[Statement of the Working Group of the Germany Society on the safety of asynchronous ventricular pacemaker stimulation ].
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to J Neuzner.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
The beneficial hemodynamic effects of cardiac resynchronization in patients with intraventricular conduction delay have been demonstrated. The potential hemodynamic effects of cardiac resynchronization to compensate the pacing-induced left ventricular conduction delay in chronically paced heart failure patients are not as well established. The aim of the study was to evaluate the acute hemodynamic effects of biventricular and left ventricular pacing in chronically paced patients with advanced heart failure. Fourteen consecutive pacemaker or defibrillator patients with permanent atrial fibrillation and AV block (11 male, 3 woman, mean age: 68 +/- 7 years) were enrolled in this study. There were 5 ischemic (36%) and 9 nonischemic (64%) patients (mean left ventricular ejection fraction: 19 +/- 5%; mean end-diastolic left ventricular diameter: 71 +/- 11 mm). In all patients a right ventricular and left ventricular (via coronary sinus) pacing lead was placed. The aortic and left ventricular hemodynamic measurements were performed using a two-channel micro-tip catheter. The measurements of the aortic pulse pressure (APP) and (dP/ dtmax) were performed during right ventricular apical pacing (RVP), left ventricular (LVP), and biventricular pacing (BVP) (70 bpm). Compared to RVP, LVP and BVP increased APP and dP/dtmax (35.8 +/- 4.2 vs 43.3 +/- 4.5 and 41.2 +/- 4 mmHg; p < 0.001) and (758 +/- 56 vs 967 +/- 60 and 961 +/- 62 mmHg/s; p < 0.001). LVP and BVP showed a comparable hemodynamic response. The hemodynamic effects were not related to the width of the paced QRS complex. Every patient showed improved hemodynamics during LVP and BVP unrelated to the underlying heart disease and to the baseline level of left ventricular dysfunction. BVP and LVP pacing acutely improve contractile left ventricular function in chronically paced patients with advanced heart failure.
AIM: Intracardiac ventricular evoked-response (ER) signals detected by implanted cardioverter defibrillator (ICD) lead systems were investigated for automatic capture verification (AC). METHOD: ER signals were evaluated with an external pacing system equipped with a reduced coupling capacitance (CC=2.2 microF) in the pacing output circuit during ventricular step-down threshold testing at 0.4 ms pulse duration. Real-time pacing markers, surface ECG and intracardiac electrograms pre- and post-filtering were digitally recorded. RESULTS: Twenty consecutive patients, age 61+/-12 years, with leads from two different manufacturers were tested - 10 were implanted with acute leads (AL) and 10 with chronic leads (CL). The analysis was based on the ER amplitude during capture and on the ER-to-afterpotential ratio (SAR), with SAR>2 as the criterion for successful capture detection. ER amplitudes (median and range) were 8.1 mV (2.1-19.5 mV) for AL and 8.3 mV (3.7-14.2 mV) for CL. SAR values (median and range) were 48.0 (2.5-682.6) for AL and 13.2 (6.3-35.9) for CL, indicating that AC could successfully be applied in all patients. CONCLUSIONS: Reducing the pacing CC allows adequate ER detection for automatic capture verification on non-selected ICD lead systems. The effect of high-voltage shock treatment on ER signal detection requires further investigation.
AIM: The aim of the study was to analyze the medical history of patients with AV-nodal reentry tachycardia (AVNRT). PATIENTS AND METHODS: Between 1990 and 1999 radiofrequency catheter ablation was performed in 1,024 patients suffering from AVNRT. Data of the previous history were comprehended by questionnaire. RESULTS: 748 (73%) patients replied to the questionnaire. The interval between the first appearance of the symptoms and the catheter ablation was 4.1 +/- 1.5 years. The mean age of the patients was 55.4 years (female) and 58.7 years (male). Merely 6% of all patients had a structural heart disease. The mean duration of case history was 16.8 years. In comparison to the male patients, the assignment for female patients to catheter ablation was after a significant 7 years longer lasting anamnesis. The distribution of age showed that the first tachycardia appeared in 16% of the female patients older than 50 years of age and only in 17% younger than 20 years of age; the corresponding percentages for men were 31% and 18%. With reference to the duration of the longest tachycardia episodes and arrhythmia-related presyncopes and syncopes, women showed a more defined symptomatic. On 20% of the patients a radiofrequency catheter ablation ensued without previous antiarrhythmic treatment; 80% of the patients were treated with 2.8 different antiarrhythmic medications. Medical consultations regarding AVNRT were named as follows (mean/range): family doctor 6.1/1-250, emergency physicians 1.1/0-15, hospital 1.0/0-20. The indication for catheter ablation was set by the family doctor in 13% and by the cardiologist in 77%. Patients got their information about catheter ablation in 2.9% from acquainted persons or news services. CONCLUSION: There is no "typical" anamnesis of AVNRT patients. There is an amazingly high rate of patients with an AVNRT begin in elder stage of age and the fact of therapy delay of 7 years in behalf of women.
Nonadequate arrhythmia detection and delivery of electrical therapy is still a main problem in current implantable cardioverter defibrillator therapy. Besides supraventricular arrhythmias extra-cardiac biosignals also can cause inadequate shock delivery. The present study focuses on nonadequate arrhythmia detection due to oversensing of diaphragmatic myopotentials. Their clinical characteristics, incidence and management are presented. Three-hundred-eighty-four recipients of a transvenous cardioverter-defibrillator who were implanted and followed-up at our institution between October 1991 and June 1999 were enrolled. During a mean follow-up of 32+/-25 months a total number of 139 nonadequate episodes of arrhythmia detection due to oversensing of diaphragmatic myopotentials were observed in 33 patients (8.6%). In 11 patients a total of 32 high energy shock deliveries occurred. Oversensing of diaphragmatic myopotentials was primarily observed in patients implanted with defibrillator leads providing "integrated bipolar" sensing. The vast majority of nonadequate arrhythmia detection were observed during intrinsic bradycardia heart rate and/or antibradycardia pacing. Electrical lead failure was ruled out in every patient. In 90% of the patients with a cardioverter-defibrillator providing programmable maximal sensitivity (n=16), the reduction of maximum sensitivity was effective in preventing further episodes of nonadequate arrhythmia detection. In 48% of the patients with devices without programmable maximal sensitivity (n=17), surgery revision was necessary to solve the problem.
A patient with recurrent syncope due to polymorphic ventricular tachycardia was diagnosed with Brugada syndrome. Programmed right ventricular stimulation could not induce arrhythmia. Epicardial stimulation from a left ventricular site through the coronary sinus led to polymorphic VT. The stimulation protocol for risk stratification in Brugada syndrome is discussed.
The aim of study was to investigate the extent of myocardial injury incurred by creation of continuous RF current induced linear ablation lesions (LL; ablation of atrial fibrillation, right atrial procedure) in comparison to focal RF lesions (FL; AV node reentry tachycardia, WPW tachycardia). In 23 patients with LL (age 51.3 +/- 11.2 years, 18 men, 5 women) and in 16 patients with FL (age 53.9 +/- 5.1 years, 8 men and 8 women), levels of creatine kinase (CK), myoglobin (MG), CKMB mass (CKMB M), CKMB activity (CKMB A), and cardiac troponin T (cTnT) were determined before and 2, 4, 8, 24, and 48 hours after ablation. CKMB A was normal in 87% in LL and 100% in FL (< 6% of CK) with median maximum CK values of 214 (45-1583) U/L in LL and 36 (29-212) U/L in FL. Peak values of all parameters were significantly higher in LL than in FL. The sensitivity of cTnT was 50% in FL and 100% in LL. In FL MG, total CK, and CKMB M were abnormal in only 12.5% of cases while in LL MG and CKMB M were pathological in 100% and total CK was abnormal in 91.3% of patients. The amount of energy and number of RF applications correlated with cTnT, MG, and CKMB M (P = 0.01). In conclusion, (1) long linear RF current lesions for ablation of atrial fibrillation are associated with significantly greater myocardial injury than focal ablations. (2) In focal lesions only cTnT provided a sensitivity of 50% in the detection of myocardial injury while in linear lesions cTnT, CKMBM, and CKMB M seemed suitable for detection of RF current induced myocardial damage with 100% sensitivity. All biochemical parameters do not differentiate patients with coronary ischemia up to 48 hours after an ablation. (3) Further investigations are necessary to determine if RF current linear lesions lead to impaired atrial contractility in cases of extensive tissue damage.
Sensing of the intracardiac evoked response (ER) after a pacing stimulus has been used in implantable pacemakers for automatic verification of capture. Reliable detection of ER is hampered by large residual afterpotentials associated with pacing stimuli. This led to the development of various technological solutions, like the use of triphasic pacing pulses and low polarizing electrode systems. This study investigated the effect of reducing the coupling capacitance (CC) in the pacemaker output circuitry on the magnitude of afterpotential, and the ability to automate detection of ventricular evoked response. A CC of 2.2 microF and four different blanking and recharge time settings were clinically tested to evaluate its impact on sensing of the ventricular ER and pacing threshold. Using an automatic step-down threshold algorithm, 54 consecutive patients, aged 70 +/- 10 years with acutely (n = 27) or chronically (n = 27) implanted ventricular pacing leads were enrolled for measurement testing. Routine measurements, using a standard pacing system analyzer (PSA), were (mean +/- SD) impedance 569 +/- 155 omega, R wave amplitude baseline to peak 9.8 +/- 3.7 mV and threshold 0.9 +/- 0.7 V at 0.4-ms pulse width. This new capture verification scheme, based on a CC of 2.2 microF and recharge/blanking timing setting of 10/12 ms, was successful in 52 patients which is equivalent to a success rate of 96%. In a subgroup of 26 patients implanted with bipolar ventricular leads (10 chronic, 16 acute), data were collected in unipolar (UP) and bipolar (BP) pace/sense configurations. Also, ER signals were recorded with two different band-pass filters: a wider band (WB) of 6-250 Hz and a conventional narrow band (NB) of 20-100 Hz. WB sensing from UP lead configuration yielded statistically significant larger signal to artifact ratios (SAR) than the other settings (P < 0.01). A dedicated unipolar ER sensing configuration using a small output capacitor and a wider band-pass filter enables adequate automatic capture verification, without any restrictions on pacing lead models or pacing/sensing configurations.
AIMS: The aim of the study was to compare the defibrillation energy requirements and the probability of successful defibrillation at multiples of the minimum defibrillation energy requirements in active pectoral implantable defibrillators with single- and dual-coil lead systems. METHODS AND RESULTS: Eighty-three consecutive patients undergoing implantation of an active pectoral cardioverter-defibrillator were randomized to receive a dual- or single-coil lead system. Defibrillators of two manufacturers with a fixed tilt biphasic defibrillation waveform were used. Defibrillation energy requirements were determined using a step-down defibrillation testing protocol. According to the randomization protocol, the patients were assigned to three additional consecutive defibrillation attempts during device implantation and during pre-discharge testing of either 1.0, 1.5 or 2.0 times the determined defibrillation energy requirement. Patients presenting defibrillation energy requirements > 15 J were excluded from analysis. Eighty of 83 patients (96%) completed the study protocol. Three patients were excluded due to elevated defibrillation energy requirements. The defibrillation energy requirements in the dual- and single-coil patient groups were 8.0 +/- 3.6 J and 8.4 +/- 3.7 J (ns), respectively. A comparable percentage of study patients showed defibrillation energy requirements <10 J (dual-coil: 88% vs single-coil: 83%). Defibrillation impedance was significantly different (dual-coil: 50 +/- 5.8 Ohm; single-coil: 39.8 +/- 4.2 Ohm). Regarding the probabilities of successful defibrillation, there were no significant differences between the two patient groups. The probabilities of defibrillation at the three multiples of the defibrillation energy requirement using a dual- and single-coil lead system were 82, 89.7 and 93.6 and 77.8, 94.1 and 95.8%, respectively (P=0.88, P=0.42, P=0.62, respectively). CONCLUSIONS: Dual- and single-coil active pectoral defibrillator systems show no difference in defibrillation energy requirements and no difference in the probability of successful defibrillation at multiples of the minimum defibrillation energy requirement. The use of more simplified defibrillator lead systems may contribute to a future lead design focusing on improvement in lead durability.
AIMS: Thermal injury of subendocardial tissue leads to a release of electrolytes and free radicals from the intracellular site creating a change in electrochemical potential (eP) between the distal and the proximal catheter tip electrodes. The aim of the study was to verify the detection of ablation-induced release of electrolytes and free radicals and to assess the suitability of control-line energy delivery at ablation by measuring eP. METHODS AND RESULTS: In vitro tests under constant flow conditions were performed in a 101 bath of physiological saline solution or bovine blood. Endomyocardial preparations of fresh bovine hearts were used. Closed-loop temperature-controlled, irrigated and closed-loop eP-controlled ablations were performed. In vivo animal investigations were performed in six anaesthetized and ventilated pigs. The existence of the eP was established in the tank model and was confirmed in animal investigations. High correlations were found between eP and catheter tip temperature (r=0.87) and between maximum eP and induced lesion size (r=0.85). Also a high correlation (r=0.85, P<0.001) was found between eP and lesion volume. CONCLUSIONS: Control of energy delivery during RF ablation by the measurement of eP is feasible. In comparison with temperature controlled RF ablation, ablation guided by eP-measurement revealed a superior correlation with induced lesion size. Especially during cooled radiofrequency catheter ablation eP is the only parameter for control of energy delivery.
AIMS: This report describes the initial clinical results with a newly designed guiding catheter and an 'over the wire' pacing lead based on angiolasty technology to stimulate the left ventricle using the transvenous route via the coronary sinus (OTW-CV lead). METHODS AND RESULTS: In 75% of the 15 patients (6 males, 9 females, mean age of 53 +/- 9 years) with congestive heart failure, access to coronary sinus required less than 2 min; in one patient. the attempt failed. Mean R wave amplitudes plus or minus the standard deviation, measured at apical, mid-ventricular and basal positions the anterior (11.4 +/- 9.2, 10.8 +/- 6.2, 9.3 +/- 6.3 mV) and lateral or posterior veins (10.1 +/- 10.7, 8.6 +/- 6.4, 7.7 +/- 4.3 mV) showed a trend favouring the apex without statistical significance. Pacing impedance, measured at the same sites and vein tributaries, ranged from 670 +/- 191 to 915 +/- 145 ohms. Pacing thresholds measured at apical and mid ventricular sites were significantly lower than at the base in the anterior vein 2.5 +/- 2.8 and 2.8 +/- 1.8 vs 5.6 +/- 2.7 V at 0.5 ms, P<0.001). Thresholds in the lateral/posterior veins showed a similar trend but did not reach statistical significance (3.0 +/- 1.7, 3.6 +/- 1.4 +/- 1.8 V at 0.5 ms). In patients, in whom thresholds were determined in more than one vein, the 'best' mean threshold was 1.6 +/- 0.7 V. CONCLUSION: The new 'over the wire' lead and guiding catheter system allows uncomplicated access to the coronary sinus and the depth of the coronary vein tributaries. Left ventricular sensing and pacing thresholds are acceptable for chronic use in implanted cardiac rhythm management systems.
A 45-year-old man experienced arterial thromboembolism to the right leg requiring surgical restoration of blood flow. Transesophageal echocardiography (TEE) was performed to determine the source of embolism and identified a localized atherosclerotic lesion in the distal ascending aorta with an adherent, highly mobile thrombus. The patient underwent surgery with removal of the atherosclerotic plaque and attached thrombus, and resection of the adjacent aortic wall. This case illustrates an unusual location for a complex atherosclerotic lesion in the ascending aorta, and points out the opportunity for remedial surgery once a symptomatic embolus has occurred.
Explore the source record for details and available documents.
The automated measurement of the main electrical parameters of pacemakers, such as battery voltage, current drain, pacing impedance, sensing levels, and pacing thresholds enables a continuous monitoring of the adequate functioning of the implanted device. New technologies in device interrogation, data transfer, and patient alert functions will enhance therapy safety significantly by the immediate detection of all, including transient, device malfunctions. The introduction of this technology will result in major changes in follow-up of patients with pacemakers. Technically we are very close to the goal of a fully automated pacemaker, although clinical acceptance lags behind. Clinical studies are necessary to demonstrate the beneficial effects of automated device functions, with regard to the main rationales for pacemaker automatization: increased patient safety, improved quality of life, and an improvement in the cost-benefit ratio in pacemaker therapy.
BACKGROUND: In about a third of cases of recurrent syncope a diagnosis cannot be established despite extensive cardiovascular and neurologic testing. In patients without underlying heart disease the sensitivity of conventional diagnostic testing is low. CASE REPORT: A 33-year-old male patient underwent implantation of a loop recorder (Reveal) after negative neurological and cardiovascular testing. One month after implantation sinus node arrest could be documented during a presyncope. The patient underwent pacemaker implantation and remains asymptomatic since then. CONCLUSION: In patients with syncope and a negative conventional diagnostic workup the implantable loop recorder is a helpful and cost-effective diagnostic tool.
HISTORY: Some weeks previously a 34-year old athlete, specializing in the triathlon, had 6 syncopes in one day. They had caused abrasions and contusions resulting from the falls. At another hospital paroxysmal atrial fibrillation had been diagnosed and treatment with disopyramide (2 x 200 mg) initiated, but she had about 15 further syncopes within 2 weeks. She was admitted for establishing their cause. INVESTIGATIONS: Initial ECGs and neurological examination failed to provide a diagnosis and she was discharged with an "event recorder". DIAGNOSIS, TREATMENT AND COURSE: Three weeks after discharge she had another syncope. The event recorder was activated by the patient's partner and revealed polymorphous ventricular tachycardia. She underwent extensive invasive cardiological tests, including a right ventricular biopsy, but no abnormality was demonstrated. However, a provocation test with ajmaline produced ST segment elevations in V1 and V2 typical of the syndrome previously described by the Brugadas (right bundle branch block, precordial ST elevations in V1-V3 and sudden cardiac death). A cardioverter-defibrillator was implanted. During the subsequent observation period of 2 month the ICD delivered one countershock, triggered by the onset of polymorphous ventricular tachycardia with syncope. CONCLUSION: In patients with serious ventricular arrhythmias but no diagnostic findings, including a normal resting ECG, a drug provocation test should be performed to exclude a Brugada syndrome.
In the current clinical cardiac electrophysiology well-defined and effective concepts regarding the diagnostic and treatment of cardiac arrhythmias have been introduced. A further improvement in the cost-benefit and the cost-effectiveness relationships in several fields of cardiac electrophysiology depends on the future technical progress and on the results of ongoing and future scientific studies. On the other side very cost-saving electrophysiological treatments had been developed; the broader clinical use of these treatments is a possibility to optimize the costs for patients' care with cardiac arrhythmias.