PubMed HealthSearch

Biomedical subjects

J N Petersen

Publications and source records attributed to J N Petersen.

6 recordsLinked to original sources

Control and optimization of apheresis procedures in a COBE 2997 cell separator.

To obtain more efficient operation of a COBE Model 2997 clinical cell separator using either a Single Stage II (SS II) or a Dual Stage separation chamber, modifications were made to allow complete computer control. Product cell density was detected using an optical sensor and controlled by automatic feedback through a microcomputer interface. Control was accomplished by automatically adjusting the red blood cell (RBC) and plasma product flow rates using a proportional-integral (PI) algorithm. Results show that, using either chamber, the product cell density can be maintained at a preselected value for extended periods of time without operator intervention. This system allowed investigation of optimal operating regions for plateletpheresis and leukapheresis procedures. The effects of centrifuge rpm and controller set point on centrifuge operation were investigated using a second order factorial experimental design. Theoretical significance of model parameters was assessed with the aid of a hindered settling model and simple reasoning about the interface position relative to the collection port. The results suggest that, in either chamber, the optimum operating region for plateletpheresis procedures occurs at moderate controller set points and high centrifuge rpm. The resultant operating efficiency and product purity values are approximately 63 percent and 0.65 respectively in the SS II chamber and approximately 70 percent and 0.70 respectively in the Dual Chamber. In the SS II, the optimum operating region for leukapheresis procedures occurred at high controller set point values for any centrifuge rpm above 1200 with an operating efficiency near 100 percent. However, in the Dual Chamber, the optimum operating region for leukapheresis procedures occurred at high controller set points and high centrifuge rpm's, again providing an operating efficiency near 100 percent.

Animals

The effects of RPM and recycle on separation efficiency in a clinical blood cell centrifuge.

A COBE blood cell centrifuge, model 2997 with a single stage channel, was modified to allow computer controlled sampling, and to allow recycle of red blood cells (RBCs) and plasma streams using bovine whole blood. The effects of recycle of the packed RBC and plasma product streams, and of the centrifuge RPM on platelet and white blood cell (WBC) separation efficiencies were quantified using a central composite factorial experimental design. These data were then fit using second order models. Both the model for the WBC separation efficiency and the model for the platelet separation efficiency predict that RPM has the greatest effect on separation efficiency and that RBC and plasma recycle have detrimental effects at moderate to low RPM, but have negligible impact on separation efficiency at high RPM.

Animals

Interface dynamics in a centrifugal cell separator.

Experiments were performed with bovine blood to study the response of the plasma/cell interface position to pumping rate adjustments in two single-stage (SS I and SS II) cell separation chambers. Standard clinical instrumentation and equipment and on-line computer interfacing were used to monitor and control the interface position. The data provided a quantitative description of its dynamics in the SS I and the SS II chambers. In the SS I chamber, adjustments in the flow rate caused the interface to move very slowly and in a complex manner from one steady-state operation position to another. Such behavior made both manual and computer-controlled operation very difficult. By contrast, the SS II chamber was inherently unstable for most operating conditions. We demonstrated, however, that a feedback controller could be used easily to adjust or maintain the interface position, and this system moved from one steady-state operating condition to another 10 times as fast as the system using the SS I chamber. Also, the manner in which the controller allowed the system to respond to operator requests was much simplier than that for the SS I system.

Animals