[Implantable infusion devices. Experience of 360 cases].

Between january 1, 1983 and december 31, 1986, 360 implantable infusion devices were inserted for systemic chemotherapy. Most of the devices were Port A Cath systems. The main complications observed were thrombosis (18 cases, 5%) and infection (8 cases, 2.2%). Since one year the catheters are being introduced by subcutaneous puncture of the subclavian vein, the chambers being placed in a small lateral subclavicular cavity. Intra-operative radiography is necessary to minimize the risk of malposition and thrombosis. These systems, relayed by external pumps, enable chemotherapeutic regimens to be administered sequentially over a 24-hour period.

Humans↗

[Extensive ulceronecrotizing anorectitis caused by abuse of analgesic suppositories].

Usually considered as totally unoffensive, antalgic suppositories can, under certain conditions, lead to extensive anorectal injury with anatomic, functional and legal implications which we evaluated on the basis of two cases and a review of the literature. Clinicians, surgeons, pathologists and pharmaceutical firms should be aware of these pathophysiological events. Consumer information is required to reduce the risk of self-medication. There are characteristic psychologic situations and "dose-dependent" toxic effects which, as the saying goes "errare humanum est, perseverare diabolicum". Careful use of scientific knowledge and wise decisions by both experts and judges are required to avoid misinterpreting the pathogenesis of this particular anatomoclinical entity.

Analgesics↗