J Neuerburg

Publications and source records attributed to J Neuerburg.

At least 19 recordsLinked to original sources

Value of intravenous cholangiography prior to laparoscopic cholecystectomy.

We performed a retrospective study on 163 patients for evaluation of the benefit of intravenous cholangiography prior to laparoscopic cholecystectomy. Radiographic evaluation of the various areas of the biliary system was classified regarding resolution of anatomic structures: well detailed (excellent), impaired image but reliable interpretation possible (good), insufficient contrast with limited assessment (poor), no reliable judgment possible (insufficient). The common bile duct could be described as "good" in 96.3%, whereas the cystic duct could be described as "good" in only 54.6%. Concrements of the gallbladder were recognized in 72.4%, and common bile duct stones were diagnosed in only two of three patients. A distal junction of the cystic duct was found in nine cases, but there was no influence on the following operative procedure. Only one of two patients with a short cystic duct was identified. We found no improvement after routine use of intravenous cholangiography concerning the evidence of common bile duct stones or the avoidance of lesions of the common bile duct. Hence routine use of intravenous cholangiography prior to laparoscopic cholecystectomy is not justified.

Bile Ducts, Intrahepatic

[Clinical value of FDG PET for therapy monitoring of malignant lymphoma--results of a retrospective study in 72 patients].

AIM: Of the present retrospective study was to validate the clinical value of FDG-PET for therapy control of malignant lymphoma. METHOD: 72 patients (41 non-Hodgkin lymphomas, 29 Hodgkin's disease, 2 unclassified) received static FDG-PET scans of initially involved regions (n = 53) or of the entire neck and trunk (n = 19) after therapy. CT imaging (n = 70) and serum LDH measurement (n = 64) were also performed. Results were validated either by biopsy (n = 7) or by clinical follow-up (n = 65). The predictive value of PET was analysed in relation to different prognostic factors (stage, recurrence status, number of prior therapy regimen). RESULTS: PET obtained a sensitivity of 88%, a specificity of 83% and an overall accuracy of 85% for detection of residual disease. The values for CT were 84%, 31% resp. 54%, and for serum LDH 50%, 92% and 73%. The predictive value of PET was related to the prevalence of residual disease. PET predicted complete remission in more than 90% of patients with moderate risk (stage I-III, no relapse, no more than two different therapy regimens). In high risk patients, however, the negative predictive value of PET was 50-67%. CONCLUSION: FDG-PET is more accurate than CT imaging and LDH measurement for therapy monitoring of malignant lymphoma. Therapy success can be reliably predicted in patients with moderate risk.

Adolescent

[Interventional MR tomography: equipment concepts].

Interventional MRI is one of the most recent developments of clinical MR imaging. Because of the development of open MR systems and very compact high-field systems, a number of interventional procedures are already possible today under MR control and will be tested in experimental and clinical investigations. The currently commercially available systems differ with respect to their static magnetic field strength, their gradient systems and patient access. In addition, there are differences concerning their space requirements and costs. All systems have components facilitating interventional procedures. In this article we discuss the advantages and shortcomings of these commercially available systems and look at future developments in interventional MR equipment.

Equipment Design

[A new MR-(and CT-) compatible bone biopsy system: first clinical results].

PURPOSE: To describe the development and clinical evaluation of a new, hand-powered or alternatively motor-driven, MRI and CT compatible percutaneous bone biopsy system. MATERIALS AND METHODS: A new coaxial drill system (Cook Europe A/S) was designed for percutaneous, MR-guided bone biopsies and powered either by hand or an optional motor (10-250 rotations/minute using 6 bar [88.2 PSI] compressed air). The system has been used in 23 patients. Fourteen procedures were performed in a 1.5 T MR scanner (Philips-Gyroscan ACS-NT) which has an attached C-arm (Philips-BV 212-Angio) in case fluoroscopy is required, and 9 procedures in a CT scanner (Siemens-Somatom Plus). RESULTS: Driven by hand or by the pneumatic motor unit, the system achieved safe and accurate MR-guided access to all of the lesions and was even able to penetrate osteosclerotic lesions. MR- or CT-guided percutaneous biopsy yielded a correct diagnosis in all but 5 cases. No procedural complications occurred. CONCLUSION: MR-guided percutaneous bone biopsy performed with the new coaxial drill system was found to be safe and reliable, and suitable for obtaining histological specimens from skeletal lesions even when covered with thick cortical or sclerotic bone.

Biopsy

Thrombolysis of mural thrombus by ultrasound: an experimental in vitro study.

RATIONALE AND OBJECTIVES: The authors perform an in vitro evaluation of the thrombus fragmentation to determine the efficacy and degree of downstream clot fragment embolization that occurs during transcatheter ultrasound treatment of fibrin-rich mural thrombus in a peripheral venous flow model with variable diameter tubing. METHODS: The authors used a 22.5-kHz prototype intravascular ultrasound device with a flexible 0.8-mm (.032-inch) titanium wire probe encased in a 7-French teflon guide catheter, at the tip of which is a 2-mm ball. In 50 silicone tube segments (inner diameter 3, 5, 7, 9, and 11 mm; n = 10 each), firmly adherent mural thrombus was produced using bovine blood in a modification of the Chandler's loop technique. Ultrasound energy (30-36 watts/cm), maximal longitudinal catheter tip amplitude 70 m) was applied to the thrombus while a continuous flow of water was maintained in the closed loop system. Clot fragment emboli were trapped in "downstream" polyethylene filters. RESULTS: The mean rate of thrombus removal ranged from 99% +/- 0.3% in the 3-mm segments to 76% +/- 6% in the 11-mm segments. The average weight of the fragments that embolized "downstream" and were trapped in the filters, expressed as a percentage of the initial clot weight, was 11% in the 3-mm segment, 14% in the 5-mm segment, 30% in the 7-mm segment, 29% in the 9-mm segment, and 28% in the 11-mm segments. The majority of the embolized fragments appear to be larger than 1 mm. CONCLUSIONS: In this in vitro venous flow model a lack of catheter steerability was the major obstacle to complete thrombus fragmentation in vessel calibers larger than two times the tip diameter. The rate of embolism and the amount of remaining thrombus that could not be removed from the vessel were higher in the larger vessels.

Animals

Declotting of embolized temporary vena cava filter by ultrasound and the Angiojet: comparative experimental in vitro studies.

RATIONALE AND OBJECTIVES: The authors perform an in vitro evaluation of the thrombolytic efficacy and the amount of "downstream" embolization induced by two new mechanical thrombectomy devices when applied to clots trapped in a temporary vena cava filter. METHODS: The first device used was a 22.5-kHz prototype intravascular ultrasound device with a flexible 0.8-mm (.032-inch) titanium 2-mm ball-tipped wire probe ensheathed in a 7-French teflon guide catheter. The device was inserted through a 10-French steering catheter. Under fluoroscopic control, ultrasound energy (26 +/- 4 watts/cm2, maximal longitudinal catheter tip amplitude 54 microm) was applied to 10 Ultravist-filled porcine thrombi (mean, 3500 mg). The second device, the Angiojet catheter, was applied to five Ultravist-filled porcine thrombi (mean, 3640 mg). The thrombi were treated while trapped in a temporary Günther vena cava filter (Cook Europe, Bjaverskov, Denmark) mounted in a vena cava flow model. The resultant "downstream" emboli were trapped in two tandem filters of decreasing pore size and weighed. RESULTS: Mean thrombus dissolution rate was 53% +/- 22% standard deviation (SD) for the ultrasound device (n = 10) and 63 % +/- 8% SD for the Angiojet (n = 5) (difference statistically significant at P = 0.03). For the ultrasound device, the mean embolic particle weight caught by the filters with mesh widths of 1 mm and 0.1 mm was 42% +/- 14% SD and 4% +/- 2% SD, respectively, of the initial thrombus weight. For the Angiojet, the respective numbers were 35% +/- 16% SD and 3% +/- 1% SD. Mean treatment time was 216 +/- 45 seconds SD for the ultrasound device and 153 +/- 21 seconds SD for the Angiojet. CONCLUSIONS: The thrombolytic efficacy of the Angiojet was significantly greater and the treatment time was significantly shorter than that of the ultrasound device. Both systems had a high embolization rate.

Animals

Positron emission tomography with 18F-FDG to detect residual disease after therapy for malignant lymphoma.

We retrospectively evaluated the use of 18F-FDG PET for assessment of residual disease in 27 patients after therapy for malignant lymphoma. The images were evaluated qualitatively and quantitatively using standardized uptake values (SUV). All findings were validated either by biopsy or by clinical follow-up and compared with corresponding CT findings. The impact of blood glucose concentration, body weight, body surface area, lesion diameter and the time between injection and imaging on the SUVs were analysed. All 15 patients with biopsy-proven residual disease or relapse during follow-up and 11 of 12 patients who remained relapse-free were correctly identified by qualitative interpretation of the PET images. A case of pneumonitis after radiotherapy/chemotherapy accounted for the only false-positive finding. Compared with CT imaging, PET had a significantly higher specificity (P < 0.01), accuracy (P < 0.05) and positive predictive value (P < 0.05). The mean and maximum SUV of the tumour lesions were positively correlated to lesion diameter (P < 0.01) and imaging time post-injection (P < 0.01). Standardized uptake values corrected for the partial volume effect and normalized to a standardized imaging time (SUVBPT) were significantly higher (P < 0.05) in high-grade than in low-grade non-Hodgkin's lymphoma. In conclusion, 18F-FDG PET may help in the identification of patients who need additional treatment after the completion of conventional therapy. Qualitative image interpretation appears sufficient for this purpose.

Adolescent

Catheter visualization using locally induced, actively controlled field inhomogeneities.

A new technique for visualization of interventional devices using MR is presented. A prototype catheter was equipped with a thin copper wire loop, leading from the proximal end to the tip and back. A small current (10-150 mA) through these two parts of a wire induces a local magnetic field along the catheter. Introduction of this catheter into the main magnetic field of the MR imager locally disturbs the homogeneity of the magnetic field. Image locations within the locally induced fields appear dark due to signal loss, and the extent of this effect can be varied during the procedure by simply adjusting the current. Different dedicated wire configurations allow visualization of the catheter in its whole length or in parts, i.e., with markers for balloons. Fast gradient echo sequences that provide a bright signal from inflowing blood are used for rapid imaging.

Animals

[Endosonography control of percutaneous paracoccygeal drainage of deep pelvic abscesses after rectum resection].

Pelvic abscesses are severe complications after rectal surgery. In recent years, surgical drainage has been edged out by percutaneous drainage techniques. We report our experience with the drainage of postoperative pelvic abscesses via the paracoccygeal route controlled by endosonography. In eight patients the diagnosis of a retrorectal pelvic abscess was established by endosonography and confirmed by endosonographically controlled exploratory puncture. Drainage of the abscesses was performed via the paracoccygeal access route by trocar or Seldinger technique under permanent visual control by endoluminal sonography. Irrigation of the abscess cavity was than performed daily. In all cases drainage was successful without complications. Duration of drainage was 9-14 days with a mean of 10.8 days. In one patient there was a recurrence of the abscess because of early removal of the drainage catheter. Because of its overall availability and its good results, paracoccygeal percutaneous endosonographically controlled drainage seems to be a suitable uncomplicated method for drainage of postoperative pelvic abscesses.

Abdominal Abscess

[Catheter visualization in MR-tomography: initial experimental results with field-inhomogeneity catheters].

PURPOSE: To assess the feasibility of a new developed field inhomogeneity catheter for interventional MR imaging in vivo. MATERIALS AND METHODS: Three different prototypes of a field inhomogeneity catheter were investigated in 6 pigs. The catheters were introduced in Seldinger technique via the femoral vessels over a guide wire on an interventional MR system (Philips Gyroscan NT combined with a C-arm fluoroscopy unit [Philips BV 212]). Catheters were placed in veins and arteries. The catheter position was controlled by a fast gradient echo sequence (Turbo Field Echo [TEE]). RESULTS: Catheters were introduced over a guide wire without complications in all cases. Using the field inhomogeneity concept, catheters were easily visualised in the inferior vena cava and the aorta by the fast gradient echo technique on MR in all cases. Although aortic branches were successfully cannulated, the catheters were not displayed by the TFE technique due to the complex and tortuous anatomy. All animals survived the experiments without complications. CONCLUSION: MR guided visualization of a field inhomogeneity catheter is a simple concept which can be realised on each MR scanner and may allow intravascular MR guided interventions in future.

Animals

[Flow direction-sensitive spin-echo MR angiography].

New blood pool contrast agents yield a significant shortening of T1 of blood. Consequently, the usual techniques of time-of-flight and phase-contrast angiographies cannot produce angiograms sensitive to one flow direction, even if saturation slabs are applied. It was our aim to test the hypothesis of displaying arterial and venous flow selectively with a specially designed spin echo sequence even after administration of contrast agents. Parallel slice selective 90-degree and 180-degree pulses were applied. The distance between slices could be varied. It was attempted to obtain MR angiographies that were flow sensitive for one direction only. We performed flow phantom studies without the use of contrast media and first in vivo experiments in pigs after administration of iron oxide particles. With our modified spin echo sequence unidirectional flow can be displayed, whereas stationary tissue is totally suppressed. There are no special demands for the hardware and no additional postprocessing needs to be performed. The locally off-centred 90-degree and 180-degree pulses are responsible for this. Exclusively, protons excited by the 90-degree pulse and flowing into the slice of the 180-degree pulse will be refocused and only such protons will give rise to signal in the images.

Animals

[T1-weighted excretory MR urography using GD-DTPA after low-dose diuretic administration].

PURPOSE: Assessment of the morphology of the urinary tract by gadolinium (Gd)-enhanced T1-weighted MR-urography (MRU) and precontrast diuretic injection. METHODS: MRU was performed in 5 patients using Gd-DTPA-enhanced coronal T1-weighted 3D-gradient-echo sequences with different spatial resolution. Prior to contrast injection, 10 mg of furosemide were administered intravenously. RESULTS: Secondary to the precontrast furosemide injection, the increase of the renal excretion rate allows complete visualisation of the entire collecting system within 10 minutes following Gd injection. Maximum intensity projections provide a three-dimensional overview of the ureters separate from the bladder. To achieve detailed anatomic imaging of the calices, both optimal distension and high resolution sequences are prerequisites which cannot be realized by means of survey urograms only. CONCLUSIONS: Contrast-enhanced excretory MRU performed after injection of a diuretic offers a rapid approach to visualising the morphology of the nondilated urinary tract. Imaging of caliceal details must be done with high-resolution 3D-gradient-echo sequences.

Adult

[Cava filter placement under MRI control. Experimental in vitro and in vivo studies].

PURPOSE: An instrument has been developed for the introduction of caval filters which can be used with MRI; it has been investigated in in vitro and in in vivo experiments. MATERIAL AND METHOD: The ferromagnetic components of a commercially available instrument for the femoral introduction of the MR-eye Tulip IVC filter were changed for similar, non-ferromagnetic parts and the lock and dilator marked with dysprosium oxide rings. The instrument was used in a flow phantom and in animal experiments (two domestic pigs) in order to insert filters under MRI control on a 1.5 T Philips Gyroscan with integrated mobile digital subtraction angiography. RESULTS: Both in vitro and in vivo, the introducer, catheter and caval filter could be identified by MRI and positioned under MRI control. The position of the filter as indicated by MRI corresponded with radiological and macroscopic findings in all cases (5 phantoms, 2 pigs). CONCLUSION: The early experimental results indicate that percutaneous introduction of caval filters with placement under MRI control is possible.

Animals

Interventional magnetic resonance. Initial clinical experience with a 1.5-tesla magnetic resonance system combined with c-arm fluoroscopy.

RATIONALE AND OBJECTIVES: The authors evaluate the feasibility of performing magnetic resonance (MR) procedures on a 1.5-tesla (T) system combined with conventional c-arm fluoroscopy. METHODS: A 1.5-T MR imaging system was combined with a conventional c-arm fluoroscopy unit in one room. The two systems were connected via a floating table top. Twenty-six interventional procedures (biopsies, MR-portography, percutaneous alcohol injection, laser ablation, fluid aspiration, and breast marking) were performed in 22 patients under MR, fluoroscopic control, or both. For MR guidance, fast gradient echo sequences were used, initiated from a panel at the front of the magnet. Images were displayed on an liquid crystal display screen positioned on the magnet. RESULTS: All MR-guided procedures were performed successfully without complications. The addition of c-arm fluoroscopy was useful for bone interventions and MR-portography. All diagnostic biopsies yielded sufficient amounts of tissue for histologic diagnosis. In breast lesions, the target identified on dynamic MR imaging was marked correctly in each case. In interstitial laser thermotherapy the laser effect could be visualized, and in percutaneous ethanol injection the distribution of the alcohol could be seen. Both imaging systems worked without image distortions and high-quality MR images were obtained. CONCLUSIONS: The combination of a 1.5-T MR imager with a c-arm fluoroscopy system seems to be a promising technical solution for performing interventional MR procedures.

Adult

Perigraft inflammation due to Dacron-covered stent-grafts in sheep iliac arteries: correlation of MR imaging and histopathologic findings.

PURPOSE: To evaluate with magnetic resonance (MR) imaging the inflammatory perigraft response after implantation of Dacron-covered and noncovered arterial endovascular prostheses in sheep. MATERIALS AND METHODS: Four prosthesis types--two Dacron-covered nitinol stent-grafts (plain and heparin-coated) and two noncovered nitinol stents (Memotherm and Cragg)--were each inserted into the external iliac arteries of eight sheep. MR imaging before and after gadolinium enhancement was performed 5-8 days and 1 month after implantation (before the animals were killed). Macroscopic and microscopic examinations of the vessels were performed, and findings were correlated with those on MR images. RESULTS: Severe inflammatory perigraft responses to the heparin-coated Dacron-covered stent-grafts were found; MR images demonstrated contrast enhancement and edema. Macroscopic examination showed marked vascular wall thickening and adhesions around the Dacron fabric; microscopic examination showed a pronounced inflammatory foreign-body response. There was a moderate inflammatory response to the plain Dacron-covered stent-grafts and almost no response to noncovered stents. CONCLUSION: In sheep, MR imaging findings of perigraft soft-tissue edema and contrast enhancement correlated well with histopathologic findings of severe perigraft inflammation due to heparin-coated Dacron-covered stent-grafts.

Alloys

[Comparison of findings with 18-FDG PET and CT in pretherapeutic staging of malignant lymphoma].

AIM: Comparison of diagnostic efficiency of FDG-PET and CT regarding localisation, histology, size and FDG-uptake of a lesion. METHODS: CT- and FDG-PET studies of 27 patients with histologically confirmed malignant lymphoma as primary disease or relapse were evaluated retrospectively. In CT lesions with a diameter (DCT) > 15 mm were regarded as positive. Focal accumulations of FDG, not explained by physiological metabolism, found by visual interpretation in iterative reconstructed PET-scans, were quantified for diameter (DPET) and corrected standardized uptake value (SUV), corrected for partial-volume-effect. Lesions were classified depending on histology and lesion quality (lymph nodes, bulks, extranodal lesions). RESULTS: CT detected 78 lesions in 26 patients, all confirmed by FDG-PET. PET localized 18 additional lesions (+23%); in high grade NHL +25%. Both methods were equally efficient in cervical lymph nodes and lung lesions, in all other regions of lymphatic nodules and in case of liver and spleen lesions PET localized more lesions. SUV was significantly higher in high-grade NHL (19.0) than in low-grade NHL and Hodgkin's disease (10.6 resp. 11.1). DCT and DPET correlated significantly (r = 0.75). CONCLUSION: Diagnostic efficiency of FDG-PET is equivalent or superior to CT in staging of malignant lymphoma before therapy. Qualitative interpretation seems sufficient for staging, quantitative analysis may add information about malignancy grade in NHL.

Fluorodeoxyglucose F18

[Preoperative diagnosis of laparoscopic cholecystectomy. Is there an indication for routine intravenous cholangiography?].

In a retrospective study including 163 patients we investigated the necessity of i.v. cholangiography in preoperative routine diagnostic workup prior to laparoscopic cholecystectomy. We evaluated the evidence of i.v. cholangiography concerning the anatomy of the biliary system, the evidence of common bile duct or cystic duct stones and the influence on the further therapeutic procedure. While the common bile duct could be demonstrated in 96.3%, the cystic duct could be visualized in only 54.6%. One out of two patients with a short cystic duct was identified. Stones in the gallbladder were recognized in 72.4% of cases, while only two out of three patients with common bile duct stones were diagnosed. In nine cases a deep junction of the cystic duct was found, but there was no influence on further operative procedure. Thus we found no improvement after routine use of i.v. cholangiography concerning the evidence of common bile duct stones or avoidance of intraoperative lesions of the common bile duct. The routine use of i.v. cholangiography prior to laparoscopic cholecystectomy is therefore not justified.

Adolescent

Dynamic Gd-enhanced MR imaging of hepatic hemangioma: is high temporal resolution requisite for characterization?

We assessed the value of high temporal resolution in the dynamic characterization of hepatic hemangioma with use of magnetization-prepared gradient-echo (MP-GRE) imaging. Single-level inversion recovery incremental flip angle MP-GRE images were obtained in 26 patients with 34 hemangiomas before and at a repetition rate of 30 images/min after injection of Gd-DTPA without breath-holding. Enhancement patterns and temporal changes thereof were analyzed. Hemangiomas were categorized as small ( < 2.0 cm), medium (2.0-5.0 cm), and large ( > 5 cm) lesions. Classic early peripheral nodular enhancement (PNE) with progressive hyperintense fill-in was observed in 31 lesions (91%). Two of 10 small and 1 of 20 medium lesions showed complete fill-in within 10 s, and three small and one medium lesions within 45 s after the onset of PNE. In no cases of hemangioma was immediate homogenous hyperintensity observed without preceding PNE. In conclusion, temporal resolution of less than 10 s is a prerequisite for confident dynamic characterization of some hemangiomas, predominantly small hemangiomas.

Contrast Media