PubMed Health⌕ Search

Biomedical subjects

J P Ou

Publications and source records attributed to J P Ou.

4 recordsLinked to original sources

Comparison of the survival of human biopsied embryos after cryopreservation with four different methods using non-transferable embryos.

BACKGROUND: The standard embryo cryopreservation method is still less than optimal for biopsied embryos. The aim of this study was to compare the survival of biopsied embryos cryopreserved with four different methods using non-transferable embryos. METHODS: Abnormal embryos from one or three pronuclei and spare embryos of grade 3 and 4 were used for this study. Non-biopsied embryos were cryopreserved using the standard method as control. Biopsied embryos were cryopreserved using four methods as follows: standard method, modified freezing method, modified thawing method and vitrification. Blastomere survival and blastulation of frozen-thawed embryos were compared between the different methods. RESULTS: The proportion of embryos with > or = 50% blastomere survival and total blastomere survival rate of biopsied embryos were significantly higher with vitrification than the other three methods. Both the modified freezing and modified thawing methods had significantly higher embryo survival and total blastomere survival rates than standard methods. However, there was no significant difference in blastulation of surviving embryos in all the five groups. CONCLUSIONS: Non-transferable embryos derived from clinical IVF/ICSI are useful for evaluation of the optimal freezing procedures for biopsied embryos. Vitrification increases the survival rate of human biopsied embryos above standard and modified cryopreservation methods.

Biopsy↗

Capillary electrophoresis-based immunoassay.

Capillary electrophoresis-based immunoassay (CEIA) is a developing analytical technique with a number of advantages over conventional immunoassay, such as reduced sample consumption, simpler procedure, easy simultaneous determination of multiple analytes, and short analysis time. However, there are still a number of technical issues that researchers on CEIA have to solve before the assay can be more widely used. These issues include method to improve the concentration sensitivity of the assay, requirement for robust separation strategy for different analytes, and method to increase the throughput of the assay. The approaches to solve these issues are reviewed. Several studies have been devoted to develop general separation strategies for CEIA, and to enhance the sensitivity of detection. The recent development of microchip-based CEIA is encouraging and is likely to address more drawbacks of CEIA, particularly on the throughput issue.

Antigen-Antibody Reactions↗

Separation of bovine serum albumin and its monoclonal antibody from their immunocomplexes by sodium dodecyl sulfate-capillary gel electrophoresis and its application in capillary electrophoresis-based immunoassay.

A non-competitive immunoassay was performed by sodium dodecyl sulfate-capillary gel electrophoresis with UV detection using bovine serum albumin (BSA) and monoclonal anti-BSA. BSA, anti-BSA and their immunocomplexes were well resolved under non-denaturing conditions. A linear calibration curve was obtained and can be used for the quantification of anti-BSA. The limit of detection of anti-BSA was 0.1 microM under the present conditions. Compared with capillary zone electrophoresis, we believed that this method has the potential to be used as a more general format for performing capillary electrophoresis-based immunoassay of medium- and large-sized analytes.

Antibodies, Monoclonal↗

Use of capillary electrophoresis-based competitive immunoassay for a large molecule.

A systematic study on the optimization of capillary electrophoresis-based immunoassay (CEIA) was performed using bovine serum albumin (BSA) and monoclonal anti-BSA. The immunocomplex could not be resolved from free BSA or anti-BSA with UV detection. When fluorescein isothiocyanate-labeled BSA (FITC-BSA) was used as tracer, the free and bound FITC-BSA were well separated giving definite peaks with laser induced fluorescence detection. The factors affecting the separation of the free and bound FITC-BSA, including voltage, pH and ionic strength of the running buffer, were systematically analyzed. Competitive CEIAs were demonstrated in uncoated and coated capillaries with whole or Fab fragment of the antibody. The coefficient of variation for the quantification of BSA in coated capillary was less than that in uncoated capillary. This study demonstrated that competitive CEIA could be applied to quantify high-molecular-mass protein in biological fluids.

Antibodies, Monoclonal↗