PubMed Health⌕ Search

Biomedical subjects

J P Culver

Publications and source records attributed to J P Culver.

8 recordsLinked to original sources

Can the cerebral metabolic rate of oxygen be estimated with near-infrared spectroscopy?

We have measured the changes in oxy-haemoglobin and deoxy-haemoglobin in the adult human brain during a brief finger tapping exercise using near-infrared spectroscopy (NIRS). The cerebral metabolic rate of oxygen (CMRO2) can be estimated from these NIRS data provided certain model assumptions. The change in CMRO2 is related to changes in the total haemoglobin concentration, deoxy-haemoglobin concentration and blood flow. As NIRS does not provide a measure of dynamic changes in blood flow during brain activation, we relied on a Windkessel model that relates dynamic blood volume and flow changes, which has been used previously for estimating CMRO2 from functional magnetic resonance imaging (fMRI) data. Because of the partial volume effect we are unable to quantify the absolute changes in the local brain haemoglobin concentrations with NIRS and thus are unable to obtain an estimate of the absolute CMRO2 change. An absolute estimate is also confounded by uncertainty in the flow-volume relationship. However, the ratio of the flow change to the CMRO2 change is relatively insensitive to these uncertainties. For the linger tapping task, we estimate a most probable flow-consumption ratio ranging from 1.5 to 3 in agreement with previous findings presented in the literature, although we cannot exclude the possibility that there is no CMRO2 change. The large range in the ratio arises from the large number of model parameters that must be estimated from the data. A more precise estimate of the flow-consumption ratio will require better estimates of the model parameters or flow information, as can be provided by combining NIRS with fMRI.

Adult↗

Three-dimensional diffuse optical tomography in the parallel plane transmission geometry: evaluation of a hybrid frequency domain/continuous wave clinical system for breast imaging.

Three-dimensional diffuse optical tomography (DOT) of breast requires large data sets for even modest resolution (1 cm). We present a hybrid DOT system that combines a limited number of frequency domain (FD) measurements with a large set of continuous wave (cw) measurements. The FD measurements are used to quantitatively determine tissue averaged absorption and scattering coefficients. The larger cw data sets (10(5) measurements) collected with a lens coupled CCD, permit 3D DOT reconstructions of a 1-liter tissue volume. To address the computational complexity of large data sets and 3D volumes we employ finite difference based reconstructions computed in parallel. Tissue phantom measurements evaluate imaging performance. The tests include the following: point spread function measures of resolution, characterization of the size and contrast of single objects, field of view measurements and spectral characterization of constituent concentrations. We also report in vivo measurements. Average tissue optical properties of a healthy breast are used to deduce oxy- and deoxy-hemoglobin concentrations. Differential imaging with a tumor simulating target adhered to the surface of a healthy breast evaluates the influence of physiologic fluctuations on image noise. This tomography system provides robust, quantitative, full 3D image reconstructions with the advantages of high data throughput, single detector-tissue coupling path, and large (1L) imaging domains. In addition, we find that point spread function measurements provide a useful and comprehensive representation of system performance.

Adult↗

Bulk optical properties of healthy female breast tissue.

We have measured the bulk optical properties of healthy female breast tissues in vivo in the parallel plate, transmission geometry. Fifty-two volunteers were measured. Blood volume and blood oxygen saturation were derived from the optical property data using a novel method that employed a priori spectral information to overcome limitations associated with simple homogeneous tissue models. The measurements provide an estimate of the variation of normal breast tissue optical properties in a fairly large population. The mean blood volume was 34 +/- 9 microM and the mean blood oxygen saturation was 68 +/- 8%. We also investigated the correlation of these optical properties with demographic factors such as body mass index (BMI) and age. We observed a weak correlation of blood volume and reduced scattering coefficient with BMI: correlation with age, however, was not evident within the statistical error of these experiments. The new information on healthy breast tissue provides insight about the potential contrasts available for diffuse optical tomography of breast tumours.

Adult↗

In vivo cerebrovascular measurement combining diffuse near-infrared absorption and correlation spectroscopies.

We combine two near-infrared diffuse optical techniques to study variations of blood flow, haemoglobin concentration, and blood oxygen saturation in the functioning rat brain. Diffuse correlation spectroscopy (or flowmetry) monitors changes in the cerebral blood flow, without the use of the principles of tracer clearance, by measuring the optical phase-shifts caused by moving blood cells. Near-infrared absorption spectroscopy concurrently measures tissue absorption at two wavelengths to determine haemoglobin concentration and blood oxygen saturation in this same tissue volume. This optical probe is non-invasive and was employed through the intact skull. The utility of the technique is demonstrated in vivo by measuring the temporal changes in the regional vascular dynamics of rat brain during hypercapnia. Temporal and spatial variations of cerebral blood flow, haemoglobin concentration and blood oxygen saturation during hypercapnia are compared with other measurements in the literature, and a quantitative analysis demonstrating the self-consistency of our combined observations of vascular response is presented.

Animals↗

Recovery of optical parameters in multiple-layered diffusive media: theory and experiments.

Diffuse photon density waves have lately been used both to characterize diffusive media and to locate and characterize hidden objects, such as tumors, in soft tissue. In practice, most biological media of medical interest consist of various layers with different optical properties, such as the fat layer in the breast or the different layers present in the skin. Also, most experimental setups consist of a multilayered system, where the medium to be characterized (i.e., the patient's organ) is usually bounded by optically diffusive plates. Incorrect modeling of interfaces may induce errors comparable to the weak signals obtained from tumors embedded deep in highly heterogeneous tissue and lead to significant reconstruction artifacts. To provide a means to analyze the data acquired in these configurations, the basic expressions for the reflection and transmission coefficients for diffusive-diffusive and diffusive-nondiffusive interfaces are presented. A comparison is made between a diffusive slab and an ordinary dielectric slab, thus establishing the limiting distance between the two interfaces of the slab for multiple reflections between them to be considered important. A rigorous formulation for multiple-layered (M-layered) diffusive media is put forward, and a method for solving any M-layered medium is shown. The theory presented is used to characterize a two-layered medium from transmission measurements, showing that the coefficients of scattering, mu'(s) , and absorption, mu(a) , are retrieved with great accuracy. Finally, we demonstrate the simultaneous retrieval of both mu;(s) and mu(a).

Diffusion↗

Near-field diffraction tomography with diffuse photon density waves.

An angular spectrum algorithm is presented for fast, near-field diffraction tomographic imaging with diffuse photon density waves in highly scattering media. A general relation in K space is derived that connects the spatial variations of the optical properties of heterogeneities to the spatial spectra of the measured scattered diffuse photon density waves. The theory is verified experimentally for situations when boundary effects can be neglected. We further describe how to reconstruct absorption and scattering properties simultaneously, and how to incorporate boundary conditions into this angular spectrum algorithm for a turbid medium of finite size (e.g., the slab medium). Limitations and potential improvements of the near-field diffraction tomography are also discussed.

Algorithms↗