Anterior vertebral screw strain with and without solid interspace support.

STUDY DESIGN: This in vitro biomechanical study examines segmental anterior vertebral screw strain and solid rod construct stiffness with and without the addition of multilevel, threaded cortical bone dowels in a bovine model. OBJECTIVE: To determine whether strain at the bone-screw interface is higher at the end levels during physiologic range loading, and whether solid interspace support decreases segmental strain on the implant. SUMMARY OF BACKGROUND DATA: Anterior instrumentation provides greater correction and preserves distal motion segments. However, nonunion and implant failure are observed more frequently than with posterior segmental instrumentation, and when observed, loss of fixation occurs at the end levels. METHODS: Eight calf spines underwent mechanical testing in the following sequence: 1) intact condition, 2) anterior release with anterior solid rod and bicortical rib grafts, and 3) anterior release with anterior solid rod and threaded cortical bone dowels (L2-L5). Instrumented vertebral screws were used to assess strain within the vertebral body by the near cortex, whereas an anterior extensometer spanning the instrumented segments was used to measure segmental displacements to calculate construct stiffness. The protocol included axial compression (-400 N), right lateral bending (4 Nm (Newton-meter), away from the implant), and left lateral bending (4 Nm, toward the implant). Statistical analysis included a one-way analysis of variance and a Student-Newman-Keuls post hoc test. A pilot study was performed using four additional specimens loaded for 4000 cycles to investigate macroscopic loosening after fatigue loading. RESULTS: In lateral bending toward the implant, the strain was higher at both end levels, with no differences between the rib and dowel reconstructions. The stiffness values were greater than the intact values for both groups. In lateral bending away from the implant, the strain also was higher at both end screws, and the dowel group had less strain at these levels than the rib group. Both groups were stiffer than the intact condition, and the dowel group was stiffer than the rib group. Axial compressive strain also was higher at the end levels, but this difference did not reach statistical significance. The rib group did not reach intact stiffness values, whereas the dowel group was stiffer than the intact condition. The fatigue study showed gross loosening at one or both end levels in all cases. CONCLUSIONS: Higher strain was observed at the bone-screw interface in both end screws of an anterior solid rod construct during lateral bending, which correlates with the clinically observed failure location. This suggests that physiologic range loading may predispose to failure at the end levels. Disc space augmentation with solid implants increased construct stiffness in all three load paths and decreased strain at the end levels in lateral bending away from the implant. Future implant modifications should achieve better fixation at the end screws, and the current model provides a means to compare different strategies to decrease strain at these levels.

Animals↗

Results of brace treatment of scoliosis in Marfan syndrome.

STUDY DESIGN: Retrospective review of a defined Marfan population with traditional indications for bracing. OBJECTIVES: To determine the success rate of brace treatment in keeping curves from progressing by more than 5 degrees or exceeding 45 degrees. SUMMARY OF BACKGROUND DATA: Few studies exist regarding brace treatment of Marfan syndrome, and they include many patients with curves of more than 45 degrees, as well as some who are near maturity. All of the prior studies risk the possibility of some selection bias. METHODS: Patients were selected from support groups and several institutions. Inclusion criteria were: Definite diagnosis of Marfan syndrome, curve of 45 degrees or less, Risser sign 2, 1, or 0 at inception of bracing, recommended wear of 18 hours or more per day, and follow-up until maturity or surgery (minimum, 2 years). Success was defined as curve progression of 5 degrees or less and final curve remaining 45 degrees or less. Failure was a final curve of more than 45 degrees. Twenty-four patients met the criteria. There were 15 girls and 9 boys. Twenty-two patients wore a brace as recommended. Two additional patients were unable to tolerate it. RESULTS: Mean age at inception of bracing was 8.7 years (range, 4-12 years). There were 14 double major, 6 thoracic, and 4 thoracolumbar curves with a mean size of 29 degrees at the beginning of bracing. The stated wearing time averaged 21 hours per day. Five patients had significant pain over bony prominences. Although correction of the curve in brace was good (45%), only 4 of the patients had success, and in 20 of the 24 treatment was considered a failure. Mean progression was 6 degrees +/- 8 degrees per year, for a final mean curve of 49 degrees. Sixteen of the patients had, or were advised to have, surgical correction. The difference in age and degree of curvature were not statistically significant between the success and nonsuccess groups. CONCLUSIONS: The success rate for brace treatment of Marfan scoliosis is 17%, which is lower than that reported for idiopathic scoliosis. Possible reasons include increased progressive forces, altered transmission of corrective pressure to the spine, and younger age at inception of bracing. Because there was no control group, it is unknown whether bracing slowed curve progression. Physicians should understand that most patients with Marfan syndrome who have a curve of more than 25 degrees and a Risser sign of 2 or less will reach the surgical range, even with brace treatment.

Braces↗

Prevention of positional brachial plexopathy during surgical correction of scoliosis.

Continuous intraoperative monitoring of spinal cord function using somatosensory evoked potentials (SSEP) has gained nearly universal acceptance as a reliable and sensitive method for detecting and possibly preventing neurologic injury during surgical correction of spinal deformities. In several reports, spinal cord injury was identified successfully based on changes in SSEP response characteristics, specifically amplitude and latency. Less well documented and used, however, is monitoring of peripheral nerve function with SSEPs to identify and prevent the neurologic sequelae of prolonged prone positioning on a spinal frame. The authors describe a patient who underwent surgical removal of spinal instrumentation but was not monitored. A brachial plexopathy developed in this patient from pressure on the axilla exerted by a Relton-Hall positioning frame during spinal surgery. In addition, data are presented from 15 of 500 consecutive pediatric patients who underwent surgical correction of scoliosis between 1993 and 1997 with whom intermittent monitoring of ulnar nerve SSEPs was used successfully to identify impending brachial plexopathy, a complication of prone positioning. A statistically significant reduction in ulnar nerve SSEP amplitude was observed in 18 limbs of the 500 patients (3.6%) reviewed. Repositioning the arm(s) or shoulders resulted in nearly immediate improvement of SSEP amplitude, and all awoke without signs of brachial plexopathy. This complication can be avoided by monitoring SSEPs to ulnar nerve stimulation for patients placed in the prone position during spinal surgery.

Adult↗

Two primary osteosarcomas in a patient with Rothmund-Thomson syndrome.

Rothmund-Thomson syndrome is an autosomal recessive disorder characterized by poikilodermatous skin changes that develop in infancy. Associated manifestations include juvenile cataracts, sparse hair, short stature, skeletal defects, dystrophic nails and teeth, and hypogonadism. An increased incidence of malignancy, including osteosarcoma, has been reported in patients with Rothmund-Thomson syndrome. The molecular basis of the disorder is not known. This report describes a patient with Rothmund-Thomson syndrome in whom two primary osteosarcomas developed 12 years apart. The presentation, diagnosis, and treatment of osteosarcoma in this patient with Rothmund-Thomson syndrome are described. Cytogenetic and molecular analysis of peripheral blood and skin fibroblasts had low level mosaicism for trisomy of chromosomes 2 and 8. Although several patients have been described with mosaic trisomy 8 and i(2q) (mosaic isochromosome for the long arm of chromosome 2), the patient described here is the first to have mosaic trisomy for the entire chromosomes 2 and 8. The cytogenetic findings in this patient are consistent with an underlying defect in chromosomal stability.

Bone Neoplasms↗

Major pediatric hand trauma associated with fireworks.

OBJECTIVES: To characterize the injury pattern and economic impact of major pediatric hand trauma secondary to fireworks. DESIGN: Retrospective. SETTING: Pediatric Level I trauma center. INTERVENTION: N/A MAIN OUTCOME MEASUREMENTS: Fractures, amputations, soft tissue defects, length of hospitalization, number and type of procedures performed were obtained from charts, radiographs, and operative reports. Hospital charges were obtained from the billing office. PATIENTS/PARTICIPANTS: Records of patients with a diagnosis of fireworks-related injuries admitted over a period of ten years were reviewed. Twenty-two patients were identified to have sustained twenty-two hand injuries. The group consisted of nineteen boys and three girls, with an average age of 9.3 years (range, 4 to 17 years). RESULTS: There were thirty-one fractures, nineteen amputations, and one dislocation. The nineteen amputations occurred in nine hands. Local skin graft or flap coverage was required in six hands acutely, and delayed soft tissue procedures were performed on four hands. Four hands had digital neurovascular injuries; two required microsurgical repairs at the time of injury, and two were irreparable. Resource use included: average hospital stay of 4.3 days (range, 0 to 20), average number of trips to the operating room, 1.2 (range, 0 to 3), and average hospital charges of $11,582 (range, $1,035 to $39,489). CONCLUSIONS: This study illustrates the severity of pediatric hand injuries associated with fireworks and the significant burden placed on medical resources in treating these injuries. Efforts toward public education and legislative reforms may help to prevent these unnecessary injuries.

Adolescent↗

Growth disturbances after distal tibial physeal fractures.

Twenty-four patients with distal tibial growth disturbance were reviewed. Disturbances were classified as physeal bar (prior to deformity), angular, linear or combined deformities. Treatment consisted of osteotomy in fourteen, epiphyseodesis in seven, excision of bony bar in two, and observation in one patient. Follow up was an average 36.6 months (range 4-129 months) after treatment of growth disturbance. The age at time of injury was 10.4 years of age average (range 3-15 years). There were 12 SH2, 2 SH3, 7 SH4, and 3 SH5 distal tibial physeal fractures. Thirteen of 15 fractures considered high energy and only 1 of 9 fractures considered low energy resulted in angular deformity. Angular and linear deformities presented an average 46 months (range 12-120 months) and physeal bars at an average 14 months (range 6-25 months) after injury. Patients with a delay in presentation of growth disturbance greater than 24 months had angular deformities in 92% compared with 33% in children presenting less than or at 24 months. Treatment based on type of deformity, age at time of injury, and growth remaining was considered successful in 83%. Patients with angular or linear deformities were more likely to present late, have high energy injuries, be male patients and have Salter-Harris types IV and V. Early diagnosis and treatment of growth disturbance can prevent severe deformity.

Adolescent↗

Augmentation of an anterior solid rod construct with threaded cortical bone dowels. A biomechanical study.

STUDY DESIGN: This static, nondestructive, in vitro biomechanical study examines anterior solid rod construct stiffness following the addition of multilevel, threaded cortical bone dowels in a bovine model. A comparison is made with a clinically relevant posterior construct with and without an anterior release. OBJECTIVES: To determine if the addition of solid, multilevel disc space implants will increase construct rigidity, while maintaining or enhancing anterior column length. SUMMARY OF BACKGROUND DATA: Anterior instrumentation for thoracolumbar and lumbar scoliosis has achieved greater correction and preserved distal motion segments; however, kyphosis over the instrumented segments and nonunion have been observed more frequently than with posterior segmental spinal instrumentation. METHOD: Fifteen calf spines underwent mechanical testing. Group A (n = 7) included anterior constructs: 1) intact, 2) anterior release/rod/rib graft (L2-L5), and 3) anterior release/rod/dowels (L2-L5). Group B (n = 8) included posterior constructs: 1) intact, 2) posterior rod without anterior release (T13-L5), 3) posterior rod (T13-L5)/anterior release/rib graft (L2-L5). The protocol included axial compression (-600 N), axial rotation (+7 Nm), flexion/extension (+7.5 Nm), and lateral bending (+7.5 Nm). An anterior extensometer measured segmental displacements to calculate construct stiffness. Lateral radiographs evaluated alignment for the anterior constructs. Statistical analysis involved a one way analysis of variance (ANOVA) and a Student-Newman-Keuls post hoc test. RESULTS: All reconstructions restored stiffness to intact values with the exception of the dowels alone in axial rotation. The rod/dowel construct was stiffer than all other groups in axial compression, flexion/extension, and lateral bending, with the exception of the posterior rod without discectomy, which was superior in flexion and statistically similar in extension, lateral bending, and axial rotation. The anterior construct with rib graft was equivalent to the posterior construct with rib graft in all modes of testing. The dowels created greater lordosis than the bicortical rib grafts. CONCLUSIONS: Disc space augmentation increased stiffness except in axial rotation, in which values were restored to the intact level. Stiffness was superior to a clinically relevant posterior instrumentation comparison group following anterior release, and was equivalent to a posterior construct without anterior release except in anterior flexion. In addition, the implants enhanced lordosis. Increased rigidity should improve rates of arthrodesis, while maintenance of sagittal alignment may prevent pathologic compensatory curves in adjacent spinal segments. Further research is required to determine the optimal method of achieving structural interspace support.

Animals↗

A comparison of various angles of halo pin insertion in an immature skull model.

STUDY DESIGN: A basic science biomechanical study involving an animal model. OBJECTIVES: To evaluate the effect of varying angles of halo pin insertion on the force generated at the pin-bone interface, and thereby the stability of the halo pin-bone interaction during insertion. BACKGROUND DATA: Because of variations in the shape and size of the pediatric skull, halo pins often are inserted at various angles rather than perpendicular to the skull. Concern exists that the high complication rate associated with pediatric halo use may result in part from less than ideal structural properties at the halo pin-bone interface. METHODS: The authors used a fetal calf skull model to simulate the thickness and structural properties of the pediatric skull. Halo pins were inserted at angles of 0 degree (perpendicular), 10 degrees, 15 degrees, and 30 degrees into skull segments via a halo ring. Load generated at the pin-bone interface was measured using a modified mechanical testing device. Twenty trials were conducted per angle, with the endpoint being specimen failure, pin penetration, or maximum load. RESULTS: Mean maximum loads per unit thickness were 82.15 +/- 7.54 N/mm at 0 degree, 68.80 +/- 4.79 N/mm at 10 degrees, 51.49 +/- 5.08 N/mm at 15 degrees, and 42.38 +/- 3.51 N/mm at 30 degrees, There was a significant difference between perpendicular insertion (0 degree) and 15 degrees angles of insertion. There was also a significant difference between the 10 degrees and 30 degrees angles of insertion. CONCLUSIONS: Perpendicular halo pin insertion in an immature skull model was shown to result in increased load at the pin-bone interface. This improved structural behavior may help to reduce the incidence of complications of halo application in children.

Animals↗

Surgical management of calcaneal unicameral bone cysts.

Unicameral bone cysts are not seen commonly in the calcaneus. Little is known about the etiology and natural history of these lesions. Calcaneal cysts often are symptomatic, although some of these lesions are detected as incidental findings. Treatment has been advocated based on the fear of pathologic fracture and collapse. Several published series have been divided in their favor for either open treatment or injection management. These series are small, and the optimal treatment is still in question. The current study compared the efficacy of methylprednisolone acetate injection treatment with curettage and bone grafting in the treatment of unicameral bone cysts of the calcaneus. All patients treated for unicameral bone cysts of the calcaneus during the past 7 years at two institutions were reviewed. Eleven patients met inclusion criteria. All diagnoses were confirmed radiographically or histologically. Demographic information, presenting complaints, diagnostic imaging, treatment modalities, and outcome were analyzed. Long term radiographic and subjective followup was obtained. Eighteen surgical procedures were performed on 11 patients with 12 cysts. Nine injections performed on six patients failed to show healing of the cyst. Nine cysts treated with curettage and bone grafting showed cyst healing. At mean followup of 28 months (range, 12-77 months), all 11 patients had no symptoms; there were no recurrences of the cyst in the nine patients who underwent bone grafting and persistence of the cyst in the two patients who underwent injection therapy. This review reports one of the largest series of cysts in this location. The results indicate that steroid injection treatment, although useful in other locations, may not be the best option for the management of unicameral bone cysts in the calcaneus. Curettage and bone grafting yielded uniformly good results.

Adolescent↗

Diagnosing aneurysmal and unicameral bone cysts with magnetic resonance imaging.

The differential between aneurysmal bone cysts and unicameral bone cysts usually is clear clinically and radiographically. Occasionally there are cases in which the diagnosis is not clear. Because natural history and treatment are different, the ability to distinguish between these two entities before surgery is important. The authors reviewed, in a blinded fashion, the preoperative magnetic resonance images to investigate criteria that could be used to differentiate between the two lesions. All patients had operative or pathologic confirmation of an aneurysmal bone cyst or unicameral bone cyst. The authors analyzed the preoperative magnetic resonance images of 14 patients with diagnostically difficult bone cysts (eight children with unicameral bone cysts and six children with aneurysmal bone cysts) and correlated these findings with diagnosis after biopsy or cyst aspiration and contrast injection. The presence of a double density fluid level within the lesion strongly indicated that the lesion was an aneurysmal bone cyst, rather than a unicameral bone cyst. Other criteria that suggested the lesion was an aneurysmal bone cyst were the presence of septations within the lesion and signal characteristics of low intensity on T1 images and high intensity on T2 images. The authors identified a way of helping to differentiate between aneurysmal bone cysts and unicameral bone cysts on magnetic resonance images. Double density fluid level, septation, and low signal on T1 images and high signal on T2 images strongly suggest the bone cyst in question is an aneurysmal bone cyst, rather than a unicameral bone cyst. This may be helpful before surgery for the child who has a cystic lesion for which radiographic features do not allow a clear differentiation of unicameral bone cyst from aneurysmal bone cyst.

Adolescent↗

A comparative evaluation of halo pin designs in an immature skull model.

To design an improved halo pin for use in pediatric patients, three commonly used halo pins were evaluated with a mechanical testing apparatus and segments of prepared fetal calf skull. The pins were driven through the bone segments while the load at the bone-pin interface was measured. New pins were designed with respect to pin tip and flange width and similarly compared. Mean maximum loads to penetration, normalized for bone segment thickness, were 55.6 N/mm for the PMT Corporation pin, 61.5 N/mm for the Bremer pin, and 73.6 N/mm for the Ace pin. Four new, short tipped pins were designed and compared with the Ace pin, and there was no significant difference. Finally, four new pins were designed with varying flange widths. Mean maximum loads, normalized for bone segment thickness, were 68.9 N/mm for the 4.2 mm flange, 72.2 N/mm for the 4.7 mm flange, 92.9 N/mm for the 5.2 mm flange, and 96.4 N/mm for the 5.7 mm flange. The findings of this investigation are clinically important because they may help to explain the variability in the complication rates seen with the use of different halo systems in children. The three halo pins currently on the market have different pin designs, including tip lengths and flange distances, which contribute to the difference in load to penetration for each pin. The new, wide flanged, short tipped halo pin design might decrease the complication rate of halo use in children by providing an improved capacity to resist penetration despite increased loads of application.