PubMed Health⌕ Search

Biomedical subjects

J P Patau

Publications and source records attributed to J P Patau.

5 recordsLinked to original sources

Boron neutron capture irradiation: setting up a clinical programme in Nice.

Neutron capture irradiation aims to selectively destroy tumor cells using 10B(n,alpha)7Li nuclear reactions produced within themselves. Following the capture reaction, an alpha particle and a, 7Li ion are emitted. Carrying an energy of 2.79 MeV, they destroy all molecular structures along their path close to 10 microns. These captures, used exclusively with a 'slow' neutron irradiation, provide a neutron capture therapy (BNCT). If they are used in addition to a fast neutron beam irradiation, they provide a neutron capture potentiation (NCP). The Centre Antoine-Lacassagne in Nice is actively involved in the European Demonstration Project for BNCT of grade IV glioblastomas (GBM) after surgical excision and BSH administration. Taking into account the preliminary results obtained in Japan, work on an 'epithermal' neutron target compatible with various cyclotron beams is in progress to facilitate further developments of this technique. For NCP, thermalized neutron yield has been measured in phantoms irradiated in the fast neutron beam of the biomedical cyclotron in Nice. A thermal peak appears after 5 cm depth in the tissues, delayed after the fast neutron peak at 1.8 cm depth. Thus, a physical overdosage of 10% may be obtained if 100 ppm of 10B are assumed in the tissues. Our results using CAL 58 GBM cell line demonstrate a dose modification factor (DMF) of 1.19 when 100 ppm of boric acid are added to the growth medium. Thus for the particles, issued from neutron capture, a biological efficiency at least twice that of fast neutrons can be derived. These results, compared with historical data on fast neutron irradiation of glioblastoma, suggest that a therapeutic window may be obtained for GBM.

Boron Neutron Capture Therapy↗

Circadian changes in the elimination of misonidazole in mouse.

Intraperitoneal doses of Misonidazole were administered at 15.00 hours and 03.00 hours to Balb c/cenlco mice standardized in controlled environmental cages for 3 weeks before the experiment. Non linear pharmacokinetic and temporal variations in the apparent half life were obtained at higher doses.

Animals↗

Comparison between experimental measurements and calculated transport simulation for electron dose distributions inside homogeneous phantoms.

Comparison is made between dosimetric results measured on electron beams delivered by the three medical accelerators Sagittaire, Saturne and Neptune built by CGR MeV with the results simulated by a Monte Carlo method. In depth, the differences are small for moderate energies with scanned electron beams. In the penumbra region, the differences are small in all cases.