Magnification survey and spot view mammography with a new microfocus X-ray unit: detail resolution and radiation exposure.

The aim of our study was to evaluate a mammography unit capable of magnification of up to fourfold at an equivalent or lower dose than with current systems. A prototype mammography tube with an electron-beam-focusing technology resulting in a focal spot size of 40-120 micro m was combined with a highly intensifying screen-film system. To evaluate contrast-detail resolution, phantom radiographs were performed with the prototype magnification mammography system using a magnification factor of 1.7 for survey views and a magnification factor of 4.0 for spot views. They were compared with unmagnified survey views and magnification spot views (magnification factor 1.9) of a state-of-the-art mammography system. The radiation exposure was measured and mean glandular doses were calculated. The contrast-detail resolution with both prototype (m = 1.7) and conventional (m = 1.1) survey views was equivalent while the entrance dose and the mean glandular dose were approximately 50 % lower with the prototype. For spot views, the contrast-detail resolution was substantially higher for the prototype than for conventional magnification while the dose was equivalent. Dose reduction and improved detail resolution are possible with this new technology.

Acrylic Resins↗

MR arthrography of the shoulder with gadopentetate dimeglumine: influence of concentration, iodinated contrast material, and time on signal intensity.

OBJECTIVE: MR arthrography of the shoulder with gadopentetate dimeglumine has been proved to be valuable in the diagnosis of injuries of the rotator cuff and glenoid labrum. To date, no standard protocol for the concentration of gadopentetate dimeglumine and the volume of iodinated contrast material used for intraarticular injection exists. This study compared the intraarticular signal intensities achieved with three different MR arthrography protocols with respect to the volume of iodinated contrast material, the concentration of gadopentetate dimeglumine, and the interval between injection of contrast material and the MR study. SUBJECTS AND METHODS: MR arthrography was performed with three different protocols in 38 patients (26 men, 12 women). Patients examined with protocol 1 received an intraarticular injection of 5 ml of iotrolan and 5 ml of a 5 mmol/l solution of gadopentetate dimeglumine, resulting in a gadopentetate dimeglumine concentration of 2.5 mmol/l. Patients in protocol 2 received only 0.5 ml of iotrolan plus 12 ml of a 10 mmol/l solution of gadopentetate dimeglumine, leading to a 10 mmol/l concentration. The interval between injection and MR imaging for patients in protocols 1 and 2 was 30-45 min. Patients in protocol 3 received an intraarticular injection of 10 ml iotrolan and 1 ml of a 500 mmol/l solution of gadopentetate dimeglumine, resulting in an intraarticular concentration of gadopentetate dimeglumine of 45 mmol/l. MR examinations were performed between 20 and 360 min after administration of contrast material. Patients in protocol 3 had additional conventional and CT arthrography within 30 min after injection. The contrast-to-noise ratio of the intraarticular signal intensity was calculated for all protocols. RESULTS: The contrast-to-noise ratio (mean +/- SD) was 22.7 +/- 7.4 for the 2.5 mmol/l solution (protocol 1), 47.5 +/- 11.9 for the 10 mmol/l solution (protocol 2), and 9.9 +/- 3.1 for the 45 mmol/l solution (protocol 3) within 1 hr after injection. For protocol 3, an increase in contrast-to-noise ratio was observed after 90-180 min (53.5 +/- 12.7), followed by a decrease in contrast-to-noise ratio after 180 min (17.1 +/- 8.2). The image quality of conventional, CT, and MR arthrography (90-180 min after injection) was good in all cases of protocol 3. CONCLUSION: For MR arthrography performed within 1 hr after injection, protocol 2 is sufficient. The optimal time frame for protocol 3 is between 1.5 and 3 hr after joint puncture. Protocol 3 allows the prior performance of conventional and CT arthrography. Therefore, the addition of 1 ml of a 500 mmol/l solution of gadopentetate dimeglumine to 10 ml of iodinated contrast material is advisable if a subsequent MR study is anticipated.

Adult↗

Subtle gastric abnormalities in a canine model: detection with low-dose imaging with storage phosphors and its equivalence to conventional radiography.

The authors compared low-dose (32% of standard exposure) storage phosphor digital imaging (system resolution: 0.2-mm pixels, 10 bits) with isovoltage 75-kVp conventional radiography (standard exposure) in the detection of subtle simulated gastric abnormalities by using air contrast barium studies. Subtle simulated abnormalities (3-7-mm polyps, 4-15-mm ulcer craters, 4-11-mm-diameter edema, and 11-12-mm linear ulcers) were produced in resected canine stomachs. Receiver operating characteristic analysis of 1,800 observations by six readers indicated that the digital images with and without high-frequency edge enhancement were equivalent to conventional radiographs (mean receiver operating characteristic areas [+/- standard deviation]: 0.76 +/- 0.06, 0.78 +/- 0.04, and 0.77 +/- 0.04, respectively). The accuracy of the diagnosis was equivalent for all three modalities. The following mean accuracies of negative and positive responses, respectively, for unenhanced digital, edge-enhanced digital, and conventional images were determined: 0.71 +/- 0.05 and 0.41 +/- 0.07, 0.71 +/- 0.04 and 0.51 +/- 0.09, and 0.68 +/- 0.04 and 0.43 +/- 0.05. It was concluded that low-dose storage phosphor air-contrast barium studies were equivalent to conventional radiography in the detection of subtle gastric abnormalities.

Animals↗

[Detection of insufficiencies of enteroenteral anastomoses following gastrectomies by studies with water soluble contrast media--time and study quality].

We examined, out of a total of 539 gastrectomies, 50 suture insufficiencies in respect of localisation and size, period elapsed since surgery, and duration of manifestation. The quality of the examination was assessed and compared with the diagnostic information supplied. Only 70% of the insufficiencies were detected within the first five days. A leak can occur as late as one month after surgery (maximum period). One-quarter of the insufficiencies were detected during repeat examinations. Hence, the indication for further follow-up checks should be liberal if there is any clinical suspicion. Insufficiencies of oesophagojejunal anastomosis predominate (37). These are followed by the insufficiencies of the blind closed jejunum loop. There is no noticeable influence of the quality of examination (within the range of variation at our institute) on the diagnosis of the insufficiency.