Fish consumption and the risk of myocardial infarction.
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to J N Ruskin.
Explore the source record for details and available documents.
Transient and significant decrease in R wave amplitude, associated with transient right bundle branch block, was noted to occur after defibrillation in a defibrillator patient. The mechanism is probably stunning of the right bundle branch, causing right intraventricular conduction delay and decrease in signal amplitude reaching the endocardial sensing dipoles.
INTRODUCTION: Distinct surface ECG morphologies (ECGMs), from one episode to the next, of recurrent monomorphic ventricular tachycardia (VT) in the same patient complicate endocardial catheter mapping and the success of ablative therapy. This study investigates the incidence and mechanisms of multiple ECGMs during recurrent monomorphic VTs in a canine model of experimental myocardial infarction (MI). METHODS AND RESULTS: Computerized ECG analysis and simultaneous endocardial and epicardial activation mapping with a 64 bipolar electrode array were used to analyze the relation between site of VT origin, local activation sequence, and surface ECGM in 72 VT episodes induced in 9 of 17 dogs with experimental MI. Pairwise comparisons of all VTs induced in the same animal were done in drug-free state (47 VTs) and after intravenous procainamide (25 VTs). In drug-free state, VT pairs with similar surface ECGMs manifested endocardial breakthrough sites (BSs) within a distance < 10 mm in 46 (100%) of 46 VT pairs compared to 43 (45%) of 95 VT pairs with different surface ECGMs (P < 0.0001). Of all 89 VT pairs with endocardial BSs within < 10 mm, similar endocardial activation patterns were found in 34 (74%) of 46 pairs with similar ECGMs in contrast to 6 (14%) of 43 pairs with different ECGMs (P < 0.001). Similar comparisons of VT pairs induced after intravenous procainamide administration showed that the endocardial BSs were located within < 10 mm in 9 (75%) of 12 VT pairs with similar and in 17 (49%) of 95 with different surface ECGMs, respectively (P = NS). CONCLUSIONS: In the same heart, similar surface ECGMs of recurrent VT are highly predictive of closely spaced endocardial BSs in drug-free state, but not after procainamide administration. Nearly half of the VTs with different surface ECGMs still originate from closely spaced endocardial BSs but commonly manifest a change in the endocardial activation spread from this site. Thus, assumptions about different mechanisms and sites of VT origin based on different surface ECGMs should be made with caution.
We present a patient with sotalol-induced polymorphic ventricular tachycardia that was seen only with programmed ventricular stimulation. Electrophysiologic studies performed prior to initiation of sotalol therapy revealed inducible monomorphic ventricular tachycardia. Possible underlying electrophysiologic mechanisms are discussed.
BACKGROUND: Important sex differences in the epidemiology of sudden death and in the results of electrophysiological testing in survivors of cardiac arrest have been identified. These differences are currently poorly understood. METHODS AND RESULTS: Three hundred fifty-five consecutive survivors of out-of-hospital cardiac arrest (84 women and 271 men) referred for electrophysiologically guided therapy were analyzed retrospectively for sex differences in underlying pathology and predictors of outcome. Women were significantly less likely to have underlying coronary artery disease than men (45% versus 80%) and more likely to have other forms of heart disease or structurally normal hearts (P<.0001). The mean left ventricular ejection fraction was higher in women (0.46+/-0.18 versus 0.41+/-0.18, P<.05), and women were more likely to have no inducible arrhythmia at baseline electrophysiological testing (46% versus 27%, P=.002), although when the patients were stratified by coronary artery disease status, these sex differences were no longer present. The independent predictors of outcome differed between men and women. In men, a left ventricular ejection fraction of <0.40 was the most powerful independent predictor of total (relative risk, 2.8; 95% CI, 1.6 to 5.0; P<.0001) and cardiac (relative risk, 6.3; 95% CI, 2.9 to 13.5; P<.0001) mortality. In contrast, the presence of coronary artery disease was the only independent predictor of total (relative risk, 4.5; 95% CI, 1.5 to 13.4; P=.003) and cardiac (relative risk, 4.4; 95% CI, 1.2 to 15.6; P=.012) mortality in women. CONCLUSIONS: Females survivors of cardiac arrest are less likely to have underlying coronary artery disease. The predictors of total and cardiac mortality differ between male and female survivors. Coronary artery disease status is the most important predictor in women, and impaired left ventricular function is the most important predictor in men.
We propose that in clinical practice, whenever possible, the VT detection interval should be selected by adding >60 ms to the induced maximal VT cycle length in order to ensure a high sensitivity for the detection of future spontaneous VT episodes.
BACKGROUND AND HYPOTHESIS: Head-up tilt is widely used in evaluating patients with syncope. Data suggest that baseline tilt without isoproterenol is associated with few (< or = 10%) positive results in normals. However, there is considerable day-to-day variability in patients with syncope, resulting in low reproducibility. We hypothesized that repeating the baseline tilt would increase the total number of positive responses. METHODS: In all, 193 patients with syncope of unknown etiology prospectively underwent serial baseline tilt (Tilt-1 and Tilt-2) at 70 degrees for 25 min on two consecutive days. RESULTS: Of 193 patients, 39 (20%) had a positive Tilt-1. Of these, 19 had a positive Tilt-2, (positive concordance rate: 19/39 = 49%). Of 154 patients with a negative Tilt-1, 145 had a negative Tilt-2 (negative concordance rate: 142/151 = 94%). Only 9 of 154 patients (6%) with a negative Tilt-1 had a positive Tilt-2. Thus, the yield increased from 20% (39/193) after Tilt-1, and to 25% (48/193) after Tilt-1 plus Tilt-2, p = NS. CONCLUSIONS: (1) Reproducibility of a positive Tilt-1 is moderate. (2) Reproducibility of a negative Tilt-1 is high. (3) Repetition of tilt in patients with a negative Tilt-1 does not significantly increase the number of positive results.
The diagnostic accuracy of implantable cardioverter defibrillators may be improved by automatically adjusting gain algorithms, which in general reduce the likelihood of oversensing while maintaining the ability to detect the low amplitude signals associated with ventricular fibrillation. We present a patient with a third-generation device who developed prolonged ventricular asystole arising as a complication of the automatic gain feature. During asystole the device automatically increased sensitivity in order to prevent undersensing of ventricular fibrillation, which in this case resulted in far-field sensing of atrial activity and inhibition of ventricular pacing.
Explore the source record for details and available documents.
BACKGROUND: Implantable cardioverter/defibrillators (ICDs) may reduce sudden tachyarrhythmic death in patients with severe left ventricular dysfunction. It is uncertain whether this improves survival, particularly in patients awaiting cardiac transplantation. METHODS AND RESULTS: The effect of treatment for spontaneous ventricular arrhythmias (ICD [n = 59], antiarrhythmic drugs [n = 53], or no antiarrhythmic treatment [n = 179]) on total mortality and mode of cardiac death was analyzed in 291 consecutive patients evaluated for cardiac transplantation between January 1986 and January 1995. There were 109 deaths (37.4%) (63 [21.6%] sudden, 40 [13.7%] nonsudden, and 6 [2.1%] noncardiac) during mean follow-up of 15 months (range, 1 to 118 months). Baseline clinical variables, medical therapies for heart failure, and actuarial rates of transplantation were similar between treatment groups. Kaplan-Meier sudden death rates were lowest in the ICD group, intermediate in the no antiarrhythmic treatment group, and highest in the drug treatment group throughout follow-up (12-month sudden death rates, 9.2%, 16.0%, and 34.7%, respectively; P = .004). Total mortality and nonsudden death rates did not differ. Cox proportional-hazards model revealed that antiarrhythmic drug treatment was associated with sudden death (relative risk, 2.1; 95% CI, 1.04 to 3.39; P = .04) and ICD was associated with nonsudden death (relative risk, 2.26; 95% CI, 1.12 to 4.62; P = .02). CONCLUSIONS: Sudden death rates were lowest in patients treated with ICDs compared with drug treatment or no antiarrhythmic treatment. However, although ICDs reduced sudden death in selected high-risk patients with severe left ventricular dysfunction, the effect on long-term survival was limited, principally by high nonsudden death rates.
OBJECTIVE: The aim of this study was to describe the longitudinal course of patients who were referred for ambulatory electrocardiographic monitoring because of palpitations. METHODS: A prospective, follow-up examination was conducted of patients who had been studied 6 months previously when referred for monitoring. The inception cohort consisted of 145 consecutive patients with palpitations and 70 asymptomatic, nonpatient volunteers. At follow-up, the patients completed the same research battery as at inception, consisting of structured interviews and self-report questionnaires. These assessed cardiac symptoms, medical care use, role impairment, somatization, hypochondriacal fears and beliefs, and psychiatric disorder. RESULTS: At 6 months' follow-up, 130 patients with palpitations (89.7% of the original cohort) and 69 nonpatients (98.6%) were reinterviewed. Eighty-four percent of the patients had recurrent palpitations during the 6-month follow-up period. At follow-up, patients with palpitations scored significantly higher than the comparison group on measures of cardiac symptoms and role impairment, and had made more physician visits in the preceding 6 months. They had a higher prevalence of panic disorder and more psychopathologic symptoms, somatized more, and were more hypochondriacal. Psychiatric symptoms and the tendency to amplify bodily sensation, measured at inception, were significant but modest predictors of subsequent palpitations. There was considerable confusion and misunderstanding among patients as to the findings of their ambulatory electrocardiogram and the presence or absence of panic disorder. CONCLUSIONS: Patients with palpitations remain symptomatic and functionally impaired and have increased rates of physician visits in the 6 months following Holter monitoring. They also continue to have elevated rates of panic disorder and to evidence some confusion about the cause of their symptoms.
Postoperative electrocardiographic (ECG) changes are frequently present after insertion of implantable cardioverter-defibrillators (ICD) and may mimic perioperative myocardial infarction (MI). The purpose of this study was to assess the incidence and clinical significance of postoperative ECG changes in relation to clinical, laboratory, and implantation data. In 25 (16%) of 156 patients undergoing ICD implantation, significant ECG changes (> or = 50% reduction in R-wave amplitude in > or = 3 leads or new Q waves in > or = 2 leads) were present 1 to 3 days after the operation and persisted at hospital discharge in 12 (8%). Presence of thoracotomy, the total number of induced ventricular fibrillation episodes, and the number of defibrillation shocks required during defibrillation threshold (DFT) testing correlated with postoperative ECG changes. Other factors associated with a significant R-wave loss in the lateral precordial leads included left-sided pleural effusion, lung infiltrates or atelectasis, and large defibrillator patch electrodes over the left ventricle or the lateral chest wall. Myocardial necrosis documented by elevated cardiac enzymes occurred in 6 (5%) of 151 patients without significant ECG changes and in 3 (12%) with (p value not significant). However, postoperative ECG changes associated with elevated enzymes were indistinguishable from changes unrelated to necrosis. Therefore the sensitivity and specificity of the surface ECG for detection of MI after ICD placement is poor. Multiple factors such as thoracotomy, myocardial injury from DFT testing, electric insulation, or shielding of the heart may contribute to the development of electrocardiographic pseudo-infarct patterns.
Among 177 patients in whom a nonthoracotomy approach was initially used to implant a cardioverter-defibrillator system, 11 (6%) patients also received a separately implanted permanent pacemaker. The main problem encountered in these patients were previously implanted unipolar pacemakers (n = 3) and ventricular pacing leads positioned at the right ventricular apex, the latter interfering with optimal placement of the tripolar implantable cardioverter-defibrillator (ICD) lead (n = 9). The approaches used to solve these problems were individualized and included placement of the ICD sensing lead at the right ventricular outflow tract (n = 3), initial placement (n = 1) or subsequent repositioning (n = 2) of the right ventricular pacing lead at the outflow tract, upgrade from unipolar to bipolar systems (n = 2), reprogramming from the DDD to AAI mode (n = 2), inactivation of the pacemaker (n = 1), and simultaneous placement of a single-chamber atrial pacemaker with the ICD lead (n = 2). These revisions fulfilled the pacing needs in each patient and prevented unfavorable sensing interaction between the two systems.
Explore the source record for details and available documents.
OBJECTIVES: We studied the duration and prognostic significance of atrial arrhythmias in the denervated transplanted heart, specifically the occurrence of atrial fibrillation in the absence of vagal modulation. BACKGROUND: Substantial animal data indicate that vagally induced dispersion of atrial refractoriness plays a central role in the induction and maintenance of atrial fibrillation. METHODS: We studied the occurrence of atrial arrhythmias in the denervated hearts of 88 consecutive orthotopic transplantations in 85 patients by means of continuous telemetry and all available electrocardiographic tracings. RESULTS: Fifty percent of recipients (44 of 88) developed at least one atrial arrhythmia. Atrial fibrillation occurred 23 times (21 recipients), atrial flutter 39 times (26 recipients), ectopic atrial tachycardia 3 times (3 recipients) and supraventricular tachycardia 18 times (11 recipients). The number of atrial fibrillation and atrial flutter episodes did not differ (23 vs. 39, p = 0.072), but the mean duration of atrial flutter was longer than that of atrial fibrillation (37.0 +/- 10 vs. 6.6 +/- 3.6 h, p = 0.014). Atrial fibrillation was associated with an increased risk of subsequent death (10 of 21 recipients with vs. 15 of 67 without atrial fibrillation, risk ratio 3.15 +/- 0.18, p = 0.005 by Cox proportional hazards model). All 5 recipients who developed "late" atrial fibrillation (> 2 weeks after transplantation) died versus 5 of 16 who developed atrial fibrillation within the first 2 weeks (p = 0.007). Causes of death included rejection (three recipients), allograft failure (two recipients), infection (three recipients) and multiorgan failure (two recipients). Atrial fibrillation was not associated with age, gender, ischemic time, reason for transplantation, echocardiographic variables, invasive hemodynamic variables or biopsy grade. Mean time from atrial arrhythmia to echocardiography was 2.7 +/- 3.3 days; that to biopsy was 4.8 +/- 6.3 days. Atrial flutter was not associated with subsequent death. Only 7 (15.9%) of 44 recipients demonstrated moderate or severe allograft rejection at the time of the arrhythmia. CONCLUSIONS: Atrial arrhythmias occur frequently in the denervated transplanted heart, often in the absence of significant rejection. Late atrial fibrillation may be associated with an increased all-cause mortality.
Appropriately timed noncompetitive ventricular pacing potentially may initiate ventricular tachycardia in patients prone to these arrhythmias. The combination of bradycardia pacing and stored electrograms in a currently available cardioverter defibrillator provides an opportunity to evaluate the occurrence of such pacing induced ventricular tachycardia. During a surveillance period of 18.7 +/- 11.4 months, stored electrograms documented 302 episodes of ventricular tachycardia in 77 patients. Five patients (6.5%) demonstrated 25 episodes (1-16 per patient) of ventricular tachycardia that were immediately preceded by an appropriately paced ventricular beat (8.3% of all episodes of ventricular tachycardia). All five patients had prior myocardial infarctions and a history of monomorphic ventricular tachycardia occurring both spontaneously and in response to programmed electrical stimulation. Antitachycardia pacing terminated pacing induced ventricular tachycardia in 22 episodes; in one episode antitachycardia pacing accelerated ventricular tachycardia. In two cases shock therapy was aborted for nonsustained ventricular tachycardia. We conclude that, in selected nonsustained ventricular tachycardia. We conclude that, in selected postinfarction patients with recurrent sustained monomorphic ventricular tachycardia treated with implantable cardioverter defibrillators, appropriately timed ventricular pacing may induce ventricular tachycardia.
UNLABELLED: Subclavian crush syndrome, described with pacemaker leads implanted via subclavian puncture, may occur when conductor fractures and insulation breaches develop by compression of a lead between the first rib and clavicle. We reviewed our experience in 164 patients who underwent intended implantation of transvenous defibrillator systems to determine the clinical relevance of subclavian crush syndrome in defibrillator patients. Venous access was obtained via subclavian puncture in 114 patients (70%) and via cephalic cut-down in 50 patients (30%). Nonthoracotomy lead systems, with or without subcutaneous patch, were successfully implanted in 131 of 164 patients (79.9%). Thoracotomy was required in 32 patients (19.5%) and subxiphoid patch in 1 patient (0.6%). Over a mean of 12.9 months (range 1-62 months), 3 patients (1.8%) required revision of the rate sensing lead/coil or superior vena cava coil after development of lead compression fractures in the region of the clavicle and first rib. In all 3 patients the leads had been implanted via subclavian puncture (2.6% of patients in whom the subclavian technique was utilized). Two patients presented with spurious shocks. One patient was asymptomatic. CONCLUSIONS: When venous access is obtained via subclavian puncture, subclavian crush syndrome may develop in patients with transvenous defibrillator systems. Patients may be asymptomatic and lead fractures may go unrecognized. When implanting transvenous defibrillator systems, strong consideration should be given to obtaining venous access primarily via the cephalic cut-down technique.
To date, no long-term clinical data have been published in patients undergoing a nonthoracotomy approach to cardioverter-defibrillator system implantation. In the present report, 189 consecutive patients prospectively underwent a standardized approach to cardioverter-defibrillator system implantation in which the nonthoracotomy configurations were tested first. If satisfactory defibrillation thresholds were not obtained, thoracotomy was performed during the same intraoperative session. A nonthoracotomy system was successfully implanted in 149 of 189 patients (79%), with a higher success rate (90%) observed in patients who had more recent implantations. The overall rate of complications associated with these systems was low (11%). Over a mean follow-up of 12.5 +/- 9.3 months, 17 patients (9%) died. Three-year total, cardiac, and sudden death-free actuarial survival for all patients was 83 +/- 11%, 88 +/- 7%, and 94 +/- 2%, respectively. Three-year sudden death-free actuarial survival was higher in the nonthoracotomy than in the thoracotomy patients (97 +/- 2% vs 87 +/- 6%, p = 0.047), although total survival was similar (77 +/- 11% vs 83 +/- 7%, p = 0.77). These data suggest that a majority of patients (> 80%) requiring a cardioverter-defibrillator system can undergo implantation using a nonthoracotomy approach. Patients receiving nonthoracotomy systems have 3-year outcomes comparable to those implanted via thoracotomy. If these results are maintained, a nonthoracotomy approach will supplant thoracotomy-implanted systems as the preferred method because of the simpler implant procedure and lower overall cost involved.