PubMed HealthSearch

Biomedical subjects

J P Glees

Publications and source records attributed to J P Glees.

4 recordsLinked to original sources

Effectiveness of topical steroids in the control of radiation dermatitis: a randomised trial using 1% hydrocortisone cream and 0.05% clobetasone butyrate (Eumovate).

Radiation dermatitis often presents as a problem for patients and radiotherapists during treatment. Topical corticosteroids have been shown to have an anti-inflammatory effect in the treatment of many skin diseases and are commonly prescribed during a course of radiation treatment. A comparison of two different steroid creams, 1% hydrocortisone cream and 0.05% clobetasone butyrate (Eumovate), in a double blind trial was carried out in 54 patients undergoing radiation therapy for breast cancer. 'The cream' was administered when patients reached a given dose of 2000 rad (or earlier if required) whether a skin reaction was present or not. The aim of the trial was to evaluate the general effectiveness of steroids in controlling radiation dermatitis and whether one type of cream was superior to the other. The majority of patients using either cream derived benefit in its soothing effect. There was, however, a significant difference in the intensity of reactions seen, patients using clobetasone butyrate developed more severe radiation reactions despite both groups having similar radiation doses. The possibility of two differing populations having different responses to radiation is discussed as is the 'breakthrough phenomenon' described in the literature. It is concluded that neither cream should be used as first choice in the control of radiation dermatitis.

Administration, Topical

Accuracy of grey-scale ultrasonography of liver and spleen in Hodgkin's disease and the other lymphomas compared with isotope scans.

Complementary techniques to laparotomy are required to monitor patients with lymphomas both before and after treatment. Our preliminary experience with grey-scale ultrasonography is presented. Fifty-two patients, themajority with Hodgkin's disease or other lymphomas, were examined with ultrasound equipment which was custom built. The essential difference between grey-scale equipment and conventional machines is the ability to display the internal consistency of soft organs. Of 20 spleens examined prior to splenectomy, the ultrasonic scan was considered suggestive of involvement in seven of nine that showed histological evidence of Hodgkin's disease. Threeof 11 histologically negative spleens were considered to be positive preoperatively and two of nine read as negative on the scan contained histological disease. Fifty livers were examined with ultrasound. Of seven patients with histological involvement four were read as positive and three as negative and six of 43 patients with no macroscopic or microscopic evidence of liver infiltration were also considered to have a positive ultrasonic scan. Ultrasonic scanning has proved useful for demonstrating enlarged lymph nodes in the porta hepatis, upper para-aortic lymph nodes and bulky mesenteric nodes. On the basis of these preliminary observations the potential value and application of the technique is discussed.

Adolescent