin induces NGF-independent sensory neurite outgrowth in vitro.

An in vitro model was established to investigate factors underlying the sensory hyperinnervation of neonatal rat skin wounds that has been observed in vivo (Reynolds and Fitzgerald, J. Comp. Neurol. 358 (1995) 487-489). Explants of normal and wounded rat dorsal foot skin were co-cultured with explants of embryonic chick or newborn rat dorsal root ganglia for 24 h and the number of sensory neurites counted. Explants of skin surrounding a wound made at birth were taken 3 (P3) or 10 (P10) days later and compared with normal skin of the same age. In addition, explants were taken from adult skin wounded 3 and 10 days earlier. At P3, normal skin induced weak neurite outgrowth (mean 13.1 +/- 2.1 neurites per ganglion explant) but skin that had been wounded 3 days earlier, at birth, induced three times more neurite outgrowth (37.8 +/- 3.3). Ten days after wounding at birth, neurite outgrowth was still substantial (40.9 +/- 3.3) although at that age (P10), even normal skin stimulates substantial growth (37.4 +/- 2.9). Normal adult skin also stimulated neurite outgrowth (28.7 +/- 0.45) but this was not increased by wounding 3 or 10 days earlier, and this was enhanced 3 days but not 10 days after wounding. Anti-NGF (nerve growth factor) added to the culture medium blocked the constitutive neurite stimulating activity from normal P10 and adult skin but was ineffective in blocking the neurite stimulating activity produced by neonatal wounding. It is concluded that skin wounding at birth results in release of one or more sensory neurotrophic factors that stimulate rat and chick dorsal root ganglia neurite outgrowth for at least 10 days, but which do not include NGF.

Animals↗

Quantitative assessments of elbow flexor muscle performance using twitch interpolation in post-polio patients: no evidence for deterioration.

A large number of patients previously affected by polio have symptoms, including increased weakness and fatigue, which are collectively known as a post-polio syndrome. Prospective measurements of strength and endurance using twitch interpolation in post-polio patients are lacking and hence the exact rate of decline in muscle function in these patients is not well defined. We therefore measured performance of the elbow flexor muscles twice, at a mean of 2.5 years apart in a group of selected post-polio subjects (Group A, n = 13) and matched control subjects (n = 11), and in a second group of unselected polio patients from a post-polio clinic (Group B, n = 40) at a mean of 1.7 years apart. All subjects performed 10 attempted maximal voluntary isometric contractions of the elbow flexor muscles, during which voluntary activation of the elbow flexor muscles was measured using a sensitive form of twitch interpolation. The first group of selected polio subjects (Group A) and matched control subjects also performed 45 min of submaximal exercise. During this time, at 5-min intervals, maximal voluntary force, voluntary activation and the amplitude of twitch responses to single and paired stimuli were measured in order to investigate central and peripheral components of muscle fatigue. There was no change in the polio patients' strength, voluntary activation or peripheral muscle endurance between testing sessions, despite an 80% probability of detecting a 2.5% change per year in these variables. The unselected group of patients from the post-polio clinic (Group B) showed no change in maximal voluntary strength or voluntary activation between the first and second test. There was an absence of decline in muscle performance in these polio patients over the test interval, despite a subjective deterioration in muscle function consistent with the 'post-polio syndrome'. This supports the view that symptoms of the post-polio syndrome are not due to a progressive neuronal dysfunction.

Adult↗