PubMed HealthSearch

Biomedical subjects

J P Maurat

Publications and source records attributed to J P Maurat.

At least 19 recordsLinked to original sources

The double-balloon and Inoue techniques in percutaneous mitral valvuloplasty: comparative results in a series of 232 cases.

Immediate hemodynamic results of percutaneous mitral valvuloplasty were compared in two consecutive series of unselected patients from the same institution undergoing valvuloplasty with the double-balloon (161 patients) or the Inoue balloon (71 patients) technique. Before valvuloplasty, the patient series were comparable with regard to average age, gender repartition and most clinical, electrocardiographic, X-ray and hemodynamic variables. Poor anatomic forms of mitral stenosis were equally distributed in both series (41% vs. 45%, p = NS). The magnitude of mitral valve area increase and of mean mitral gradient decrease during percutaneous mitral valvuloplasty did not differ significantly in the Inoue balloon and double-balloon series (mean +/- SEM 1.1 +/- 0.2 to 1.95 +/- 0.5 and 1.0 +/- 0.2 to 1.97 +/- 0.5 cm2, respectively, for mitral valve area and 12 +/- 3 to 5 +/- 2 and 13 +/- 4 to 5 +/- 2 mm Hg, respectively, for mean mitral gradient). Four cases of 3+ mitral regurgitation occurred in the Inoue balloon series and 7 in the double-balloon series (p = NS). A good immediate result--defined as mitral valve area greater than or equal to 1.5 cm2 with greater than or equal to 25% in mitral valve area gain and mitral regurgitation less than 2+ at the end of the procedure--was observed in 78% of patients in both series. Three cases of tamponade due to chamber perforation and 14 cases of transient air embolism in the right coronary system due to balloon rupture were observed in the double-balloon series.(ABSTRACT TRUNCATED AT 250 WORDS)

Balloon Occlusion

Percutaneous mitral valvulotomy in non-optimal candidates.

From 1987 to 1990, 215 patients aged 53 +/- 13 years underwent percutaneous mitral valvulotomy in our institution. Mean gradient dropped on average from 13 +/- 4 to 5 +/- 2 mmHg and mitral valve area increased from 1.0 +/- 0.26 to 1.97 +/- 0.5 cm2 at the end of the procedure. Good results, defined as mitral valve area greater than or equal to 1.5 cm2 and mitral regurgitation less than or equal to 2+ at the end of the procedure, were obtained in 78% of the cases. In 41 patients with a poor anatomical form of mitral stenosis, mean gradient decreased from 12 +/- 3 to 6 +/- 6 mmHg and mitral valve area increased from 1.0 +/- 0.3 to 1.7 +/- 0.5 cm2. Good results were obtained in only 50% of the patients. One third of the 3+ mitral regurgitation occurred in this subgroup of patients. In patients with prior surgical commissurotomy, in elderly people and in patients with associated valvulopathy or prosthetic aortic valve, the success rate was similarly low. A significant inverse relationship was found between X-ray and echo scores on the one hand and mitral valve area at the end of the procedure on the other, thus confirming that the results of percutaneous mitral valvulotomy are related to the anatomical form of mitral stenosis. However, patients with poor anatomical forms can undergo the procedure with an acceptable risk compared to benefit ratio.

Adolescent

[Percutaneous mitral valvuloplasty by Inoue's technique. Apropos of an experience of 71 cases].

Seventy-one consecutive, unselected patients underwent percutaneous mitral valvuloplasty by Inoue's technique between February and November 1990. The mean age was 53 years (range 32 to 75 years). Fifteen of the 71 patients had previously undergone surgical mitral commissurotomy. Three patients had Björk aortic valve prostheses. The mitral valve surface area increased from 1.1 +/- 0.2 cm2 to 1.95 +/- 0.5 cm2 (p less than 0.01) and the mean transmitral pressure gradient fell from 12 +/- 3 mmHg to 5 +/- 2 mmHg (p less than 0.05). Grade 3+ mitral regurgitation was observed in 4 patients. There were no cases of cardiac perforation or tamponade. The only complications were related to the catheterisation and not to the technique valvuloplasty (one case of prolonged fever which regressed with antibiotic therapy, one case of arteriovenous fistula at the site of femoral artery puncture). The QP/QS ratio was 1.1 +/- 0.2 at the end of the procedure. A QP/QS ratio greater than 1.5 was observed in one patient. A left-to-right shunt was observed in 53% of cases in the immediate post-valvuloplasty period with Doppler color flow imaging. In all, 78% of patients had a satisfactory result (mitral surface area greater than 1.5 cm2 and mitral regurgitation less than or equal to 2/4). These results are identical to those observed with the double balloon technique with a lower rate of complications. The duration of the procedure (104 +/- 13 min p less than 0.02) and of radioscopy (16 +/- 8 min, p less than 0.02) were shorter than with the double balloon technique.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult

Isotopic findings in anomalous origin of the left coronary artery from the pulmonary artery: report of an adult case.

Anomalous origin of the left coronary artery from the main pulmonary trunk results in myocardial ischemia or infarction, and may be a cause of death in the first months of life. Some patients, however, develop satisfactory coronary collateral circulation and remain asymptomatic into adulthood. In these patients, myocardial perfusion and left ventricular function are not well understood. We report the case of a 17-yr-old female patient, suffering from anomalous origin of the left coronary artery from the main pulmonary trunk, who underwent reimplantation of the left coronary artery to the aorta. The preoperative permanent 201Tl defect of the left antero-lateral ventricular wall and the abnormal regional wall motion induced by stress exercise testing were fully reversed after the operation.

Adolescent

[Results of surgery in mitral valve insufficiency with impaired left ventricular function].

This cooperative study (8 French Cardiology Departments) was undertaken to determine the postoperative outcome of patients with pure, chronic, non-ischemic mitral regurgitation and poor left ventricular function (ejection fraction less than 50%). Seventy-three patients, 48 males and 25 females with a mean age of 55.5 +/- 12.1 years were included. Fifty-eight patients were in Class III or IV of the NYHA Classification. The average cardiothoracic ratio was 0.59 +/- 0.07. Forty-six patients were in atrial fibrillation. The average ejection fraction was 43 +/- 5 per cent (end systolic volume: 97.8 +/- 37.9 ml/m2; end diastolic volume: 175.2 +/- 67.6 ml/m2). Sixty-one patients underwent prosthetic mitral valve replacement and 12 had a Carpentier valvuloplasty. Two patients died after the operation and 20 died during follow-up (average 48.1 +/- 27.6 months), giving a 5 year actuarial survival rate of 69.6 per cent. In the long-term, fifteen per cent of patients were in NYHA Class III or IV. A multivariate Cox analysis showed that the only predictive factors of a poor outcome were age and female sex. These results of surgery for mitral regurgitation with moderate to severely altered left ventricular function were relatively good, but this study does not allow evaluation of the evolution of patients with mitral regurgitation and very poor left ventricular function (no patients with ejection fraction less than 25%).

Actuarial Analysis

[Dystrophic aortic insufficiency: influence of dilatation of the ascending aorta on secondary outcome].

This cooperative study recensed 89 cases of patients operated for aortic regurgitation in whom the dystrophic process was confirmed on anatomical (thin, translucent valves without symphysis, multilation or sclerosis) and histological criteria (mucinous infiltration). They included 81 men (91%) and the average age was 52 +/- 14 years. The valvular degeneration was part of a generalised dystrophy of elastic tissue in 8 patients (6 "formes frustes" of Marfan's syndrome, 2 Lobstein's syndrome). The patients were divided into 2 groups according to the diameter of the ascending aorta measured by echocardiography and/or aortography. In Group 1 (n = 40), the aorta was not dilated (diameter less than 40 mm) whereas in Group 2 (n = 49), the diameter of the ascending aorta was dilated (40-55 mm) but not aneurysmal (loss of parallelism of the aortic walls). The two groups were comparable before surgery with respect to age, sex, functional class, degree of left ventricular dilatation, left ventricular ejection fraction and presence of associated coronary disease). There were no differences in the operative parameters but aortic parietal biopsy (n = 35) revealed clear signs of cystic medianecrosis more often in Group 2 than in Group 1 (14/25 versus 1/10, p less than 0.05). No operative procedure was performed on the ascending aorta during aortic valve replacement. One operative death occurred in each group. After an average follow-up of 4 years, there was a higher mortality in Group 2: the actuarial 7 year survival rate being 74% in Group 1 and 54% in Group 2. This was explained by a higher incidence of ascending aortic complications. Only 1 patient in Group 1 developed an aneurysm of the ascending aorta requiring reoperation compared to 14 patients in Group 2, 8 of whom were reoperated (p less than 0.01). These results suggest that non-aneurysmal dilatation of the ascending aorta in patients with dystrophic aortic regurgitation is a poor prognostic factor because of the high incidence of secondary aortic parietal complications (aneurysm, dissection).

Actuarial Analysis

Aortic valve area evolution after percutaneous aortic valvuloplasty. A prospective trial using a combined Doppler echocardiographic and haemodynamic method.

The aortic valve area was serially evaluated in 45 patients, mean age 78 years, suffering from severe aortic stenosis who underwent percutaneous aortic valvuloplasty. The aortic valve area was calculated from haemodynamic data prior to and immediately after the procedure using the mean gradient. Serial determinations of the aortic valve area were also obtained 1 day before, 1 day after and 2 months after valvuloplasty from the thermodilution cardiac output and Doppler echocardiography mean left ventricle-to-aorta gradient. The mean gradient significantly decreased from 75 +/- 24 to 42 +/- 16 mmHg (P less than 0.01) when measured from haemodynamic data and from 63 +/- 20 to 41 +/- 13 mmHg (P less than 0.01) when estimated from Doppler-derived data. It rose to 48 +/- 15 mmHg at 2 months (NS). The aortic valve area increased significantly from 0.48 +/- 0.13 to 0.67 +/- 0.29 cm2 (P less than 0.01) when calculated from haemodynamic data, and from 0.53 +/- 0.18 to 0.74 +/- 0.23 cm2 (P less than 0.01) when estimated from Doppler-derived data. It declined to 0.69 +/- 0.27 cm2 at 2 months (NS). Aortic valve area values determined from haemodynamic data and from Doppler-derived data correlated well before valvuloplasty (r = 0.80, P less than 0.01) but poorly afterwards (r = 0.57, P less than 0.01). The aortic valve area was not influenced by valvuloplasty in eight patients. At 2 months, restenosis was apparent in eight patients out of 32 that were re-evaluated. Three patients died within 5 days of the procedure. After an average 12 months' follow-up, eight more patients died. Symptoms were not influenced or recurred in 17 patients, while 17 others remained improved by at least one NYHA functional class. Seven patients were operated on, and there was one operative death. The calculated aortic valve area was significantly greater at the end of the procedure in the patients with persistent improvement compared with those with a poor result (0.83 +/- 0.29 cm2 vs 0.65 +/- 0.14 cm2, P less than 0.05). In conclusion, in this study one third of the patients submitted to percutaneous aortic valvuloplasty had no objective improvement in calculated valve area or early restenosis after 2 months. Functional improvement was observed in one third of the patients. Immediate re-estimation of the aortic valve area from haemodynamic data at the end of the procedure may not reflect the actual effect of valvuloplasty on the aortic orifice.

Aged

[Anisoylated plasminogen streptokinase complex during the acute phase of myocardial infarction. Results of a multicenter double-blind study versus heparin].

Two hundred and thirty-one patients admitted to hospital within 5 hours of the onset of symptoms of a primary myocardial infarction were randomised into 2 groups: one received thrombolytic therapy [anisoylated plasminogen streptokinase activator complex (APSAC): 30 IU in 5 minutes] and the other was given conventional heparin therapy (5,000 IU). Heparin was given to both groups 4 hours later (500 IU/kg/day); the APSAC (N = 119) was identical with respect to age, location of infarct, Killip classification, delay before randomisation (188 +/- 62 minutes). Coronary angiography and ventriculography were performed after 3.4 +/- 1.2 days, and angioscintigraphy and myocardial scintigraphy after 19 +/- 2.5 days to determine the size of the infarct and the quality of left ventricular function. Coronary patency was much higher in the APSAC group (77%) than the heparin group (37%) (p less than 0.001). The angiographic ejection fraction was significantly greater in the thrombolytic group than in the heparin group (53 +/- 13% vs 47 +/- 12%, p less than 0.002), the difference being statistically significant in the anterior and inferior infarct subgroups. At the third week, the difference remained significant in the anterior infarct subgroup: a 31 per cent reduction in necrosed myocardial mass was observed in the APSAC group (33% in anterior infarcts: p less than 0.05 and 16% in inferior infarcts: NS). The limitation of infarct size explained the smaller reduction in left ventricular systolic function (r = 0.73; p less than 0.01). The hospital and one year mortality was comparable in the two groups which was not surprising given the small number of patients.(ABSTRACT TRUNCATED AT 250 WORDS)

Anistreplase

[Postoperative course of systolic and diastolic indices of left ventricular function in aortic valve stenosis in adults. Exercise test with radionuclide angiography].

Resting and stress radionuclide angiography was performed before and, on average, one year after surgery for adult aortic stenosis in 26 patients. The left ventricular ejection fraction, ventricular volumes, left ventricular stroke volume and peak velocity of ventricular filling were studied under basal conditions and at the peak of exercise. Right and left heart catheterisation and coronary angiography were performed before surgery with determination of the conventional indices of left ventricular function. Investigations were completed by pre and postoperative echocardiography. The same procedures were carried out in a control population of the same age. Before surgery, hemodynamic adaptation to exercise, judged by the change in left ventricular stroke volume, solicits the passive properties of the left ventricle: the left ventricular stroke volume increases by an increase in the end diastolic volume. In the control group, the increase in stroke volume is obtained by a decrease in end systolic volume, that is to say by increasing systolic shortening. The peak velocity of ventricular filling increases on exercise but to a lesser degree than in the control population. After surgery the hemodynamic adaptation to exercise results from an improved systolic shortening of the left ventricle but also from an increase in end diastolic volume. The peak velocity of left ventricular filling increases with respect to the preoperative values but remains less than that observed in the control population. No relationship was observed between the hemodynamic adaptation to exercise, the peak velocity of ventricular filling and myocardial mass whichever method was used for calculating the latter parameter.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult

[A new treatment of deep venous thrombosis: low molecular weight heparin fractions. Randomized study].

Sixty-eight patients with acute deep vein thrombosis were allocated at random to two treatment groups. One group (n = 33) received a fixed dose of 750 anti-Xa units of a low molecular weight heparin (CY 222 Choay Institute); the other group (n = 35) received standard heparin in doses of 500 IU/kg/24 h. Both treatments were given for 10 days in two daily subcutaneous injections. A second phlebography was performed on the last day of treatment. No haemorrhagic complication was observed in the group treated with CY 222, as opposed to three cases of haemorrhage in the group treated with standard heparin. The initial phlebographic score and the location of deep vein thrombotic lesions were the same in both groups. Angiographic improvement, with more than 30% thrombolysis, was obtained at the end of treatment in 64% of patients in the CY 222 group and in 65% of patients in the standard heparin group (NS). In 2 patients treated with standard heparin the second phlebography showed extension of the thrombosis. The initial score remained unchanged in 1/3 of patients in both groups. The activated partial thromboplastin time was prolonged (2 or 3 fold the normal value) in the standard heparin group and unchanged in the CY 222 group. Anti-Xa activity was significantly higher in the CY 222 group than in the standard heparin group. It is concluded that CY 222 and standard heparin were equally effective in patients with deep vein thrombosis. However, haemorrhagic complications were more frequent with standard heparin that with CY 222.

Aged

Comparison between vertical parallel hole collimator and 30 degrees rotating slant hole collimator for assessing global and regional left ventricular function by radionuclide angiography.

Left ventricular ejection fraction (LVEF) and regional wall motion abnormalities were determined in 40 patients (30 with coronary artery disease and 10 with valvular heart disease) using equilibrium radionuclide angiography. Scintigraphic acquisitions were collected in random order with 2 different collimators as follows: in anterior face (AF), left anterior oblique (25 degrees-45 degrees LAO) and 70 degrees LAO, with a vertical parallel hole collimator (VTC), and in 25 degrees-45 degrees LAO and 65 degrees-80 degrees LAO with a 30 degrees rotating slant hole collimator (RSHC), with the slant of the collimator directed towards the cardiac apex in both projections. Results were compared to contrast ventriculography (CV) performed in the 30 degrees right anterior view (3 segments: anterior, apical, inferior) and in a 60 degrees left anterior oblique view (3 segments: septal, apical and lateral). Radionuclide LVEF in both series was closely correlated with contrast ventriculographic LVEF (r = 0.89, VTC vs CV and r = 0.87, RSHC vs CV, respectively). Regional wall motion analysis was only performed among the 30 patients suffering from coronary heart disease. Eight contrast angiographic studies were normal and 22 abnormal. Global sensitivity and specificity were 100% and 63% with the VTC (3 false positives) and 91% and 87% with the 30 degrees RSHC (2 false negatives and 1 false positive, P = ns). Agreement for the localisation of the regional wall motion abnormalities between CV and radionuclide angiography was 70.6% with the VTC and 71.2% with the RSHC (P = ns).(ABSTRACT TRUNCATED AT 250 WORDS)

Coronary Disease

Adaptation of the left ventricular function parameters to dynamic exercise in aortic stenosis.

The left ventricular volumes, the left ventricular ejection fraction, the stroke volume index and the cardiac index were non-invasively determined in 47 patients suffering from moderate to severe pure aortic stenosis using radionuclide angiography at rest and at peak supine exercise. Each patient was previously submitted to right and left heart catheterization and to selective coronary angiography. The left ventricular ejection fraction decreased significantly during exercise (0.62 +/- 0.09 to 0.59 +/- 0.09, P less than 0.01). End-systolic volume, end-diastolic volume, stroke volume index and cardiac index increased significantly. The stroke volume variations were linked to the end-diastolic volume variations by a strong relationship (r = 0.84, P less than 0.001) and to left ventricular mass by a weak, but significant, inverse relationship (r = -0.42, P less than 0.05). No relation existed between stroke volume index variations and any other variables, particularly systolic gradient, aortic valve area and resting left ventricular ejection fraction. The results suggest that, in aortic stenosis, the adaptation of the left ventricular pump function during exercise is mostly dependent upon the diastolic properties of the left ventricular wall and is limited by the progression of left ventricular hypertrophy, i.e. diastolic stiffness. By contrast, the role of the basal systolic pump function and of the severity of the valvular obstruction seems of limited importance.

Adult