PubMed Health⌕ Search

Biomedical subjects

J Ophir

Publications and source records attributed to J Ophir.

At least 19 recordsLinked to original sources

Elastographic image quality vs. tissue motion in vivo.

Elastography is a noninvasive method of imaging tissue elasticity using standard ultrasound equipment. In conventional elastography, axial strain elastograms are generated by cross-correlating pre- and postcompression digitized radio frequency (RF) echo frames acquired from the tissue before and after a small uniaxial compression, respectively. The time elapsed between the pre- and the postcompression frames is referred to as the interframe interval. For in vivo elastography, the interframe interval is critical because uncontrolled physiologic motion such as heartbeat, muscle motion, respiration and blood flow introduce interframe decorrelation that reduces the quality of elastograms. To obtain a measure of this decorrelation, in vivo experimental data (from human livers and thyroids) at various interframe intervals were obtained from 20 healthy subjects. To further examine the effect of the different interframe intervals on the elastographic image quality, the experimental data were also used in combination with elastographic simulation data. The deterioration of elastographic image quality was objectively evaluated by computing the area under the strain filter (SF) at a given resolution. The experimental results of this study demonstrate a statistical exponential behavior of the temporal decay of the echo signal cross-correlation amplitudes from the in vivo tissues due to uncontrollable motion. The results also indicate that the dynamic range and height of the SF are reduced at increased interframe intervals, suggesting that good objective image quality may be achieved provided only that a high frame rate is maintained in elastographic applications.

Acoustics↗

A quantitative comparison of modulus images obtained using nanoindentation with strain elastograms.

Tissue stiffness is generally known to be associated with pathologic changes. Ultrasound (US) elastography, on the other hand, is capable of imaging tissue strain, which may or may not be well-correlated with tissue stiffness. Hence, a quantitative comparison between the elastographic tissue strain images and the corresponding tissue modulus images needed to be performed to evaluate the usefulness of elastography in imaging tissue stiffnesss properties. Simulations were performed to demonstrate and quantify the similarities between modulus images and strain elastograms. This was followed by comparing nanoindenter-based modulus images with strain elastograms of thin slices of tissue-mimicking phantoms. Finally, some beef slices, canine prostates, ovine kidneys and breast cancers grown in mice were used to demonstrate the qualitative correspondence between modulus images and strain elastograms. The simulations and the experiments indicated that it is feasible to perform quantitative comparisons between strain images (using elastography) and modulus images on certain tissue structures and geometries. A good quantitative correspondence (correlation values of greater than 0.8) between structures in the modulus and strain images could be obtained at scales equal to or larger than 20 Qlambda (where Q is the quality factor defined as the ratio of the center frequency over the band width and lambda is the wavelength of the US system) modulus contrasts larger than 5, applied strains between 0.5% and 3% and window lengths for computing strain elastograms between 3 Qlambda and 5 Qlambda. The gelatin-phantom experiments showed lower values of correlation (values around 0.5) than with theory and simulations. The decrease in correlation was attributed to the presence of measurement noise in both strain elastography and modulus imaging, an increase of dimensionality of the problem (from 2-D to 3-D), local anisotropy, heterogeneity and nonstationarity. Experiments on real tissue slices showed further decrease in the correlation to around 0.3, possibly due to additional confounding factors such as time-dependent mechanical properties and geometrical distortions in the tissue during imaging. The work presented in this paper demonstrates that there is an intrinsic relationship between strain elastograms and the actual distribution of soft tissue elastic moduli, and bodes well for continued work in the area of elastography.

Algorithms↗

An experimental characterization of elastographic spatial resolution: analysis of the trade-offs between spatial resolution and contrast-to-noise ratio.

An experimental study of the spatial resolution in elastography was conducted. Models that involved two cylindrical inclusions arranged as a wedge were used to characterize the axial and lateral resolution of the axial strain elastograms. A study of the dependence of the spatial resolution on several factors such as the algorithmic parameters, the applied strain and the modulus contrast was performed. The axial resolution was found to show a linear dependence with respect to the algorithmic parameters, namely the window length and the window shift used for strain estimation. The lateral resolution showed a weak dependence on the algorithmic parameters. A weak dependence of the spatial resolution on factors such as the modulus contrast and the applied strain was found. The trade-offs between the spatial resolution and the elastographic contrast-to-noise ratio (CNR(e)) were then analyzed. A nonlinear trade-off between the CNR(e) and the axial and lateral resolution was shown for conventional strain estimation techniques, with the CNR(e) improving at a more than linear rate with respect to a linear degradation in the resolution. This study provided an experimental framework for characterizing the spatial resolution in elastography and facilitating a comparison of the CNR(e) with spatial resolution.

Elasticity↗

Theoretical derivation of SNR, CNR and spatial resolution for a local adaptive strain estimator for elastography.

Conventional techniques in elastography estimate the axial strain as the gradient of the displacement (time-delay) estimates obtained using cross-correlation of pre- and temporally stretched postcompression radiofrequency (RF) A-line segments. The use of a constant stretch factor for stretching the postcompression A-line is not adequate in the presence of heterogeneous targets that are commonly encountered. This led to the development of several adaptive strain estimation techniques in elastography. Yet, a theoretical framework for the image quality of adaptive strain estimation has not been established. In this work, we develop theoretical expressions for the image quality [measured in terms of the signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR) and spatial resolution] of elastograms obtained using an adaptive strain estimator developed by Alam et al. (1998). We show a linear trade-off between the SNR and axial resolution of the strain elastogram with respect to the window length used for strain estimation. The CNR shows a quadratic tradeoff with the axial resolution with respect to the window length. The SNR, CNR and axial resolution are shown to improve with the ultrasonic bandwidth.

Algorithms↗

A zero-crossing strain estimator for elastography.

A novel zero-crossing tracking strain estimator (ZCT) has been developed for elastography. This technique is based on tracking the zero-crossings between the pre- and postcompression A-lines, and does not require global or adaptive A-line stretching. For multicompression elastography, ZCT can be implemented as a tracking scheme, where a temporal track of the zero-crossings between successive radiofrequency (RF) A-lines is obtained, or as an averaging scheme, where a cumulation of the interframe strains is performed, to yield high elastographic signal-to-noise ratio (SNR). Other advantages of the scheme include fast processing and its potential to be implemented in hardware. The limitations of the technique are the need for small compression steps due to lack of robustness when large compression steps (> 3% applied compression) are used. Simulations and experiments were performed to illustrate its utility as an alternative strain-estimation technique. This technique provides lower SNR but higher contrast-to-noise ratio (CNR) than the conventional strain-estimation techniques in elastography.

Animals↗

Trade-offs between the axial resolution and the signal-to-noise ratio in elastography.

Elastography involves tracking the ultrasonic A-mode signals before and after mechanical compression of tissue to form a computed image of the local strains undergone by various tissue components. The quality of the strain estimates in elastography is typically quantified using factors such as the elastographic SNR (SNR(e)), contrast-to-noise ratio (CNR(e)), and the spatial resolution. These quality factors depend on the mechanical parameters (such as the applied strain and the boundary conditions), the acoustic parameters (such as the sonographic SNR, the center frequency, and the bandwidth), and the signal-processing parameters (such as the window length and the window separation). Theoretical developments in elastography have established functional relationships between the SNR(e) and CNR(e) and these parameters. Similarly, simulations have established empirical relationships between the axial resolution and the acoustic and signal-processing parameters. We find that a trade-off exists between the achievable SNR(e) (CNR(e)) and the axial resolution in elastography and that the trade-off occurs only with respect to the signal-processing parameters. Theoretical work on the spatial resolution accompanied with simulations and experiments were used to confirm such an observation. The trade-off between the SNR(e) (CNR(e)) and the resolution was found to be nonlinear, with large improvements in the SNR(e) being possible at the expense of small reductions in the axial resolution. All the quality factors improve with the acoustic parameters, which suggests the preferred use of transducers with high absolute bandwidths and center frequencies.

Acoustics↗

Tissue-mimicking oil-in-gelatin dispersions for use in heterogeneous elastography phantoms.

A ten-month study is presented of materials for use in heterogeneous elastography phantoms. The materials consist of gelatin with or without a suspension of microscopic safflower oil droplets. The highest volume percent of oil in the materials is 50%. Thimerosal acts as a preservative. The greater the safflower oil concentration, the lower the Young's modulus. Elastographic data for heterogeneous phantoms, in which the only variable is safflower oil concentration, demonstrate stability of inclusion geometry and elastic strain contrast. Young's modulus ratios (elastic contrasts) producible in a heterogeneous phantom are as high as 2.7. The phantoms are particularly useful for ultrasound elastography. They can also be employed in MR elastography, although the highest achievable ratio of longitudinal to transverse relaxation times is considerably less than is the case for soft tissues.

Elasticity↗

Estimating the elastographic signal-to-noise ratio using correlation coefficients.

In conventional elastography, strain is estimated from the gradient of the displacement (time-delay) estimates. The displacement estimates involve estimating the peak location of the cross-correlation function between matching pre- and post-compression A-lines. Bias errors in estimating the peak location of the cross-correlation function, amplified by the gradient operation on the displacement estimates (needed for the computation of the strain), could result in values of elastographic signal-to-noise ratio (SNR(e)) that exceed the theoretical upper bounds, thereby hindering a consistent interpretation of this parameter. These algorithmic errors have not been accounted for by the theory. We propose the use of the measured correlation coefficients in the theoretical SNR(e) expressions to estimate the SNR(e), rather than computing them directly from the elastograms. This methodology results in values of SNR(e) that are lower than the theoretical upper bounds, thereby avoiding the problems associated with computing SNR(e) directly from the elastograms. Using simulated models of uniformly elastic phantoms, a proof of principle of such an SNR(e) measure is shown.

Algorithms↗

Analysis of an adaptive strain estimation technique in elastography.

Elastography is based on the estimation of strain due to tissue compression or expansion. Conventional elastography involves computing strain as the gradient of the displacement (time-delay) estimates between gated pre- and postcompression signals. Uniform temporal stretching of the postcompression signals has been used to reduce the echo-signal decorrelation noise. However, a uniform stretch of the entire postcompression signal is not optimal in the presence of strain contrast in the tissue and could result in loss of contrast in the elastogram. This has prompted the use of local adaptive stretching techniques. Several adaptive strain estimation techniques using wavelets, local stretching and iterative strain estimation have been proposed. Yet, a quantitative analysis of the improvement in quality of the strain estimates overconventional strain estimation techniques has not been reported. We propose a two-stage adaptive strain estimation technique and perform a quantitative comparison with the conventional strain estimation techniques in elastography. In this technique, initial displacement and strain estimates using global stretching are computed, filtered and then used to locally shift and stretch the postcompression signal. This is followed by a correlation of the shifted and stretched postcompression signal with the precompression signal to estimate the local displacements and hence the local strains. As proof of principle, this adaptive stretching technique was tested using simulated and experimental data.

Elasticity↗

Elastographic imaging using staggered strain estimates.

Conventional techniques in elastography estimate strain as the gradient of the displacement estimates obtained through crosscorrelation of pre- and postcompression rf A-lines. In these techniques, the displacements are estimated over overlapping windows and the strains are estimated as the gradient of the displacement estimates over adjacent windows. The large amount ofnoise at high window overlaps may result in poor quality elastograms, thus restricting the applicability of conventional strain estimation techniques to low window overlaps, which, in turn, results in a small number of pixels in the image. To overcome this restriction, we propose a multistep strain estimation technique. It computes the first elastogram using nonoverlapped windows. In the next step, the data windows are shifted by a small distance (small fraction of window size) and another elastogram is produced. This is repeated until the cumulative shift equals/exceeds the window size and all the elastograms are staggered to produce the final elastogram. Simulations and experiments were performed using this technique to demonstrate significant improvement in the elastographic signal-to-noise ratio (SNRe) and the contrast-to-noise ratio (CNRe) at high window overlaps over conventional strain estimation techniques, without noticeable loss of spatial resolution. This technique might be suitable for reducing the algorithmic noise in the elastograms at high window overlaps.

Computer Simulation↗

Phase aberration effects in elastography.

In sonography, phase aberration plays a role in the corruption of sonograms. Phase aberration does not have a significant impact on elastography, if statistically similar phase errors are present in both the pre- and postcompression signals. However, if the phase errors are present in only one of the pre- or postcompression signal pairs, the precision of the strain estimation process will be reduced. In some cases, increased phase errors may occur only in the postcompression signal due to changes in the tissue structure with the applied compression. Phase-aberration effects increase with applied strain and may be viewed as an image quality derating factor, much like frequency-dependent attenuation or undesired lateral tissue motion. In this paper, we present a theoretical and simulation study of the effects of phase aberration on the elastographic strain-estimation process, using the strain filter approach.

Biomechanical Phenomena↗

Contrast-transfer efficiency for continuously varying tissue moduli: simulation and phantom validation.

This study consisted of two parts. In the first part, the contrast-transfer efficiency (CTE) in elastography was extended to account for continuous changes of modulus distribution. It was shown that, for a finite size background, the strain contrast approaches the modulus contrast in the case of Gaussian distributions. Thus, an increase in the CTE was obtained. For a fixed background size, it was shown that the CTE increases as the SD of the Gaussian distribution increases. This property was explained by the redistribution of strain concentrations at the inclusion/background interface. In the second part of the study, the CTE was verified experimentally. Six gelatin/agar/water-based phantoms embedding inclusions with modulus contrast varying between +/- 6 dB were manufactured. It was shown that the modulus at the interface inclusion/background was continuous and, in turn, resulted in an increase of the CTE as compared to the known case of a sharp boundary. The continuous inclusion/background interface was explained by the existence of an osmotic pressure gradient.

Agar↗

Poroelastography: imaging the poroelastic properties of tissues.

In the field of elastography, biological tissues are conveniently assumed to be purely elastic solids. However, several tissues, including brain, cartilage and edematous soft tissues, have long been known to be poroelastic. The objective of this study is to show the feasibility of imaging the poroelastic properties of tissue-like materials. A poroelastic material is a material saturated with fluid that flows relative to a deforming solid matrix. In this paper, we describe a method for estimating the poroelastic attributes of tissues. It has been analytically shown that during stress relaxation of a poroelastic material (i.e., sustained application of a constant applied strain over time), the lateral-to-axial strain ratio decreases exponentially with time toward the Poisson's ratio of the solid matrix. The time constant of this variation depends on the elastic modulus of the solid matrix, its permeability and its dimension along the direction of fluid flow. Recently, we described an elastographic method that can be used to map axial and lateral tissue strains. In this study, we use the same method in a stress relaxation case to measure the time-dependent lateral-to-axial strain ratio in poroelastic materials. The resulting time-sequenced images (poroelastograms) depict the spatial distribution of the fluid within the solid at each time instant, and help to differentiate poroelastic materials of distinct Poisson's ratios and permeabilities of the solid matrix. Results are shown from finite-element simulations.

Elasticity↗

Experimental corroboration of the nonstationary strain estimation errors in elastography.

The nonstationary variation in the noise performance of the cross-correlation-based strain estimator due to frequency-dependent attenuation and lateral and elevational signal decorrelation have been addressed theoretically in recent papers using the strain-filter approach. In this paper, we present the experimental verification and corroboration of the nonstationary effects on the strain estimation results. The accuracy and precision of the strain estimate deteriorates with lateral position in the elastogram, due to the lateral motion of tissue scatterers, and with depth, due to frequency-dependent attenuation. The results illustrate that the best strain-estimation noise performance is obtained in the focal zone of the transducer and around the axis of symmetry of the phantom.

Elasticity↗

Tradeoffs in elastographic imaging.

This paper presents the tradeoffs in elastographic imaging. Elastography is viewed as a new imaging modality and presented in terms of three fundamental concepts that constitute the basis for the elastographic imaging process. These are the tissue elastic deformation process, the statistical analysis of strain estimation and the image characterization. The first concept involves the use of the contrast transfer efficiency (CTE) that describes the mapping of a distribution of local tissue elastic moduli into a distribution of local longitudinal tissue strains. The second concept defines the elastographic system and the relationship between ultrasonic and signal processing parameters. This process is described in terms of a stochastic framework (the strain filter) that provides upper and practical performance bounds and their dependence on the various system parameters. Finally, the output image, the elastogram, is characterized by its image parameters, such as signal-to-noise ratio, contrast-to-noise ratio, dynamic range and resolution. Finite-element simulations are used to generate examples of elastograms that are confirmed by the theoretical prediction tools.

Acoustics↗

Psoriatic arthritis: interrelationships between skin and joint manifestations related to onset, course and distribution.

To assess the relationships between skin and joint disease, 70 patients with psoriatic arthritis were consecutively evaluated. Data were obtained regarding age, sex, duration of disease, age at onset, and flares of both skin and joint disease. Rheumatological assessment included morning stiffness, number of swollen, tender and deformed joints, involvement of distal interphalangeal joints (DIP), presence of dactylitis, Achilles tendinitis, and clinical lumbar and cervical involvement. Skin assessment included recording of the distribution of skin lesions and nail involvement, and grading of psoriasis severity using the PASI. The scalp was the most frequently involved site. Significant correlation was found between the PASI score and the number of deformed joints and Schober's test. The scalp score was found to correlate with the number of swollen joints, deformed joints, sausage finger and DIP involvement. Synchronous flares of skin and joint were significantly more frequent in the patients with onset of skin and joint diseases within the same year. Likewise, these patients showed a highly significant association between the PASI score and the number of tender, swollen and deformed joints, Schober's test and cervical involvement, whereas no such associations were found among patients with separate onset of skin and joint diseases.

Adolescent↗

Immediate and delayed effects of treatment at the Dead Sea in patients with psoriatic arthritis.

The purpose of this study was to evaluate the immediate and delayed effects of balneotherapy at the Dead Sea on patients with psoriatic arthritis (PsA). A total of 42 patients with PsA were treated at the Dead Sea for 4 weeks. Patients were randomly allocated into two groups: group 1 (23 patients) and group 2 (19 patients). Both groups received daily exposure to sun ultraviolet rays and regular bathing at the Dead Sea. Group 1 was also treated with mud packs and sulfur baths. Patients were assessed by a dermatologist and a rheumatologist 3 days before arrival, at the end of treatment, and at weeks 8, 16, and 28 from the start of treatment. The clinical indices assessed were morning stiffness, right and left hand grip, number of tender joints, number of swollen joints, Schober test, distance from finger to floor when bending forward, patient's self-assessment of disease severity, inflammatory neck and back pain and psoriasis area and severity index (PASI) score. Comparison between groups disclosed a similar statistically significant improvement for variables such as PASI, morning stiffness, patient self-assessment, right and left grip, Schober test and distance from finger to floor when bending forward. For variables such as tender and swollen joints, and inflammatory neck and back pain, improvement over time was statistically significant in group 1. Addition of mud packs and sulfur baths to sun ultraviolet exposure and Dead Sea baths seems to prolong beneficial effects and improves inflammatory back pain.

Arthritis, Psoriatic↗

Spectral estimators in elastography.

Like velocity, strain induces a time delay and a time scaling to the received signal. Elastography typically uses time delay techniques to indirectly (i.e. via the displacement estimate) measure tissue strain induced by an applied compression, and considers time scaling as a source of distortion. More recently, we have shown that the time scaling factor can also be spectrally estimated and used as a direct measure of strain. Strain causes a Doppler-like frequency shift and a change in bandwidth of the bandpass power spectrum of the echo signal. Two frequency shift strain estimators are described that have been proven to be more robust but less precise when compared to time delay estimators, both in simulations and experiments. The increased robustness is due to the insensitivity of the spectral techniques to phase decorrelation noise. In this paper we discuss and compare the theoretical and experimental findings obtained with traditional time delay estimators and with the newly proposed spectral methods.

Blood Flow Velocity↗