PubMed Health⌕ Search

Biomedical subjects

J Naumann

Publications and source records attributed to J Naumann.

13 recordsLinked to original sources

Measurement of helicity-dependent photoabsorption cross sections on the neutron from 815 to 1825 MeV.

Helicity-dependent total photoabsorption cross sections on the deuteron have been measured for the first time at ELSA (Bonn) in the photon energy range from 815 to 1825 MeV. Circularly polarized tagged photons impinging on a longitudinally polarized LiD target have been used together with a highly efficient 4pi detector system. The data around 1 GeV are not compatible with predictions from existing multipole analyses. From the measured energy range an experimental contribution to the GDH integral on the neutron of [33.9 +/- 5.5(stat) +/- 4.5(syst)] microb is extracted.

Journal Article↗

[Amalgam risk assessment with coverage of references up to 2005].

Amalgam, which has been in use in dentistry for 150 years, consists of 50 % elemental mercury and a mixture of silver, tin, copper and zinc. Minute amounts of mercury vapour are released continuously from amalgam. Amalgam contributes substantially to human mercury load. Mercury accumulates in some organs, particularly in the brain, where it can bind to protein more tightly than other heavy metals (e. g. lead, cadmium). Therefore, the elimination half time is assumed to be up to 1 - 18 years in the brain and bones. Mercury is assumed to be one of the most toxic non-radioactive elements. There are pointers to show that mercury vapour is more neurotoxic than methyl-mercury in fish. Review of recent literature suggests that mercury from dental amalgam may lead to nephrotoxicity, neurobehavioural changes, autoimmunity, oxidative stress, autism, skin and mucosa alterations or non-specific symptoms and complaints. The development of Alzheimer's disease or multiple sclerosis has also been linked to low-dose mercury exposure. There may be individual genetical or acquired susceptibilities for negative effects from dental amalgam. Mercury levels in the blood, urine or other biomarkers do not reflect the mercury load in critical organs. Some studies regarding dental amalgam reveal substantial methodical flaws. Removal of dental amalgam leads to permanent improvement of various chronic complaints in a relevant number of patients in various trials. Summing up, available data suggests that dental amalgam is an unsuitable material for medical, occupational and ecological reasons.

Adult↗

Experimental check of the Gerasimov-Drell-Hearn sum rule for 1H.

For the first time we checked the fundamental Gerasimov-Drell-Hearn (GDH) sum rule for the proton experimentally in the photon energy range from 0.2-2.9 GeV with the tagged photon facilities at MAMI (Mainz) and ELSA (Bonn). New data of the doubly polarized total cross section difference are presented in the energy range from 1.6 to 2.9 GeV. The contribution to the GDH integral from 0.2-2.9 GeV yields [254+/-5(stat)+/-12(syst)] microb with negative contributions in the Regge regime at photon energies above 2.1 GeV. This trend supports the validity of the GDH sum rule.

Journal Article↗

Amalgam studies: disregarding basic principles of mercury toxicity.

Dental amalgam, which has been used for over 150 years in dental practice, consists of about 50% metallic mercury. Studies on animal and humans show that mercury is continuously released from dental amalgam and absorbed by several body tissues. It is widely accepted that the main source of mercury vapor is dental amalgam and it contributes substantially to mercury load in human body tissues. There is still a controversy about the consequences of this additional mercury exposure from amalgam to human health. Many studies were performed to evaluate possible adverse effects. In this comment, these studies were analyzed with regard to their methodical quality by considering the newest findings on mercury toxicity and metabolism. In sum, a number of studies are methodically flawed drawing inaccurate conclusions as to the safety of dental amalgam.

Dental Amalgam↗

First Measurement of the Gerasimov-Drell-Hearn Sum Rule for 1H from 0.7 to 1.8 GeV at ELSA.

To verify the fundamental Gerasimov-Drell-Hearn (GDH) sum rule for the first time experimentally, we measured the helicity dependent total photoabsorption cross section with circularly polarized real photons and longitudinally polarized nucleons in the photon energy range 0.68-1.82 GeV with the tagged photon facility at ELSA. The experiment was carried out with a 4pi detection system, a circularly polarized tagged photon beam, and a frozen spin polarized proton target. The contribution to the GDH sum rule in this photon energy range is [49.9+/-2.4(stat)+/-2.2(syst)] microb.

Journal Article↗

SAP and partners: IS-H and IS-H* MED.

OBJECTIVES: The Styrian Hospital Organization with 21 hospitals including the Graz University Hospital, and the Heidelberg University Hospital implemented a new HIS based on SAP/R3, ISH, ISH* MED with the objective to have an integrated system to support patient administration and management, patient care, clinical documentation, research etc. METHODS: Heidelberg University Hospital chose a step by step method for the introduction of the system, beginning with patient administration (ISH) and proceeding with clinical functions (ISH* MED). In Styria, the full functionality was implemented--as part of the selection process--in one peripheral hospital and in the Ear, Nose and Throat (ENT) Department of the Graz University Hospital, including special documents to support the processes in the highly specialized ENTunits. RESULTS AND CONCLUSIONS: The standard modules are performant, stable and basically well accepted. Particularly in Graz, it has been shown that the requirements of highly specialized departments for work flow management, documentation and integration of subsystems and data from different sources can be fulfilled by special documents and programs--although at the expense of additional workload particularly in the initial phases of such a project.

Austria↗

Helicity amplitudes A1/2 and A3/2 for the D13(1520) resonance obtained from the gamma-->p-->-->ppi(0) Reaction.

The helicity dependence of the gamma-->p-->-->ppi(0) reaction has been measured for the first time in the photon-energy range from 550 to 790 MeV. The experiment, performed at the Mainz microtron MAMI, used a 4pi-detector system, a circularly polarized, tagged photon beam, and a longitudinally polarized frozen-spin target. These data are predominantly sensitive to the D13(1520) resonance and are used to determine its helicity amplitudes.

Journal Article↗

Helicity dependence of gammap --> Npi below 450 MeV and contribution to the Gerasimov-Drell-Hearn sum rule.

The helicity dependence of the single pion photoproduction on the proton has been measured in the energy range from 200 to 450 MeV for the first time. The experiment, performed at the Mainz microtron MAMI, used a 4pi-detector system, a circularly polarized, tagged photon beam, and a frozen-spin target. The data obtained provide new information for multipole analyses of pion photoproduction and determine the main contributions to the Gerasimov-Drell-Hearn sum rule and the forward spin polarizability gamma(0).

Journal Article↗

Response times in attitudinal items as indicators of the continuous accessibility of knowledge related to attitudes.

In the paradigm of social cognition, the measurement of response latencies is important not only for priming procedures directed at the cognitive representation, but also for the assessment of strength-related properties of attitudes. The present paper explored the possibility of using response times as indicators of the continuous accessibility of attitude-relevant knowledge. For two different sets of attitudinal items concerning social welfare (idiographic and nomothetic selection) response times were obtained from a sample of 20 university students. In addition to different reliability coefficients for aggregated response times, information about individual subjects' consistencies and stabilities was obtained. Further, evidence for the validity of response times as indicators of the continuous accessibility of attitude-related knowledge is reported. The aggregated response times had significant correlations with self-report data and interview-related variables (such as number of propositions mentioned) which were obtained by a content analysis of semistructured interviews.

Adult↗

Comparison of sensitivity towards photodynamic therapy of cutaneous resident and infiltrating cell types in vitro.

BACKGROUND AND OBJECTIVE: Photodynamic therapy (PDT) combines photosensitizers absorbing light in the visible spectral region and irradiation with light of corresponding wavelengths. We analysed the sensitivity of cell lines established from resident cutaneous cells and from transformed lymphocytes towards PDT. STUDY DESIGN/MATERIALS AND METHODS: PDT was performed employing either 630 or 662 nm light or polychromatic red light (600-700 nm) and photosensitizers Photosan-3, delta-aminolevulinic acid, or methylene blue. Proliferation measured by 3H-TdR uptake was determined in human immortalized keratinocytes (HaCaT) and mouse fibroblasts (NIH/3T3) in comparison to human transformed T-(HuT78) and B-lymphocytes (RA1). Additionally, uptake of the photosensitizers was estimated employing video-intensified fluorescence-microscopy (VIFM). RESULTS: Depending on the photosensitizer tested HaCaT and NIH/3T3 exhibited an ED50 up to 10-fold as high as the lymphocytic lines. Polychromatic red light was at least as effective at inducing photodynamic reactions as 630 or 662 nm light. VIFM revealed a positive correlation between sensitivity of a given cell type towards PDT and uptake of the photosensitizers. The differential uptake observed in vitro was confirmed in vivo: A photosensitizer applied topically on a lesion of a patient with mycosis fungoides was found to accumulate preferentially in the lymphocytic infiltrate. CONCLUSION: Selective topical polychromatic PDT seems to be a feasible goal for the treatment of cutaneous lymphomas.

Aminolevulinic Acid↗

[Calcium oxalate activity products and discriminant analysis of urinary parameters as basis for a calcium oxalate screening program (author's transl)].

The values of 7 urinary parameters in divided urine collections were measured in 20 patients with calcium oxalate stones and ten normal persons. On this basis the thermodynamic stone formation risk was calculated for the different urine collections. Stone formation risk in the 0-6 a.m. urine fractions appeared to be the most important. The risk of stone formation is significantly increased in the time from midnight to 6 a.m. To detect the risk situation the determination of oxalic acid, calcium, potassium and inorganic sulfate in night urine is adequate.

Calcium↗