Staging urinary bladder cancer: value of T1-weighted three-dimensional magnetization prepared-rapid gradient-echo and two-dimensional spin-echo sequences.

OBJECTIVE: The purpose of this study was to evaluate a magnetization prepared-rapid gradient-echo (MP-RAGE) sequence as a three-dimensional T1-weighted MR imaging technique for staging urinary bladder cancer and to compare this technique with a commonly used two-dimensional T1-weighted spin-echo sequence technique. SUBJECTS AND METHODS: For 28 consecutive patients with urinary bladder cancer, MR findings and staging results were compared with histopathologic findings after surgery or autopsy. MR imaging was performed at 1.5 T with a Helmholtz double-surface coil. Conventional T1-weighted spin-echo, three-dimensional MP-RAGE, T2-weighted spin-echo or turbo-spin-echo, and dynamic T1-weighted fast gradient-echo sequences were used. Signal difference-to-noise ratios and T1 contrast were calculated by use of operator-defined regions of interest. RESULTS: The signal difference-to-noise ratios for fluid-tumor and fat-tumor were, respectively, factors of 1.6 and 2.7 better with T1-weighted spin-echo sequences. T1 contrast of fluid-tumor was a factor of 2.6 better with three-dimensional MP-RAGE sequences, resulting in better recognition of small tumors, ascites, and dilated ureters. T1 contrast for fat-tumor was a factor of 2.0 better with T1-weighted spin-echo sequences. With the MP-RAGE sequence, motion artifacts were fewer in number than those noted with the T1-weighted spin-echo sequence, and susceptibility artifacts were equal in number to those noted with the T1-weighted spin-echo sequence. Using the three-dimensional technique, we performed off-line reconstruction of 1- to 2-mm high-resolution images in every desired plane. Because of higher spatial resolution, the availability of multiplanar reconstructions, and better fluid-tumor contrast and despite lower signal difference-to-noise ratios, three-dimensional MP-RAGE images resulted in better recognition of local tumor extension (n = 11), adhesions and bowel wall invasion (n = 5), lymph node metastases (n = 2), and bone marrow metastases (n = 2). The staging accuracy for the combination of three-dimensional MP-RAGE, T2-weighted, and dynamic sequences was 93%; that for the combination of two-dimensional T1-weighted spin-echo, T2-weighted, and dynamic sequences was 78%. Nodal staging was also more accurate with MP-RAGE sequences (accuracy of 93% vs 86% for T1-weighted spin-echo sequences). CONCLUSION: Compared with two-dimensional T1-weighted spin-echo imaging, three-dimensional MP-RAGE imaging resulted in a 15% improvement in staging. Our findings suggest that optimal staging of urinary bladder carcinoma requires three-dimensional imaging techniques.

Adult

Optimization of parameter values for complex pulse sequences by simulated annealing: application to 3D MP-RAGE imaging of the brain.

A number of pulse sequence techniques, including magnetization-prepared gradient echo (MP-GRE), segmented GRE, and hybrid RARE, employ a relatively large number of variable pulse sequence parameters and acquire the image data during a transient signal evolution. These sequences have recently been proposed and/or used for clinical applications in the brain, spine, liver, and coronary arteries. Thus, the need for a method of deriving optimal pulse sequence parameter values for this class of sequences now exists. Due to the complexity of these sequences, conventional optimization approaches, such as applying differential calculus to signal difference equations, are inadequate. We have developed a general framework for adapting the simulated annealing algorithm to pulse sequence parameter value optimization, and applied this framework to the specific case of optimizing the white matter-gray matter signal difference for a T1-weighted variable flip angle 3D MP-RAGE sequence. Using our algorithm, the values of 35 sequence parameters, including the magnetization-preparation RF pulse flip angle and delay time, 32 flip angles in the variable flip angle gradient-echo acquisition sequence, and the magnetization recovery time, were derived. Optimized 3D MP-RAGE achieved up to a 130% increase in white matter-gray matter signal difference compared with optimized 3D RF-spoiled FLASH with the same total acquisition time. The simulated annealing approach was effective at deriving optimal parameter values for a specific 3D MP-RAGE imaging objective, and may be useful for other imaging objectives and sequences in this general class.

Adipose Tissue

Three-dimensional time-of-flight MR angiography using selective inversion recovery RAGE with fat saturation and ECG-triggering: application to renal arteries.

A three-dimensional (3D), ECG-triggered, selective inversion recovery (SIR) rapid gradient-echo (RAGE) technique is proposed to obtain MR angiograms of the main renal arteries. By using the selective inversion recovery and fat saturation, the background is significantly suppressed while blood maintains a high signal intensity as compared with conventional 3D time-of-flight (TOF) MR angiography. The sequence is ECG-triggered so that blood in-flow is maximized during systole, and intravoxel dephasing and pulsatile flow artifacts are minimized by collecting data during diastole. As a result, vessel boundary blurring and ghosting artifacts due to background motion are dramatically reduced, and the conspicuity and lumen definition of the arteries are significantly improved. High-quality MR angiograms of the main renal arteries with excellent blood/tissue contrast and suppression of motion artifacts have been consistently obtained for normal volunteers, with the length of visualization being 51 +/- 07 mm for the left, and 57 +/- 06 mm for the right renal arteries, significantly greater than using conventional 3D TOF pulse sequences. Statistical analysis was performed by using a one-sided Student's t test.

Angiography

MR imaging of the liver: breath-hold T1-weighted MP-GRE compared with conventional T2-weighted SE imaging--lesion detection, localization, and characterization.

PURPOSE: To compare breath-hold T1-weighted magnetization-prepared gradient-echo (MP-GRE) imaging with conventional T2-weighted spin-echo (SE) imaging in evaluation of focal liver disease. MATERIALS AND METHODS: Images of 68 patients evaluated for focal liver disease were reviewed. Five sets of images were analyzed: axial, sagittal, and coronal breath-hold T1-weighted MP-GRE images, axial T2-weighted SE images, and a compilation of axial, sagittal, and coronal (three-plane) T1-weighted MP-GRE images. Lesion signal intensity (SI) and signal difference-to-noise (SD/N) ratios were calculated. RESULTS: Lesions were detected, localized, and characterize more accurately (P < .05-.001) and with greater confidence on three-plane T1-weighted MP-GRE images than on almost all single-plane images. Mean SI ratios of nonsolid and solid lesions on MP-GRE and SE images were significantly different at all lesion sizes; mean SD/N ratio was significantly different only for large lesions. CONCLUSION: Lesion detection, localization, and characterization can be accurately and confidently performed with three-plane T1-weighted MP-GRE breath-hold imaging, potentially obviating conventional T2-weighted SE imaging.

Artifacts

The design of pulse sequences employing spatial presaturation for the suppression of flow artifacts.

The use of spatial presaturation to suppress the signal, and therefore also the artifacts, from flowing blood has become an important tool in the arsenal of techniques to suppress pulsatile flow artifacts in magnetic resonance images. However, a detailed theoretical analysis of the behavior of these flow artifact suppression pulses and of the important aspects of implementing suppression pulses in combination with particular imaging sequences has yet to be presented. In this paper we present a general theoretical framework to describe the flow artifact suppression technique. This analysis addresses the following four major issues: (1) the spin washout characteristics of the imaging sequence, (2) the interference between the flow signal suppression pulses and the imaging sequence, (3) the flow velocity range for a single application of the suppression pulse, and (4) the total flow velocity range for a suppression pulse repeated with a constant time interval between applications of the pulse. The predictions of our theoretical model are confirmed by experimental measurements made with stationary and flow phantoms. The results of this investigation provide guidelines for the design of flow artifact suppression pulse sequences and, in addition, should aid in the future development and refinement of the spatial presaturation technique as applied to flow signal suppression.

Artifacts

Shaping the signal response during the approach to steady state in three-dimensional magnetization-prepared rapid gradient-echo imaging using variable flip angles.

A theoretical algorithm for shaping the signal response during the approach to steady state in three-dimensional magnetization-prepared rapid gradient-echo (3D MP-RAGE) pulse sequences has been developed and implemented. This algorithm derives the flip angle series required to produce specifically chosen time evolutions of the signal intensities during the data acquisition segment of 3D MP-RAGE sequences. Theoretical predictions for the cases of unshaped, uniform, and mono-exponential decay signal responses were quantitatively validated with a doped-water phantom on a 1.5-T whole-body imager and in all cases there was excellent agreement between the theoretical and experimental values. The effects of RF inhomogeneities and eddy currents on the signal response shaping were also investigated. To demonstrate the potential utility of the technique, the signal response shaping algorithm was applied to a T1-weighted 3D MP-RAGE sequence to derive the acquisition flip angle series which theoretically yields the maximum white matter/gray matter signal difference (WGSD) consistent with the chosen response shape. Images obtained from a healthy volunteer using this variable flip angle sequence were compared with 3D RF-spoiled steady-state gradient-echo images obtained in the same total imaging time. The 3D MP-RAGE images demonstrated a 41% increase in the WGSD-to-noise ratio. These initial very promising results indicate that with further refinement to eliminate some intensity artifacts, the variable flip angle 3D MP-RAGE technique may, with respect to certain image properties, provide considerable improvements over currently available 3D gradient-echo imaging techniques.

Algorithms

Potential degradation in image quality due to selective averaging of phase-encoding lines in Fourier transform MRI.

The properties of the image noise for selective averaging of phase-encoding lines have been investigated. For a given acquisition time, selective averaging results in a signal-to-noise ratio penalty compared to averaging all lines equally. In addition, selective averaging yields a non uniform distribution of noise characteristics in spatial frequency space, which can result in a change in the texture of the image noise.

Fourier Analysis

Magnetization prepared rapid gradient-echo (MP-RAGE) MR imaging of the liver: comparison with spin-echo imaging.

We have implemented an MR technique that employs a rapid gradient echo sequence, preceded by magnetization preparation pulses to provide T1- and T2-weighted tissue contrast. With this technique, which can be identified as a member of a new family of pulse sequences, generically named Magnetization Prepared RApid Gradient Echo (MP-RAGE), very short repetition times are used, allowing acquisition times of less than one second and images virtually free of motion-induced artifacts during quiet respiration. Fifteen patients with known liver lesions (metastases, hemangiomas, and cysts) were examined using T1- and T2-weighted 2-dimensional MP-RAGE sequences, and the images were compared with conventional T1- and multi-echo T2-weighted spin-echo (SE) sequences. Signal difference-to-noise ratios (SD/Ns) of the lesions were calculated for all pulse sequences using corresponding axial images and were normalized for voxel volume. The mean normalized SD/Ns of the MP-RAGE sequences were generally comparable to those for the SE sequences. In addition, there were no noticeable respiratory artifacts on the MP-RAGE images whereas these were clearly present on the T2-weighted SE images and to a lesser degree on the T1-weighted SE images. It is concluded that the MP-RAGE technique could become an important method for evaluating the liver for focal disease.

Cysts

Three-dimensional magnetization-prepared rapid gradient-echo imaging (3D MP RAGE).

A new three-dimensional imaging technique which is applicable for 3D MR imaging throughout the body is introduced. In our preliminary investigations we have acquired high-quality 3D image sets of the abdomen showing minimal respiratory artifacts in just over 7 min (voxel size 2.7 X 2.7 X 2.7 mm3), and 3D image sets of the head showing excellent gray/white contrast in less than 6 min (voxel size 1.0 X 2.0 X 1.4 mm3).

Abdomen

Identification and 3-D quantification of atherosclerosis using magnetic resonance imaging.

Cardiovascular disease due to atherosclerosis is a leading cause of death in the United States as well as other developed countries. This paper describes the development of image processing, pattern recognition, and graphical display techniques to non-invasively quantify the atherosclerotic disease process using magnetic resonance imaging (MRI). We have demonstrated the ability to identify the soft tissue classes of (1) normal, smooth muscle wall, (2) fatty plaque, (3) complex, fibrous plaque, and (4) calcified plaque. The objective of this work has been to combine functional information, such as plaque tissue type, with structural information, represented by 3-D display of vessel structure, into a single composite display. The results of this work provide a "high information content" display which will aid in the diagnosis and analysis of the atherosclerotic disease process, and permit detailed and quantitative studies to assess the effectiveness of therapies (e.g. changes in diet, exercise and drug administration).

Aorta

Liver metastases: optimization of MR imaging pulse sequences at 1.0 T.

Twenty patients with known liver metastases were examined with magnetic resonance imaging; four different pulse sequences were used and six different images were produced to allow comparison of pulse sequence performance at a 1.0-T field strength. Pulse sequence performance was in each case calculated by measuring contrast-to-noise ratios (C/N) comparing normal liver, metastatic tumors to liver, and background noise. All pulse sequences required approximately the same length of time for data acquisition. Short inversion time inversion-recovery (STIR) sequences yielded the greatest signal difference-to-noise ratio in 17 patients. Phase contrast images produced the greatest contrast ratio in three patients. Although short TR, short TE spin-echo sequences provided the best anatomic detail, in no patient did this sequence yield the greatest signal difference-to-noise ratio in the comparison of liver and tumor. Differences in field strength and in equipment software and hardware may account for the discrepancy between our findings and previously published data.

Humans

Tumor detection with phase-contrast imaging: an evaluation of clinical potential.

The conspicuity of a variety of human tumors outside the liver, with a broad spectrum of histologic types, was evaluated using phase-contrast imaging (proton chemical shift imaging, proton spectroscopy) and the results compared with the data obtained using routine T1- and T2-weighted magnetic resonance (MR) imaging sequences. In all cases, tumors were most conspicuous using the phase-contrast technique. In two instances, the tumors could be discerned only by this method, being undetectable by any routine MR pulse sequence. The use of phase-contrast imaging is recommended as an adjunct to standard MR sequences when evaluating for either the presence or extent of a tumor, regardless of its anatomic location or histologic type.

Adipose Tissue

Evaluation of a simple method for reconstructing asymmetrically sampled echo data.

A simple method for reconstructing echo data with a large degree of sampling asymmetry was investigated. The method is based on the application of an optimized data sampling window before standard Fourier transform magnitude reconstruction. The performance of this "windowed direct" reconstruction was evaluated with theoretical simulations and experimental measurements and compared with that of the half-Fourier method. With the proper selection of data sampling window parameters, highly asymmetric echo data reconstructed with standard Fourier transform magnitude algorithms produced images similar in quality to those reconstructed with the half-Fourier method. Windowed direct reconstruction provides a simple and computationally fast alternative to more sophisticated algorithms and may be particularly applicable for specialized or developmental applications.

Evaluation Studies as Topic

Clinical comparison of three-dimensional MP-RAGE and FLASH techniques for MR imaging of the head.

Three-dimensional (3D) MP-RAGE (magnetization-prepared rapid gradient-echo) imaging was evaluated as a high-resolution 3D T1-weighted brain imaging technique for patients with suspected neurologic disease. Fourteen patients were studied. In five, 3D MP-RAGE images were compared with 3D FLASH (fast low-angle shot) images. Signal difference--to-noise ratios and T1 contrast were not statistically different for 3D MP-RAGE images as opposed to 3D FLASH images. Advantages intrinsic to the application of 3D MP-RAGE sequences include decreased imaging time and decreased motion artifact. With this technique, it is possible to perform a relatively motion-insensitive, T1-weighted screening brain study with voxel resolution of 1.0 x 1.4 x 2.0 mm or smaller, in an imaging time of 5.9 minutes or less--permitting offline (poststudy) reconstruction of high-resolution images in any desired plane.

Brain

Rapid three-dimensional T1-weighted MR imaging with the MP-RAGE sequence.

The authors investigated the application of three-dimensional (3D) magnetization-prepared rapid gradient-echo (MP-RAGE) imaging to the acquisition of small (32 x 128 x 256) T1-weighted 3D data sets with imaging times of approximately 1 minute. A theoretical model was used to study the contrast behavior of brain tissue. On the basis of these theoretical results, 3D MP-RAGE sequences were implemented on a 1.5-T whole-body imager. Thirty-two-section 3D data sets demonstrating good signal-to-noise ratios and resolution and strong T1-weighted contrast were obtained in 1 minute. Compared with standard short TR/TE spin-echo sequences with the same imaging times and comparable sequence parameters, the 3D MP-RAGE sequence delivered increases of more than 50% in the white matter/gray matter signal difference-to-noise and white matter signal-to-noise ratios, and provided almost twice as many sections. These sequences may find a clinical role in 3D scout imaging and screening and in patients with claustrophobia or trauma.

Brain

T2-weighted three-dimensional MP-RAGE MR imaging.

The application of three-dimensional (3D) magnetization-prepared rapid-gradient-echo (MP-RAGE) imaging to the acquisition of T2-weighted 3D data sets has been investigated, with a 90 degrees x-180 degrees y-90 degrees-x pulse set (driven equilibrium) for the T2 contrast preparation. A theoretical model was used to study the contrast behavior of brain tissue. The effects of radio-frequency and static-field inhomogeneities and eddy currents on the T2 contrast preparation and the effects of eddy currents on the gradient-echo acquisition resulted in blurring and intensity banding artifacts. With a multistep gradient preparation, these artifacts could be suppressed. With further development, this technique may yield a clinically practical method for obtaining T2-weighted 3D data sets of relatively large volumes (eg, the whole head) suitable for multiplanar reformatting.

Artifacts

Selective versus nonselective preparation pulses in two-dimensional MP-RAGE imaging of the liver.

The use of a section-selective preparation pulse in two-dimensional (2D) T1-weighted magnetization-prepared rapid gradient-echo (MP-RAGE) imaging of the liver was investigated. The images were compared with those obtained with a nonselective pulse. The performances of the sequences were evaluated in 11 patients with 12 focal liver lesions, and lesion-liver and lesion-vessel signal difference-to-noise ratios (SD/Ns) were calculated. With the section-selective preparation pulse, small lesions were better differentiated from vessels, and multiple, consecutive images could be obtained at shorter intervals. The mean lesion-liver SD/N was slightly but not significantly greater for images obtained with a selective pulse, while the lesion-vessel SD/N was significantly greater (P less than .01). It is concluded that a section-selective preparation pulse can improve the clinical utility of the 2D MP-RAGE sequence in the evaluation of focal liver disease.

Humans

Improved T1-weighted two-dimensional MP-GRE imaging of the liver with variable flip angles for shaping the signal evolution.

The recently introduced method of shaping the transient signal evolution in magnetization-prepared gradient-echo (MP-GRE) imaging with variable flip angles has been applied to two-dimensional (2D) MP-GRE imaging of the abdomen. The technique was analyzed by using theoretical models and was implemented on a standard 1.5-T whole-body imager with a segmented acquisition. Theoretical models predicted that the variable-flip-angle 2D MP-GRE sequence would increase liver-spleen signal difference--to-noise ratios by 290%, 110%, and 160% compared with a 2D MP-GRE sequence with a flip angle of 10 degrees and sequential phase encoding, a 2D MP-GRE sequence with a flip angle of 30 degrees and centric phase encoding, and the fast low-angle shot sequence, respectively. Experimental measurements supported the theoretical predictions.

Algorithms