PubMed Health⌕ Search

Biomedical subjects

J P Butler

Publications and source records attributed to J P Butler.

At least 19 recordsLinked to original sources

3He lung imaging in an open access, very-low-field human magnetic resonance imaging system.

The human lung and its functions are extremely sensitive to gravity; however, the conventional high-field magnets used for most laser-polarized (3)He MRI of the human lung restrict subjects to lying horizontally. Imaging of human lungs using inhaled laser-polarized (3)He gas is demonstrated in an open-access very-low-magnetic-field (<5 mT) MRI instrument. This prototype device employs a simple, low-cost electromagnet, with an open geometry that allows variation of the orientation of the imaging subject in a two-dimensional plane. As a demonstration, two-dimensional lung images were acquired with 4-mm in-plane resolution from a subject in two orientations: lying supine and sitting in a vertical position with one arm raised. Experience with this prototype device will guide optimization of a second-generation very-low-field imager to enable studies of human pulmonary physiology as a function of subject orientation.

Administration, Inhalation↗

Linearity and time-scale invariance of the creep function in living cells.

We report here the creep function measured in three cell types, after a variety of interventions, and over three time decades (from 3 ms to 3.2 s). In each case the response conformed to a power law, implying that no distinct molecular relaxation times or time constants could characterize the response. These results add to a growing body of evidence that stands in contrast to widely used viscoelastic models featuring at most a few time constants. We show instead that the ability of the matrix to deform is time-scale invariant and characterized by only one parameter: the power law exponent that controls the transition between solid-like and liquid-like behaviour. Moreover, we validate linearity by comparison of measurements in the time and frequency domains.

Cell Movement↗

Time course of air hunger mirrors the biphasic ventilatory response to hypoxia.

Determining response dynamics of hypoxic air hunger may provide information of use in clinical practice and will improve understanding of basic dyspnea mechanisms. It is hypothesized that air hunger arises from projection of reflex brain stem ventilatory drive ("corollary discharge") to forebrain centers. If perceptual response dynamics are unmodified by events between brain stem and cortical awareness, this hypothesis predicts that air hunger will exactly track ventilatory response. Thus, during sustained hypoxia, initial increase in air hunger would be followed by a progressive decline reflecting biphasic reflex ventilatory drive. To test this prediction, we applied a sharp-onset 20-min step of normocapnic hypoxia and compared dynamic response characteristics of air hunger with that of ventilation in 10 healthy subjects. Air hunger was measured during mechanical ventilation (minute ventilation = 9 +/- 1.4 l/min; end-tidal Pco(2) = 37 +/- 2 Torr; end-tidal Po(2) = 45 +/- 7 Torr); ventilatory response was measured during separate free-breathing trials in the same subjects. Discomfort caused by "urge to breathe" was rated every 30 s on a visual analog scale. Both ventilatory and air hunger responses were modeled as delayed double exponentials corresponding to a simple linear first-order response but with a separate first-order adaptation. These models provided adequate fits to both ventilatory and air hunger data (r(2) = 0.88 and 0.66). Mean time constant and time-to-peak response for the average perceptual response (0.36 min(-1) and 3.3 min, respectively) closely matched corresponding values for the average ventilatory response (0.39 min(-1) and 3.1 min). Air hunger response to sustained hypoxia tracked ventilatory drive with a delay of approximately 30 s. Our data provide further support for the corollary discharge hypothesis for air hunger.

Adult↗

Regional rheological differences in locomoting neutrophils.

Intracellular rheology is a useful probe of the mechanisms underlying spontaneous or chemotactic locomotion and transcellular migration of leukocytes. We characterized regional rheological differences between the leading, body, and trailing regions of isolated, adherent, and spontaneously locomoting human neutrophils. We optically trapped intracellular granules and measured their displacement for 500 ms after a 100-nm step change in the trap position. Results were analyzed in terms of simple viscoelasticity and with the use of structural damping (stress relaxation follows a power law in time). Structural damping fit the data better than did viscoelasticity. Regional viscoelastic stiffness and viscosity or structural damping storage and loss moduli were all significantly lower in leading regions than in pooled body and/or trailing regions (the latter were not significantly different). Structural damping showed similar levels of elastic and dissipative stresses in body and/or trailing regions; leading regions were significantly more fluidlike (increased power law exponent). Cytoskeletal disruption with cytochalasin D or nocodazole made body and/or trailing regions approximately 50% less elastic and less viscous. Cytochalasin D completely suppressed pseudopodial formation and locomotion; nocodazole had no effect on leading regions. Neither drug changed the dissipation-storage energy ratio. These results differ from those of studies of neutrophils and other cell types probed at the cell membrane via beta(2)-integrin receptors, which suggests a distinct role for the cell cortex or focal adhesion complexes. We conclude that 1) structural damping well describes intracellular rheology, and 2) while not conclusive, the significantly more fluidlike behavior of the leading edge supports the idea that intracellular pressure may be the origin of motive force in neutrophil locomotion.

Antineoplastic Agents↗

Measuring surface-area-to-volume ratios in soft porous materials using laser-polarized xenon interphase exchange nuclear magnetic resonance.

We demonstrate a minimally invasive nuclear magnetic resonance (NMR) technique that enables determination of the surface-area-to-volume ratio (S/V) of soft porous materials from measurements of the diffusive exchange of laser-polarized 129Xe between gas in the pore space and 129Xe dissolved in the solid phase. We apply this NMR technique to porous polymer samples and find approximate agreement with destructive stereological measurements of S/V obtained with optical confocal microscopy. Potential applications of laser-polarized xenon interphase exchange NMR include measurements of in vivo lung function in humans and characterization of gas chromatography columns.

Lasers↗

Kinematically irreversible acinar flow: a departure from classical dispersive aerosol transport theories.

Current theories describe aerosol transport in the lung as a dispersive (diffusion-like) process, characterized by an effective diffusion coefficient in the context of reversible alveolar flow. Our recent experimental data, however, question the validity of these basic assumptions. In this study, we describe the behavior of fluid particles (or bolus) in a realistic, numerical, alveolated duct model with rhythmically expanding walls. We found acinar flow exhibiting multiple saddle points, characteristic of chaotic flow, resulting in substantial flow irreversibility. Computations of axial variance of bolus spreading indicate that the growth of the variance with respect to time is faster than linear, a finding inconsistent with dispersion theory. Lateral behavior of the bolus shows fine-scale, stretch-and-fold striations, exhibiting fractal-like patterns with a fractal dimension of 1.2, which compares well with the fractal dimension of 1.1 observed in our experimental studies performed with rat lungs. We conclude that kinematic irreversibility of acinar flow due to chaotic flow may be the dominant mechanism of aerosol transport deep in the lungs.

Aerosols↗

Scaling the microrheology of living cells.

We report a scaling law that governs both the elastic and frictional properties of a wide variety of living cell types, over a wide range of time scales and under a variety of biological interventions. This scaling identifies these cells as soft glassy materials existing close to a glass transition, and implies that cytoskeletal proteins may regulate cell mechanical properties mainly by modulating the effective noise temperature of the matrix. The practical implications are that the effective noise temperature is an easily quantified measure of the ability of the cytoskeleton to deform, flow, and reorganize.

Cytoskeletal Proteins↗

Respiratory effects of transient axial acceleration.

Whereas gravity has an inspiratory effect in upright subjects, transient upward acceleration is reported to have an expiratory effect. To explore the respiratory effects of transient axial accelerations, we measured axial acceleration at the head and transrespiratory pressure or airflow in five subjects as they were dropped or lifted on a platform. For the first 100 ms, upward acceleration caused a decrease in mouth pressure and inspiratory flow, and downward acceleration caused the opposite. We also simulated these experimental observations by using a computational model of a passive respiratory system based on anatomical data and normal respiratory characteristics. After 100 ms, respiratory airflow in our subjects became highly variable, no longer varying with acceleration. Electromyograms of thoracic and abdominal respiratory muscles showed bursts of activity beginning 40-125 ms after acceleration, suggesting reflex responses responsible for subsequent flow variability. We conclude that, in relaxed subjects, transient upward axial acceleration causes inspiratory airflow and downward acceleration causes expiratory airflow, but that after ~100 ms, reflex activation of respiratory musculature largely determines airflow.

Acceleration↗

alpha-Actin: disposition, quantities, and estimated effects on lung recoil and compliance.

We have investigated the basis and implications of pneumoconstriction by measuring disposition and quantities of alpha-smooth muscle actin in rat and guinea pig lungs and modeling its effects on lung recoil and compliance. A robust marker of contractility, alpha-smooth muscle actin appears in smooth muscle or myofibroblast-like cells in pleura, airways, blood vessels, and alveolar ductal tissues. In each site, we measured its transected area by immunofluorescent staining and frequency-modulated scanning confocal microscopy. We incorporated these data in a model of the parenchyma consisting of an extensive elastic network with embedded contractile structures. We conclude that contraction at any one of these sites alone can decrease parenchymal compliance by 20-30% during tidal breathing. This is due mostly to the stiffness of activated contractile elements undergoing passive cycling; constant muscle tension would have little effect. The magnitude of the effect corresponds with known responses of the lung to hypocapnia, consistent with a homeostatic function in which gas exchange is defended by redistributing ventilation away from overventilated units.

Actins↗

Selected contribution: time course and heterogeneity of contractile responses in cultured human airway smooth muscle cells.

We measured the time course and heterogeneity of responses to contractile and relaxing agonists in individual human airway smooth muscle (HASM) cells in culture. To this end, we developed a microrheometer based on magnetic twisting cytometry adapted with a novel optical detection system. Ferromagnetic beads (4.5 microm) coated with Arg-Gly-Asp peptide were bound to integrins on the cell surface. The beads were twisted in a sinusoidally varying magnetic field at 0.75 Hz. Oscillatory bead displacements were recorded using a phase-synchronized video camera. The storage modulus (cell stiffness; G'), loss modulus (friction; G"), and hysteresivity (eta; ratio of G" to G') could be determined with a time resolution of 1.3 s. Within 5 s after addition of histamine (100 microM), G' increased by 2.2-fold, G" increased by 3.0-fold, and eta increased transiently from 0.27 to 0.34. By 20 s, eta decreased to 0.25, whereas G' and G" remained above baseline. Comparable results were obtained with bradykinin (1 microM). These changes in G', G", and eta measured in cells were similar to but smaller than those reported for intact muscle strips. When we ablated baseline tone by adding the relaxing agonist dibutyryl cAMP (1 mM), G' decreased within 5 min by 3.3-fold. With relaxing and contracting agonists, G' could be manipulated through a contractile range of 7.3-fold. Cell populations exhibited a log-normal distribution of baseline stiffness (geometric SD = 2.8) and a heterogeneous response to both contractile and relaxing agonists, partly attributable to variability of baseline tone between cells. The total contractile range of the cells (from maximally relaxed to maximally stimulated), however, was independent of baseline stiffness. We conclude that HASM cells in culture exhibit a clear, although heterogeneous, response to contractile and relaxing agonists and express the essential mechanical features characteristic of the contractile response observed at the tissue level.

Cells, Cultured↗

Increased sensitivity of tryptic peptide detection by MALDI-TOF mass spectrometry is achieved by conversion of lysine to homoarginine.

Mass spectrometric techniques for identification of proteins by "mass fingerprinting" (matching the masses of tryptic peptides from a protein digest to the theoretical peptides in a database) such as matrix-assisted laser desorption ionization-time of flight (MALDI-TOF) are rapidly growing in popularity as the demand for high throughput analysis of the proteome increases. This is due, in part, to the ability to automate the technique and the rapid rate with which mass spectra may be acquired. An important factor in the accuracy of the technique is the number of tryptic peptides that are identified in the various searching algorithms that exist. The greater sequence coverage of the parent protein that is obtained, the higher the level of confidence in the identification that is determined. One impediment to high levels of sequence coverage is the bias of MALDI-TOF mass spectrometry to arginine-containing peptides. Increasing the sensitivity to lysine-containing peptides should increase the sequence coverage obtained. In order to achieve this result we have developed conditions to modify the epsilon-amine group of lysine in tryptic peptides with O-methylisourea. The conditions utilized result in the conversion of lysine to homoarginine with no modification of the amine terminus of the peptides. The sensitivity of MALDI-TOF mass spectrometry detection of peptides was increased dramatically following modification. The modification chemistry may be applied to tryptic peptide mixtures prior to desalting and spotting onto MALDI-TOF plates. This technique will be particularly useful for identifying proteins with a high lysine/arginine ratio.

Amino Acid Sequence↗

Reduced xenon diffusion for quantitative lung study--the role of SF(6).

The large diffusion coefficients of gases result in significant spin motion during the application of gradient pulses that typically last a few milliseconds in most NMR experiments. In restricted environments, such as the lung, this rapid gas diffusion can lead to violations of the narrow pulse approximation, a basic assumption of the standard Stejskal-Tanner NMR method of diffusion measurement. We therefore investigated the effect of a common, biologically inert buffer gas, sulfur hexafluoride (SF(6)), on (129)Xe NMR and diffusion. We found that the contribution of SF(6) to (129)Xe T(1) relaxation in a 1:1 xenon/oxygen mixture is negligible up to 2 bar of SF(6) at standard temperature. We also measured the contribution of SF(6) gas to (129)Xe T(2) relaxation, and found it to scale inversely with pressure, with this contribution approximately equal to 1 s for 1 bar SF(6) pressure and standard temperature. Finally, we found the coefficient of (129)Xe diffusion through SF(6) to be approximately 4.6 x 10(-6) m(2)s(-1) for 1 bar pressure of SF(6) and standard temperature, which is only 1.2 times smaller than the (129)Xe self diffusion coefficient for 1 bar (129)Xe pressure and standard temperature. From these measurements we conclude that SF(6) will not sufficiently reduce (129)Xe diffusion to allow accurate surface-area/volume ratio measurements in human alveoli using time-dependent gas diffusion NMR.

Diffusion↗

Perturbed equilibria of myosin binding in airway smooth muscle: bond-length distributions, mechanics, and ATP metabolism.

We carried out a detailed mathematical analysis of the effects of length fluctuations on the dynamically evolving cross-bridge distributions, simulating those that occur in airway smooth muscle during breathing. We used the latch regulation scheme of Hai and Murphy (Am. J. Physiol. Cell Physiol. 255:C86-C94, 1988) integrated with Huxley's sliding filament theory of muscle contraction. This analysis showed that imposed length fluctuations decrease the mean number of attached bridges, depress muscle force and stiffness, and increase force-length hysteresis. At frequencies >0.1 Hz, the bond-length distribution of slowly cycling latch bridges changed little over the stretch cycle and contributed almost elastically to muscle force, but the rapidly cycling cross-bridge distribution changed substantially and dominated the hysteresis. By contrast, at frequencies <0.033 Hz this behavior was reversed: the rapid cycling cross-bridge distribution changed little, effectively functioning as a constant force generator, while the latch bridge bond distribution changed substantially and dominated the stiffness and hysteresis. The analysis showed the dissociation of force/length hysteresis and cross-bridge cycling rates when strain amplitude exceeds 3%; that is, there is only a weak coupling between net external mechanical work and the ATP consumption required for cycling cross-bridges during the oscillatory steady state. Although these results are specific to airway smooth muscle, the approach generalizes to other smooth muscles subjected to cyclic length fluctuations.

Adenosine Triphosphate↗

Suppression of an amyloid beta peptide-mediated calcium channel response by a secreted beta-amyloid precursor protein.

Secreted isoforms of the beta-amyloid precursor protein potently enhance neuronal survival in cell cultures exposed to toxic amyloid beta peptide. Lowering of intracellular calcium levels to offset the increases in intraneuronal calcium caused by amyloid beta peptide is thought to underly this neuroprotection. Because we have shown previously that an amyloid beta peptide-mediated potentiation of calcium channel currents may contribute to this cytosolic calcium overload, the present study examined the effects of a secreted beta-amyloid precursor protein on the calcium channel response to amyloid beta peptide. When compared with untreated cultured rat hippocampal neurons, cells that underwent a 24 h preincubation with beta-amyloid precursor protein 751 displayed decreases in the relative size of the calcium channel response to amyloid beta peptide. A membrane-permeable analog of cyclic GMP, a second messenger believed to be involved in the calcium regulation process mediated by beta-amyloid precursor proteins, also attenuated the modulatory calcium channel response. Co-application of beta-amyloid precursor protein 751 with amyloid beta peptide did not alter calcium channel response to amyloid beta peptide. Taken together, these findings suggest that secreted beta-amyloid precursor proteins can suppress a calcium channel response to amyloid beta peptide that is potentially injurious to the cell, and as such, may define a neuroprotective mechanism that is specific for amyloid beta toxicity.

Amyloid beta-Peptides↗

Influence of lung volume on pulmonary microvascular pressure-volume characteristics.

The pressure-volume (P-V) characteristics of the lung microcirculation are important determinants of the pattern of pulmonary perfusion and of red and white cell transit times. Using diffuse light scattering, we measured capillary P-V loops in seven excised perfused dog lobes at four lung volumes, from functional residual capacity (FRC) to total lung capacity (TLC), over a wide range of vascular transmural pressures (Ptm). At Ptm 5 cmH(2)O, specific compliance of the microvasculature was 8.6%/cmH(2)O near FRC, decreasing to 2.7%/cmH(2)O as lung volume increased to TLC. At low lung volumes, the vasculature showed signs of strain stiffening (specific compliance fell as Ptm rose), but stiffening decreased as lung volume increased and was essentially absent at TLC. The P-V loops were smooth without sharp transitions, consistent with vascular distension as the primary mode of changes in vascular volume with changes in Ptm. Hysteresis was small (0.013) at all lung volumes, suggesting that, although surface tension may set basal capillary shape, it does not strongly affect capillary compliance.

Animals↗

Mechanical properties of cultured human airway smooth muscle cells from 0.05 to 0.4 Hz.

We investigated the rheological properties of living human airway smooth muscle cells in culture and monitored the changes in rheological properties induced by exogenous stimuli. We oscillated small magnetic microbeads bound specifically to integrin receptors and computed the storage modulus (G') and loss modulus (G") from the applied torque and the resulting rotational motion of the beads as determined from their remanent magnetic field. Under baseline conditions, G' increased weakly with frequency, whereas G" was independent of the frequency. The cell was predominantly elastic, with the ratio of G" to G' (defined as eta) being approximately 0. 35 at all frequencies. G' and G" increased together after contractile activation and decreased together after deactivation, whereas eta remained unaltered in each case. Thus elastic and dissipative stresses were coupled during changes in contractile activation. G' and G" decreased with disruption of the actin fibers by cytochalasin D, but eta increased. These results imply that the mechanisms for frictional energy loss and elastic energy storage in the living cell are coupled and reside within the cytoskeleton.

Cell Movement↗

Vehicle emission unit risk factors for transportation risk assessments.

When the transportation risk posed by shipments of hazardous chemical and radioactive materials is being assessed, it is necessary to evaluate the risks associated with both vehicle emissions and cargo-related risks. Diesel exhaust and fugitive dust emissions from vehicles transporting hazardous shipments lead to increased air pollution, which increases the risk of latent fatalities in the affected population along the transport route. The estimated risk from these vehicle-related sources can often be as large or larger than the estimated risk associated with the material being transported. In this paper, data from the U.S. Environmental Protection Agency's Motor Vehicle-Related Air Toxics Study are first used to develop latent cancer fatality estimates per kilometer of travel in rural and urban areas for all diesel truck classes. These unit risk factors are based on studies investigating the carcinogenic nature of diesel exhaust. With the same methodology, the current per-kilometer latent fatality risk factor used in transportation risk assessments for heavy diesel trucks in urban areas is revised and the analysis expanded to provide risk factors for rural areas and all diesel truck classes. These latter fatality estimates may include, but are not limited to, cancer fatalities and are based primarily on the most recent epidemiological data available on mortality rates associated with ambient air PM-10 concentrations.

Hazardous Substances↗