Characterization of the output for helical delivery of intensity modulated slit beams.

The UW tomotherapy workbench utilizes a convolution/superposition based dose calculation and optimization program. It specifies the energy fluence that must be delivered from each leaf for each phantom projection angle. This requires that the spectrum of the radiation emitted from the one-dimensional MLC (multileaf collimator) attached to the linear accelerator be determined. The steps involved in that process are described. The spectrum along the central axis of the slit beam was determined, as well as the softening with off-axis position. Moreover, the magnitude of the energy-fluence output had to be quantified on a per MU (monitor unit) basis. This was done for a single leaf along the central axis of the beam. Factors, which modify that energy-fluence output, were investigated. The output increases with off-axis position due to the horns of the beam. The output for a leaf of interest will also increase if additional leaves are open due to the absence of the tongue-and-groove effect and penumbra blurring. The energy-fluence increase per leaf increase by 4.9% if an adjacent leaf is open. No other factors related to the state of additional leaves were found to significantly increase the energy-fluence output for an individual leaf.

Algorithms↗

Multileaf collimator interleaf transmission.

Multileaf collimators (MLCs) have advanced past their original design purpose as a replacement for field shaping cerrobend blocks. Typically, MLCs incorporate an interlocking tongue-and-groove design between adjacent leaves to minimize leakage between leaves. They are beginning to be used to provide intensity modulation for conformal three-dimensional radiation therapy. It is possible that a critical target volume may receive an underdose due to the region of overlap if adjacent leaves are allowed to alternate between the open and closed positions, as they might if intensity modulation is employed. This work demonstrates the magnitude of that effect for a commercially available one-dimensional temporally modulated MLC. The magnitude of the transmission between leaves as a function of leaf separation was also studied, as well as the transmission as a function of leaf rotation away from the source. The results of this work were used for the design of a tomotherapy MLC. The radiation leakage considerations for a tomotherapy MLC are discussed.

Computer Simulation↗

Whole head mapping of magnetic fields following painful electric finger shock.

Painful intracutaneous electric finger shock was delivered to the fifth digit of the non-dominant hand of five healthy volunteers. Whole head evoked magnetic field maps were collected and cortical localizations were calculated using local sphere equivalent current dipole fits. MRI scans were used to identify the anatomical structures where magnetic field sources were located. Anatomically, sources were identified bilaterally in the primary somatosensory region and SII-Insula regions. Additionally, frontal operculum sources were observed contralaterally in two subjects. Temporally, an initial contralateral SI activation at 40-60 ms was followed by several SII-Insula responses over the next several hundred milliseconds (ms). These SII-Insula responses were often interspersed with additional activations of the SI region. These later responses were observed in both hemispheres.

Adult↗

The use of customized spreadsheets in radiation therapy.

A number of radiation-therapy-related uses based on a commercially available spreadsheet program have been developed at our facility. The graphics and display capabilities inherent in these spreadsheet programs allow for concise visual results. The spreadsheets are used as an independent check for several types of radiation therapy dose calculations. External beam--a spreadsheet will verify the monitor units (MU) or time required to deliver a prescribed dose to a point on an isodose line as calculated by a commercial treatment planning system. Calibration--spreadsheet programs have been developed to perform the calculations necessary for the output calibration of cobalt and high-energy photon and electron beams according to the TG-21 protocol. The user must indicate which beam, electrometer, chamber, phantom material, temperature, pressure and depth of measurement that apply. Radiosurgery--the MU per arc is calculated based on the following: the average depth per arc as obtained from a commercial radiosurgery program, the collimator size, and the prescription dose. TBI--The patient's width is entered into the spreadsheet program, which then calculates the MU needed to deliver a prescribed dose to the midline.

Humans↗