Three-dimensional path planning for virtual bronchoscopy.

Multidetector computed-tomography (MDCT) scanners provide large high-resolution three-dimensional (3-D) images of the chest. MDCT scanning, when used in tandem with bronchoscopy, provides a state-of-the-art approach for lung-cancer assessment. We have been building and validating a lung-cancer assessment system, which enables virtual-bronchoscopic 3-D MDCT image analysis and follow-on image-guided bronchoscopy. A suitable path planning method is needed, however, for using this system. We describe a rapid, robust method for computing a set of 3-D airway-tree paths from MDCT images. The method first defines the skeleton of a given segmented 3-D chest image and then performs a multistage refinement of the skeleton to arrive at a final tree structure. The tree consists of a series of paths and branch structural data, suitable for quantitative airway analysis and smooth virtual navigation. A comparison of the method to a previously devised path-planning approach, using a set of human MDCT images, illustrates the efficacy of the method. Results are also presented for human lung-cancer assessment and the guidance of bronchoscopy.

Algorithms↗

Videoendoscopic distortion correction and its application to virtual guidance of endoscopy.

Modern video-based endoscopes offer physicians a wide-angle field of view (FOV) for minimally invasive procedures. Unfortunately, inherent barrel distortion prevents accurate perception of range. This makes measurement and distance judgment difficult and causes difficulties in emerging applications, such as virtual guidance of endoscopic procedures. Such distortion also arises in other wide FOV camera circumstances. This paper presents a distortion-correction technique that can automatically calculate correction parameters, without precise knowledge of horizontal and vertical orientation. The method is applicable to any camera-distortion correction situation. Based on a least-squares estimation, our proposed algorithm considers line fits in both FOV directions and gives a globally consistent set of expansion coefficients and an optimal image center. The method is insensitive to the initial orientation of the endoscope and provides more exhaustive FOV correction than previously proposed algorithms. The distortion-correction procedure is demonstrated for endoscopic video images of a calibration test pattern, a rubber bronchial training device, and real human circumstances. The distortion correction is also shown as a necessary component of an image-guided virtual-endoscopy system that matches endoscope images to corresponding rendered three-dimensional computed tomography views.

Artifacts↗