PubMed Health⌕ Search

Biomedical subjects

J Numminen

Publications and source records attributed to J Numminen.

11 recordsLinked to original sources

Dorsal penile nerve stimulation elicits left-hemisphere dominant activation in the second somatosensory cortex.

Activation of peripheral mixed and cutaneous nerves activates a distributed cortical network including the second somatosensory cortex (SII) in the parietal operculum. SII activation has not been previously reported in the stimulation of the dorsal penile nerve (DPN). We recorded somatosensory evoked fields (SEFs) to DPN stimulation from 7 healthy adults with a 122-channel whole-scalp neuromagnetometer. Electrical pulses were applied once every 0.5 or 1.5 sec to the left and right DPN. For comparison, left and right median and tibial nerves were stimulated alternatingly at 1.5-sec intervals. DPN stimuli elicited weak, early responses in the vicinity of responses to tibial nerve stimulation in the primary somatosensory cortex. Strong later responses, peaking at 107-126 msec were evoked in the SII cortices of both hemispheres, with left-hemisphere dominance. In addition to tactile processing, SII could also contribute to mediating emotional effects of DPN stimuli.

Adult↗

Reliability of acoustic rhinometry.

In recent years increasing evidence has been provided on frequent simultaneous coexistence of inflammatory diseases and allergies in upper and lower airways. To achieve a good standard of measurement of upper airways, an objective method should be used. A total of 48 nasal cavities with nasal stuffiness associated with chronic sinusitis were measured with acoustic rhinometry (AR) and High-resolution computer tomography volumetry (HRCTV). Comparison of volumes and minimum cross-sectional areas measured with these methods was performed. The volumes measured from the nostril with both methods were the anterior (0-10 mm), middle (11-40 mm) and posterior (41-70 mm) volumes. The AR cross-sectional area curve was analysed based on two minimal notches corresponding to local minimal areas. A series of 1-mm coronal CT images without intervening gaps were made and analysed based on two minimal voxel values, which were later converted to cross-sectional areas corresponding to local, minimum cross-sectional areas (MCA). Furthermore, the distances of these 2 MCAs from the nostril were also measured. Strong statistically significant (P < 0.05) correlations were found between AR and computer tomography volumetry (CTV) volumes in the anterior (r = 0.83) and middle (r = 0.77) parts of the nasal cavity. In the posterior part of the nasal cavity a statistically significant (P < 0.05) correlation was also found (r = 0.62). Good agreements between the AR and CTV volumes in the anterior and middle parts of the nasal cavities were confirmed with Bland-Altman plots. Correlations among the MCAs were weaker (r = 0.59 and r = 0.55). Our results suggest that the reliability of AR appears sufficient for clinical and scientific use in the nasal cavities. Reliability is very good in the anterior and middle parts of the nasal cavities, while strong conclusions based on evaluation of the posterior part should be avoided due to decreasing accuracy.

Adult↗

Speaking modifies voice-evoked activity in the human auditory cortex.

The voice we most often hear is our own, and proper interaction between speaking and hearing is essential for both acquisition and performance of spoken language. Disturbed audiovocal interactions have been implicated in aphasia, stuttering, and schizophrenic voice hallucinations, but paradigms for a noninvasive assessment of auditory self-monitoring of speaking and its possible dysfunctions are rare. Using magnetoencephalograpy we show here that self-uttered syllables transiently activate the speaker's auditory cortex around 100 ms after voice onset. These phasic responses were delayed by 11 ms in the speech-dominant left hemisphere relative to the right, whereas during listening to a replay of the same utterances the response latencies were symmetric. Moreover, the auditory cortices did not react to rare vowel changes interspersed randomly within a series of repetitively spoken vowels, in contrast to regular change-related responses evoked 100-200 ms after replayed rare vowels. Thus, speaking primes the human auditory cortex at a millisecond time scale, dampening and delaying reactions to self-produced "expected" sounds, more prominently in the speech-dominant hemisphere. Such motor-to-sensory priming of early auditory cortex responses during voicing constitutes one element of speech self-monitoring that could be compromised in central speech disorders.

Adult↗

Differential effects of overt, covert and replayed speech on vowel-evoked responses of the human auditory cortex.

Recent magnetoencephalographic studies showed that speaking dampens voice-evoked activity in the human auditory cortex. To further characterize this audio-vocal interaction, neuromagnetic responses to short tape-recorded probe vowels were measured while subjects were vocalizing long (8 s) 'background' vowels either aloud or silently, or while both probe and background vowels were replayed from tape. Auditory cortex responses peaking at 100 ms (M100) were delayed and dampened bilaterally relative to a background-free control during both overtly spoken and replayed long vowels, identifying auditory interference as the main cause for these modifications. During covert speech M100 peaked later for matching than non-matching probe/background vowels in the speech-dominant left hemisphere. Thus, voiceless 'inner' speaking is sufficient to modify utterance-specific processing in the human auditory cortex.

Adult↗

Subject's own speech reduces reactivity of the human auditory cortex.

Previous studies on monkeys have shown that uttering-related cortical areas exert an inhibitory effect on the auditory cortex, and cerebral blood-flow analyses on humans have revealed modulation of the activity of the auditory cortex during own speech. To study this modulation on a millisecond time scale, we recorded neuromagnetic evoked responses to short 1-kHz tones while the subjects were reading silently and aloud. The 100-ms response (M100) of the auditory cortex was delayed by 10-21 ms and its amplitude was dampened by 44-71% during reading aloud compared with reading silently. This effect was more prominent in responses to ipsilateral than contralateral tones, possibly due to a sum effect of diminished ipsilateral input to the cortex and decreased transcallosal excitation.

Acoustic Stimulation↗

Semi-automatic segmentation of computed tomographic images in volumetric estimation of nasal airway.

The objective of this study was to determine nasal cavity volumes and cross-sectional profiles from segmented coronal high-resolution computed tomography (HRCT) images. Pathological mucosal changes and congenital sinonasal variants were quantitated and three-dimensional (3D) images for determining sinonasal airway diseases evaluated by using the new semiautomatic segmentation software, Anatomatic. Anterior to posterior cross-sectional profiles of the sinonasal airway were obtained from acoustic rhinometry and segmented coronal HRCT images and compared in five patients having complaints of nasal obstruction and chronic sinusitis. Results showed that accurate volumes of air spaces in the nasal cavity and paranasal sinuses were obtained. When compared, the cross-sectional profiles of the nasal cavities obtained from acoustic rhinometry and the segmentation technique were similar in the anterior portion, but differed in the posterior portion. The results obtained by coronal HRCT and segmentation were more reliable than those produced with acoustic rhinometry. 3D images acquired from segmented images were found to help make a good pre-operative assessment of the whole sinonasal compartment. Segmentation and volumetric analysis using the Anatomatic technique also proved to be well suited to the evaluation of the nasal cavity and paranasal sinus geometry in patients with sinonasal diseases.

Acoustics↗

Distributions and sources of magnetoencephalographic K-complexes.

Whole-head magnetoencephalographic (MEG) and midline electroencephalographic (EEG) signals were simultaneously recorded from 6 subjects during drowsiness and sleep to define the topography and source distribution of K-complexes. In light sleep, K-complexes were also triggered by infrequent tones. Distributions of spontaneous and triggered magnetic K-complexes did not differ systematically, nor did those evoked by right- and left-ear stimuli, but there were large intra- and interindividual differences. Minimum-norm estimates and current dipoles were used to characterize the source currents. Current direction and distribution varied remarkably between the K-complexes appearing in similar situations. In one subject, most K-complexes were adequately modelled with two current dipoles which were situated in the left and right inferior parietal lobes. In other subjects, the current distributions were more complex, suggesting several brain regions to be active during one K-complex; the dominant foci were in frontal and parietal lobes. Our results suggest that the K-complex is not a stereotyped response of the cortex to internal or external stimuli, comparable to evoked responses, but a diffuse and variable cortical reaction during which large areas of cortex may be active.

Adult↗

Transformation of multichannel magnetocardiographic signals to standard grid form.

Multichannel magnetocardiographic (MCG) recordings with fixed sensor arrays are not directly comparable with single-channel measurements carried out at standard grid locations. In addition, comparison of data obtained with different types of magnetometers is difficult. We present a method for transforming multichannel measurements to the standard-grid format. The minimum-norm estimate (MNE) of the source current distribution in the body is calculated, and the desired field components in standard grid points are then computed from the MNE. We measured three subjects with both a 24-channel and a single-channel instrument. The signals extrapolated from the multichannel measurements corresponded quite well to the single-channel data registered at the standard grid locations, especially in those grid points that were covered by the 24-channel device. The signal-amplitude-weighted correlations between the extrapolated and directly measured signals were 0.73-0.87. In simulations with ideal measurement geometry but with a realistic amount of random noise in the signals, we obtained a 0.99 correlation. It was also found that the method is relatively tolerant to errors in the location and orientation of the multichannel magnetometer. For example, a simulated 20-mm displacement in the location of the sensor array caused only a 3% decrease in the correlation, and when it was rotated and tilted by 10 degrees C, the correlation decreased by 5%. The basic advantage of our extrapolation method is its physiologic nature: the method is based on the mathematical modeling of the source current distribution, rather than on direct constraints applied to the magnetic field.

Adult↗

Nasal airway volumetric measurement using segmented HRCT images and acoustic rhinometry.

Semiautomatic segmentation methods using High Resolution Computed Tomography (HRCT) or Magnetic Resonance Imaging give accurate and reproducible volumetric measurements in various intracranial diseases. In this prospective study, for the first time in literature, with the help of a new semiautomatic segmentation technique and coronal HRCT, we correlated the volumes and cross-sectional areas of the nasal cavity with those obtained by clinical acoustic rhinometry in 14 patients with chronic sinusitis. The measurements obtained by both techniques showed statistically significant correlations between volumes in the anterior and middle parts, but statistically poor correlations between the volumes in the posterior part of the nasal cavity. Coronal HRCT and our new microcomputer applicable semiautomatic segmentation software proved compatible with daily clinical practice. Based on the promising results of our study, we recommend the use of this technique in the validation studies of acoustic rhinometry and in complicated cases as a complementary examination in the evaluation of nasal cavity.

Acoustics↗