Inspiratory aerodynamic valving in goose lungs depends on gas density and velocity.

The non-reversing gas flow pattern in the avian lung has been attributed to 'aerodynamic valves'. A fundamental property of all aerodynamic valves is their dependence on inertial forces in the gas stream: sufficient reduction of inertial forces will cause aerodynamic valves to fail. If valving in the avian lung is aerodynamic, it should fail when gas stream momentum is reduced. We tested the dependence of the inspiratory valves in the goose lung on gas density and gas flow velocity. A bolus of tracer gas was placed in the tracheal cannula during an end-expiratory pause. Tracer gas appearance in a cranial air sac during the following inspiration and pause was used to deduce failure of the 'inspiratory valve' in cyclically ventilated geese. Little or no tracer entered the sac under control conditions, which approximated resting breathing, indicating highly effective valving. Lower flow rate or lower gas density caused increased tracer appearance, indicating valve failure. These results demonstrate the importance of gas inertial forces to normal valve function, and are direct evidence for the aerodynamic nature of the avian inspiratory valve.

Animals↗

Magnetic particle motions within living cells. Physical theory and techniques.

Body tissues are not ferromagnetic, but ferromagnetic particles can be present as contaminants or as probes in the lungs and in other organs. The magnetic domains of these particles can be aligned by momentary application of an external magnetic field; the magnitude and time course of the resultant remanent field depend on the quantity of magnetic material and the degree of particle motion. The interpretation of magnetometric data requires an understanding of particle magnetization, agglomeration, random motion, and both rotation and translation in response to magnetic fields. We present physical principles relevant to magnetometry and suggest models for intracellular particle motion driven by thermal, elastic, or cellular forces. The design principles of instrumentation for magnetizing intracellular particles and for detecting weak remanent magnetic fields are described. Such magnetic measurements can be used for noninvasive studies of particle clearance from the body or of particle motion within body tissues and cells. Assumptions inherent to this experimental approach and possible sources of artifact are considered and evaluated.

Animals↗

Dimensional analysis does not determine a mass exponent for metabolic scaling.

In several recent article, Heusner used dimensional reasoning to derive important biological conclusions regarding the scaling of metabolism with body mass [Respir. Physiol. 48: 13-25, 1982; J. Appl. Physiol. 54: 867-873, 1983; Am. J. Physiol. 246 (Regulatory Integrative Comp. Physiol. 15): R839-R845, 1984]. We demonstrate errors in the derivation and show that dimensional analysis, correctly applied, not only fails to determine the mass scaling exponent but also fails to constrain the relationship to a power law at all.

Body Constitution↗

Longitudinal elastic wave propagation in pulmonary parenchyma.

Consideration of the lung as an elastic continuum led us to investigate the possible propagation of elastic waves. Here the relevant stiffness and density are given by the Lamé constants and density of the parenchyma. To test this hypothesis, we measured propagation velocities (c) in dog lobes by recording transit times of a velocity impulse on one side of the lobe and the subsequent arrival on the other side. We compared our measured values of c with elastic longitudinal wave velocities (c long) predicted by values of elastic moduli given by Lai-Fook et al. (J. Appl. Physiol. 40: 508-513, 1976) as a function of translobar pressure (PL) and our measured densities. Good agreement was found between c and c long. Typical values of c ranged from 250-1,500 cm/s as PL ranged from 2-20 cmH2O. No systematic difference in the c-c long relation was found between inflation and deflation, suggesting that the elastic moduli of lungs are essentially a function of pressure. No significant effect was observed by changing the physical properties of the gas within the lobe [air vs. He vs. sulfur hexafluoride (SF6)], suggesting that indeed we were observing waves associated with the coupling of parenchymal density to parenchymal stiffness.

Animals↗

Ventilatory effectiveness of high-frequency oscillation applied to the body surface.

To determine the ventilatory effectiveness of high-frequency oscillation (HFO) at different sites on the body surface, we applied HFO separately to the abdomen, the rib cage, or the whole body in eight anesthetized and paralyzed dogs. Test frequencies were 5, 7, 9, and 11 Hz with tidal volume kept constant at 2.5 ml/kg. During HFO application to the abdomen, we observed significantly higher arterial O2 partial pressure (P less than 0.05) at 5, 7, and 9 Hz and lower arterial CO2 partial pressure (P less than 0.05) at 7, 9, and 11 Hz than with rib cage or whole-body HFO. There was no significant difference in blood gases between rib cage and whole-body HFO. Thus, using blood gases as an index of ventilatory effectiveness, the present study showed that HFO applied at the abdomen was the most effective of the three kinds of body surface HFO. In comparison to rib cage or whole-body application, abdominal HFO was accompanied by substantial paradoxical movement of the diaphragm and rib cage. The associated lung distortion may result in pendelluft, which in turn may be the mechanism for increased ventilatory effectiveness with abdominal application of HFO.

Abdomen↗

Relation of mouth flow to body surface flow during forced oscillation at the chest.

We have investigated the body surface flow/mouth flow transfer function (magnitude ratio and phase difference) in seven healthy male subjects driven at the chest from 4 to 30 Hz. The measurements were performed with a specially designed plethysmograph and analyzer. The subjects were driven with a mechanical oscillator placed on the sternum. After differences in gas temperature and humidity were taken into account, the data were in agreement up to 15 Hz with a simple second-order model including an airway compartment, with a resistance and an inertance, and a shunt compliance representing alveolar gas. At larger frequencies, closer inspection revealed that a third-order model was optimal. We interpret these results as indicating a compartmentalization of gas compliance within the thorax, communicating via a resistive element. Airway inertance did not seem to be distributed.

Humans↗

Quality of life for 'new' long-stay psychiatric in-patients. The effects of moving to a hostel.

We observed 15 'new' long-stay patients in wards in a District General Hospital Unit and a mental hospital, and again when they had lived for a year in a new hospital-hostel. There were significant changes in time spent in the community, social interaction, activity and abnormal behaviour. Residents believed they had more freedom and none wanted to return to wards. Six patients remained on wards. They showed no comparable changes and all wanted to live elsewhere.

Adult↗

Effects of increasing the frequency of low doses of gonadotropin-releasing hormone (GnRH) on gonadotropin secretion in GnRH-deficient men.

The effects of increasing the frequency of pulsatile GnRH administration on LH and FSH responsiveness were studied in five GnRH-deficient men who had achieved normal sex steroid levels during prior long term GnRH replacement. Intravenous doses of GnRH were employed that had previously been demonstrated to produce LH and FSH levels in each subject similar to those in normal men. Both acute and chronic changes in pituitary responses were studied after progressive increases in GnRH frequency (from every 120 to 60 min, from 60 to 30 min, and from 30 to 15 min) during three 12-h admissions, each separated by 7 days. During the two intervals between the studies GnRH frequency was 60 and 30 min, respectively. Pituitary responses were characterized by determining the mean serum LH and FSH levels, LH pulse amplitudes, and mean LH and FSH levels which were normalized for the frequency of GnRH administration (nLH and nFSH). As the frequency of GnRH stimulation was increased acutely, mean serum LH levels rose progressively, in contrast to both LH pulse amplitude and nLH levels which decreased, while serum testosterone (T) concentrations remained constant. No further evidence of gonadotroph desensitization occurred after chronic GnRH administration at either 60- or 30-min intervals. At higher frequencies of GnRH stimulation, discrete pulses of LH were not always apparent after injections of GnRH, and in two men, marked destabilization of the gonadotroph responses occurred. Even without detectable LH pulses, serum T levels did not decline during administration of GnRH at intervals as rapid as 15 min. In contrast, there was no change in mean FSH concentrations, although nFSH values decreased progressively as the GnRH frequency was increased. nFSH levels fell to a greater degree than nLH after each increase in GnRH frequency. Thus, pituitary gonadotroph responsiveness to a fixed dose of GnRH decreased as the frequency of GnRH stimulation increased. FSH responsiveness decreased to a greater degree than did LH. Gonadotropin secretory responses are destabilized at higher frequencies of GnRH administration. Pulsatile LH stimulation of the testes does not appear necessary to maintain T secretion.

Adult↗

Interpulse interval sequence of LH in normal men essentially constitutes a renewal process.

Luteinizing hormone (LH) is released from the anterior pituitary gland in an episodic pattern driven by pulses of gonadotropin-releasing hormone (GnRH) from the hypothalamus. Autocorrelation analysis of the sequence of interpulse intervals of LH secretion in normal men supports the hypothesis that the underlying mechanism driving LH secretion is a renewal process. That is, whatever "memory" the GnRH pulse generator (i.e., the hypothalamus or its antecedent neural drive) may have, it does not go back in time further than the preceding secretory pulse. Thus the hypothalamic timer starts over again each time there is a GnRH secretory episode.

Feedback↗

Radial and longitudinal compartmental analysis of gas transport during high-frequency ventilation.

A model of gas exchange by low-tidal-volume (VT), high-frequency ventilation (HFV) is presented, based on the physical principles of dispersion. These are the nonuniformity of the velocity profile and the nonreversible mixing of fluid components in a diffusive manner. A numerical method was used to incorporate these principles into a quantitative model. The airways of a symmetrically bifurcating bronchial-tree model were partitioned in the radial direction into two concentric layers representing the kinematic dispersion by nonuniformity of the velocity profile. Mixing between the layers was invoked in proportion to the diffusivity and local dimensions. The effects of frequency (f), VT, shape of the velocity profile, and bronchial-model configuration were tested in the model, with favorable comparison to available experimental data. The model predicts that for a frequency-dependent velocity profile, the rate of tracer exchange is proportional to the square root of f and to the square of VT-V0, where V0 is a constant small volume under which gas exchange was nil. Intracycle asymmetric mixing is predicted to have a stronger effect on gas exchange than asymmetric velocity profile. Gas exchange when turbulent-flow regime is assumed is predicted to be less for the higher VT values than with laminar flow and with mixing by molecular diffusivity. This model was found to be didactic, flexible, and capable of modeling combinations of factors affecting either one of the two fundamental processes of dispersion.

Animals↗

Bio- and immunoactive luteinizing hormone responses to low doses of gonadotropin-releasing hormone (GnRH): dose-response curves in GnRH-deficient men.

Previous investigations of the effects of GnRH on pituitary LH responses in normal men required pharmacological doses of GnRH to avoid the confounding effects of endogenous GnRH secretion and employed nonphysiological dose intervals. To examine the role of GnRH in determining both the qualitative and quantitative nature of physiological LH responses, we studied five GnRH-deficient men in whom pituitary and gonadal function had been normalized with GnRH replacement. Both bio- and immunoactive LH responses were evaluated in these men after a wide range of GnRH doses (7.5-250 ng/kg) administered at a physiological frequency (every 2 h), while gonadal steroid levels were within the normal adult male range. In addition, the amplitude and contour of the immunoactive LH pulses were compared to those of 15 normal men to assure that these experiments achieved physiological pituitary responses. The relationship between bio- and immunoactive LH was compared between patients, between doses as the amount of GnRH was increased, and within pulses of LH. As the dose of GnRH was increased, both bio- and immunoactive LH responses increased in a log-linear fashion when assessed by both amplitude (r = 0.96 for bioactive LH and r = 0.98 for immunoactive LH) and area under the curve (r = 0.99 for bioactive LH and r = 0.97 for immunoactive LH). GnRH doses of 7.5 and 25 ng/kg produced LH responses with amplitudes similar to those in normal men. The relationship between bio- and immunoactive LH between patients and between differing doses of GnRH was analyzed by comparing the slopes of lines fit to individual bioactive vs. immunoactive LH plots after each dose of GnRH in each patient. There was a marked variation in the relationship of bio- to immunoactive LH between patients (P less than 0.005). No change was found in the biopotency of LH as the dose of GnRH was increased (P less than 0.10). Finally, no variation of the bioactivity of LH was evident within individual pulses. We conclude that a log-linear relationship exists between doses of GnRH that produce physiological LH pulses and both bio- and immunoactive LH responses; the bioactivity of secreted LH varies markedly between patients; the relative bioactivity of LH in an individual does not change as the dose of GnRH is increased; and no change in bioactivity of LH responses was demonstrated within pulses of LH.

Adolescent↗

Poissons' ratio of lung parenchyma and parenchymal interaction with bronchi.

A simple theory of lung elasticity and its interaction with bronchi was developed which led to the specific results. The experimental procedure for establishing these results used lobar bronchi from excised dog lungs, following Takishima, et al. ((1975) J. Appl. Physiol., 38: 875-881). First, we found a semi-direct technique for measuring Poisson's ratio (sigma) of lung parenchyma and the effect of lung parenchyma on bronchi (interdependence). Sigma was measured at 0.424 +/- 0.045; no correlation was observed between sigma and the elastic recoil pressure of the lung (PL). The interdependence increased with a corresponding increase in PL and reduced bronchial volume. Second, we predict that a relationship exists between the specific compliances of intact and excised bronchi, and the specific compliance of the surrounding parenchyma. We suggest that the parenchyma is more important than the bronchus itself in determining the specific compliance of the intact bronchi.

Animals↗

Perfusion dehydration fixes elastin and preserves lung air-space dimensions.

We sought a technique to preserve lung tissue for micrography with air-space dimensions unchanged from the fresh state. In our hands, conventional techniques were problematical. Aware of the possibility that distortion might be caused by inadequate mechanical fixation of elastin, we dehydrated the still-inflated lung by intravascular perfusion with graded ethanols. Canine and rabbit lungs so prepared had straighter alveolar septa, greater air-space dimensions, and an improved correlation with light-scattering measurements. Bovine ligamentum nuchae (mostly elastin) was only partially fixed by glutaraldehyde or osmium tetroxide but was effectively stiffened by dehydration. We conclude that perfusion dehydration aids in the faithful preservation of parenchymal configuration, probably by mechanical fixation of elastin.

Animals↗

A theory of diffuse light scattering by lungs.

We present a theoretical treatment of backscattered light from the interior of a lung illuminated by a thin beam of light normally incident on the pleural surface. An approximate formula is developed describing how the backscattered intensity varies with distance from the point of light entry. This is shown to depend markedly on the optical mean free path and on the effective extinction coefficient. We attempt to relate the optical mean free path to the mean alveolar size. This relationship is found to depend primarily on septal reflection and refraction. Reflection is treated quantitatively. Refraction is much more difficult and may have to be approached empirically. We present here the rudiments of a technique with implications for the possibility of dynamic stereology.

Light↗

Light scattering by lungs correlates with stereological measurements.

The pattern of light backscattered by lung tissue should depend strongly on the size of air spaces and equivalently on the internal surface area of the lung. To verify and apply this, we shone a laser beam into excised lungs through the pleural surface and measured the backscattered light surrounding the beam with a focused photodetector. The intensity, I, fell off as a function of distance, r, from the point of entry of light. The configurations of I(r) curves corresponded closely to theory over a 3-decade range of I. I(r) changed systematically with lung volume. The optical mean free path, lambda, was calculated from I(r) curves in a series of canine lobes fixed immediately after optical scanning and was compared with stereological measurement of mean linear intercept, Lm, an index of alveolar size. At high lung volumes the relation of lambda to Lm was consistent with reflection by alveolar septa. At lower lung volumes there appeared to be, additionally, a substantial refractive component. This technique is independent of current stereological methods and has the advantages of being noninvasive, continuous, and potentially applicable to dynamic events in unfixed lungs.

Animals↗

Pressure-flow relationships of endotracheal tubes during high-frequency ventilation.

We studied the pressure-flow relationships of various endotracheal tubes (ETT) at frequencies (f) and tidal volumes (VT) in the range used for high-frequency ventilation (HFV) (f: 2-32 Hz, VT: 15-100 ml). Sinusoidal flows were applied to ETT inserted into a rigid bottle or into the tracheae of three anesthetized paralyzed dogs, while pressure fluctuations were measured both proximal and distal to the ETT. The pressure drops in the ETT were nonlinearly related to the peak flow rate and were VT dependent, suggesting that turbulent frictional head loss and convective acceleration were important. The pressure drops measured in vitro were found to be in good agreement with the predictions of a nonlinear oscillatory pressure-flow equation (derived herein), which incorporate the effects of turbulent frictional losses, convective acceleration, inertance, and compliance. The pressure drops measured in situ were 30-50% higher than with the corresponding f-VT combinations in vitro. Possible explanations of these differences are junctional losses at the tip of the ETT or the nonrigid character of the trachea.

Animals↗

Photographic measurement of pleural surface motion during lung oscillation.

The regional pleural surface expansion of an excised dog lung was measured during high-frequency ventilation (HFV) using synchronized stroboscopic photography to stop lung motion at 20 evenly spaced intervals over a respiratory cycle during ventilation at 1 Hz with a volume of 100 ml, 15 Hz with 100 ml, or 30 Hz with 50 ml. The lungs were also photographed during quasi-static deflation. The pleural surface was marked with ink dots to form 84 approximately square figures. The side lengths and areas of each of the 84 "squares" were measured for each frame of each photo sequence. At 1 Hz and during the quasi-static deflation the lung ventilated nearly synchronously, although minor nonuniformities were noted on both small and large length scales. At 15 and 30 Hz, the lung expanded asynchronously and nonuniformly, with a 78% increase in surface expansion per 100 ml of tracheal tidal volume, as frequency was increased from 1 to 30 Hz. These nonuniformities in expansion suggest marked interregional airflow and elastic wave propagation in the parenchyma during HFV.