Single-trial estimation of multichannel evoked-potential measurements.

A method for single-trial estimation of multichannel evoked potentials is presented. The proposed method is based on the regularized least squares scheme. The spatial correlation between the channels is used as additional information in the estimation procedure. Amplitude estimates obtained with the proposed method is compared with the estimates calculated without using the spatial information. The performance of the method is evaluated using simulated and real data of P300 responses measured using auditory stimuli. The multichannel approach is shown to give realistic and comparable information about the amplitude differences of the P300 peak between different channels.

Action Potentials↗

A new computational approach for cortical imaging.

Estimation of current or potential distribution on the cortex is used to obtain information about neural sources from the scalp recorded electroencephalogram. If the active sources in the brain are superficial, the estimated field distribution on the cortex also yields information about the active source configuration. In these cases, these methods can be used as source localization methods. In this study, we concentrate on finite-element-based cortex potential estimation. Usually these methods require surface interpolation of the recorded voltages at the electrodes onto the entire scalp surface. We propose a new computational approach which does not require the use of surface interpolation but does it implicitly and uses only the recorded data at the electrodes. We refer to this method as the systematic approach (SA). We compare the SA with the surface interpolation approach (IA) and show that the SA is able to produce somewhat better accuracy than the IA. However, the main asset is that the sensitivity of the cortical potential maps to the regularization parameter is significantly lower than with the IA.

Brain Mapping↗

Effects of electrode properties on EEG measurements and a related inverse problem.

A trend in EEG measurements is to increase the number of measurement electrodes in order to improve the spatial resolution of the recorded voltage distribution at the scalp. It is assumed that this would implicate better accuracy in the EEG inverse estimates. However, this does not necessarily hold. The reason for this is that the electrodes create a well conducting shunting "layer" on the scalp which affects the voltage distribution. This may decrease the information obtained and may therefore worsen the inverse estimates. Electrodes in EEG inverse problems are commonly modeled as point electrodes. This model cannot take into account the possible shunting effect of the electrodes. In this study the measurement electrodes are modeled using the so-called complete electrode model which takes into account the actual size of the electrode, the contact impedance between the skin and the electrode and also the shunting effect of the electrodes. In this paper the effects of the electrode size and the contact impedance on the voltage distribution are studied by simulations. It is shown that, depending on the size and the contact impedance of the electrodes, increasing the number of electrodes does not necessarily improve the accuracy of the inverse estimates. We also conclude that the use of the point electrode model is quite adequate in normal EEG studies. The use of a complete electrode model is necessary if electrodes cover more than 50% of the surface area.

Electric Impedance↗

Effects of local skull inhomogeneities on EEG source estimation.

The accuracy of the head model affects the solutions of the EEG inverse problems. If a simple three-sphere model and standard conductivity values for brain, skull and scalp regions are used, significant errors may occur in the dipole localisation. One of the most sensitive head model parameters is the conductivity of the skull. A realistic three-dimensional finite-element model provides a method to study the effect of inhomogeneities of the skull on the solutions of EEG inverse problems. In this paper the effect of a local skull conductivity inhomogeneity on source estimation accuracy is analyzed by computer simulations for different numbers of electrodes. It is shown that if the inhomogeneity of the skull conductivity is not taken into account, localisation errors of approximately 1 cm can be encountered in the equivalent current dipole estimation. This modelling error introduces a bias to the solution which cannot be compensated by increasing the number of electrodes.