PubMed Health⌕ Search

Biomedical subjects

J O de Lorge

Publications and source records attributed to J O de Lorge.

7 recordsLinked to original sources

Lack of behavioral effects in the rhesus monkey: high peak microwave pulses at 1.3 GHz.

The current safety standards for radiofrequency and microwave exposure do not limit the peak power of microwave pulses for general or occupational exposures. While some biological effects, primarily the auditory effect, depend on pulsed microwaves, hazards associated with very high peak-power microwave pulses in the absence of whole-body heating are unknown. Five rhesus monkeys, Macaca mulatta, were exposed to peak-power densities of 131.8 W/cm2 (RMS) while performing a time-related behavioral task. The task was composed of a multiple schedule of reinforcement consisting of three distinct behavioral components: inter-response time, time discrimination, and fixed interval. Trained monkeys performed the multiple schedule during exposure to 1.3-GHz pulses at low pulse-repetition rates (2-32 Hz). No significant change was observed in any behavior during irradiation as compared to sham-irradiation sessions. Generalization of these findings to experimental results with higher peak-power densities, other pulse rates, different carrier frequencies, or other behaviors is limited.

Animals↗

A circular waveguide irradiation system for nonhuman primates: design and dosimetry.

A 275-MHz exposure system, consisting of a circular waveguide irradiator and a transparent plastic animal cage, has been developed to accommodate rhesus monkeys weighing up to 15 kg. The vertically oriented waveguide is composed primarily of stainless steel and is fitted with an inner cage fabricated from a tubular section of acrylic plastic. Circularly polarized electromagnetic energy at 275 MHz, either pulsed or continuous wave (CW), can be propagated from the removable top section of the waveguide. The cage is designed to function as the monkey's permanent home. It is fitted with a lever-actuated behavioral performance device on which the monkey responds according to a predetermined schedule to obtain a daily food ration. The system can be adapted to provide for the collection of metabolic and physiologic data as well. Dosimetric measurements were conducted with six rhesus monkeys weighing 3.0-7.2 kg and with a 4-kg model. The dosimetric results show that about one-third of the net incident energy is absorbed by a subject in this system at a normalized specific absorption rate (SAR) of 0.33 (W/kg)/(mW/cm2).

Animals↗

Operant behavior and colonic temperature of Macaca mulatta exposed to radio frequency fields at and above resonant frequencies.

Five food-deprived rhesus monkeys were exposed to 225-MHz continuous-wave, and 1.3-GHz, and 5.8-GHz pulsed radiation to determine the minimal power densities affecting performance. The monkeys were trained to press a lever (observing-response) thereby producing signals that indicated availability of food. In the presence of the aperiodically appearing food signals, a detection response on a different lever was reinforced by a food pellet. Continuous, stable responding during 60-min sessions developed and was followed by repeated exposures to radiofrequency radiation. The subjects, restrained in a Styrofoam chair, were exposed to free-field radiation while performing the task. Colonic temperature was simultaneously obtained. Observing-response performance was impaired at increasingly higher power densities as frequency increased from the near-resonance 225 MHz to the above-resonance 5.8 GHz. The threshold power density of disrupted response rate at 225 MHz was 8.1 mW/cm2; at 1.3 GHz it was 57 mW/cm2, and at 5.8 GHz it was 140 mW/cm2. These power densities were associated with reliable increases in colonic temperatures above sham-exposure levels. The mean increase was typically in the range of 1 degree C, and response-rate changes were not observed in the absence of concomitant temperature increases. In these experiments increase of colonic temperature was a much better predictor of behavioral disruption than was either the power density of the incident field or estimates of whole-body-averaged rates of energy absorption.

Animals↗

Behavioral detection of 60-Hz electric fields by rats.

Rats partially deprived of food were trained individually to press a lever in the presence of a vertical, 60-Hz electric field and not to press in its absence. Correct detections that occurred during brief, 3- or 4-s trials occasionally produced a food pellet. The probability of detecting the field was found to increase as field strength increased. The threshold of detection, ie, the field strength required for detections at a probability of 0.5 after correction for errors, was generally between 4 and 10 kV/m. The range of field strengths between almost zero and almost 100% correctness of detection was approximately 8 kV/m. A logistic function provided a good description of the increase in the detection probability with increasing field strength. These performances occurred reliably in 19 rats, some of which were studied for 2 years. Control procedures showed that the behavior required that the rat be in the electric field; the behavior was not controlled by any of several potentially confounding variables.

Animals↗

Observing-responses of rats exposed to 1.28- and 5.62-GHz microwaves.

The effects of microwave irradiation at two different frequencies (1.28 and 5.62 GHz) on observing-behavior of rodents were investigated. During daily irradiation, eight male hooded rats performed on a two-lever task; depression of one lever produced one of two different tones and the other lever produced food when depressed in the presence of the appropriate tone. At 5.62 GHz, the observing-response rate was not consistently affected until the power density approximated 26 mW/cm2 at 1.28 GHz, the observing-response rate of all rats was consistently affected at a power density of 15 mW/cm2. The respective whole-body specific absorption rates (SARs) were 4.94 and 3.75 W/kg. Measurements of localized SAR in a rat-shaped model of simulated muscle tissue revealed marked differences in the absorption pattern between the two frequencies. The localized SAR in the model's head at 1.28 GHz was higher on the side distal to the source of radiation. At 5.62 GHz the localized SAR in the head was higher on the proximal side. It is concluded that the rat's observing behavior is disrupted at a lower power density at 1.28 than at 5.62 GHz because of deeper penetration of energy at the lower frequency, and because of frequency-dependent differences in anatomic distribution of the absorbed microwave energy.

Animals↗