PubMed Health⌕ Search

Biomedical subjects

J P Pequignot

Publications and source records attributed to J P Pequignot.

5 recordsLinked to original sources

[A adaptive proximal scaphoid implant].

INTRODUCTION: In this study, the insertion of a pyrocarbon implant (APSI) has been described, which is shaped to allow adaptive mobility during carpal movement in the first row of carpals. This implant replaces the proximal part of the scaphoid; it is designed to treat styloscaphoid arthritis, and to prevent further deterioration and carpal collapse by restoring the first carpal row to its original height, i.e., 'SNAC wrist' after scaphoid pseudoarthritis, and 'SLAC wrist' following scapho-lunate dissociation. MATERIALS AND METHOD: This retrospective series included 25 cases which were examined and analyzed at an average of six years post-surgery (between three and ten years) by an independent observer using the EVAL expert database system: 1) 14 cases involved pseudoarthritis, which developed from the scaphoid ('SNAC wrist'); 2) ten cases were connected with scapho-lunate nonunion ('SLAC wrist'); 3) one case involved carpal collapse with siliconite, which had previously been inserted as a scaphoid silicone partial implant for the treatment of pseudoarthritis involving a stage II fracture. RESULT: In all cases, the reason for the preoperative-consultation for degenerative arthritis was the presence of pain, which post-surgery was no longer apparent in 60% of cases, and only persisted during effort in 28% of cases. Thus 88% of the patients were satisfied with the results, and were able to resume their normal professional and sports activities at the same level as before. Strength connected with digitopalmar grip and pinch force were found to have increased compared to the function in the healthy hand. No implant dislocation was detected by radiological investigation. Dynamic X-rays of the implant in flexion, extension, and frontal inclination confirmed this adaptive mobility. Carpal height was in all cases maintained. The radio-lunate angle remained unchanged in 15 cases, was improved in six cases, and was worse in four cases. Two poor results were connected with severe ligament lesions prior to surgery. CONCLUSION: The preliminary results regarding the APSI implant seem to be promising for cases of polar pseudoarthritis in which curative treatment is no longer possible. This technique avoids further deterioration and carpal collapse ('SNAC wrist'). However, in cases of scapho-lunate nonunion ('SLAC wrist') where ligament lesions are severe, this method does not resolve the problem of ligament destabilization, which requires further treatment.

Adult↗

Gracilis blood supply: anatomical and clinical re-evaluation.

In a review of 20 gracilis flaps in 18 patients, variations in flap viability have been found. In response to these findings, a detailed anatomical study was performed in 15 fresh cadavers. Selective dye injections evaluated the limits of the skin paddle depending on the dominant pedicle. Most of the musculocutaneous perforators were in the upper two-thirds of the gracilis. In one selected application the main blood supply to the skin was recognised to be proximal. Despite the variations in viability, the flap proved to be a versatile and totally adequate tool.

Adult↗

Extensor digitorum brevis as an island flap in the reconstruction of soft-tissue defects in the lower limb.

The extensor digitorum brevis island flap is a versatile and robust flap able to provide adequate bulk and coverage in soft-tissue defects of the lower limb. The donor-site deformity is limited to the necessary scar needed to approach and rotate the muscle. An anatomic study was performed in 10 fresh cadavers and consisted of two parts: study of the muscle flap itself, and examination of skin vascularization. Methylene blue and Salmon's mass (radiopaque) were injected through the three main arteries of the leg. Muscle and cutaneous staining were noted. Clinical applications of this flap are reported. These resulted in successful healing of the defect with good aesthetic and functional results on both recipient and donor sites. Long-term follow-up was maintained for up to 21 months.

Adolescent↗

Swanson trapezial implant in the treatment of peritrapezial arthrosis. A study of eighty cases.

Eighty cases of peritrapezial arthritis of the thumb treated by Swanson's trapezial implant have been reviewed by the authors. They advocate a slightly modified technique and emphasize the importance of "varisation" of the implant and of correct resection of the greater multangular bone. Follow-up was at least one year in all cases, maximum 10 years, the mean being 3 1/2 years. Results were judged as very good in 75% of the cases, fair in 20% and poor in 5%. This study emphasized the cases of failure by implant instability and its causes. In 8 cases, abnormal wear of the implant or of the scaphoid bone raises the question of long-term tolerance of silicone implants.

Arthritis↗

[Arthroplasty for scaphotrapeziotrapezoidal arthrosis using a pyrolytic carbon implant. Preliminary results].

INTRODUCTION: The authors propose a scaphotrapeziotrapezoidal (STT) arthroplasty using a discoid pyrocarbon implant. The aim of this prosthesis is to restore the scapho-trapezial mobility without destabilising the carpal bones (unlike with a simple resection of the distal scaphoid pole). METHOD: This technique was used in 15 cases from 1994 to 2002. 12 patients (10 females and 2 males), mean age 65 years) have been reviewed with a mean follow-up of 4 years (1 to 8). Surgical indication was pain refractory to medical treatment (average 8.5 on V.A.S.). Pre-operative mobility showed a loss of radial deviation and dorsal flexion. The severity of the pain did not allow evaluation of the pre-operative strength. Post-operative results were assessed with the EVAL computerised system, static and dynamic X rays were performed in all cases. RESULTS: Pain decreased to an average of 2. The mobility compared to the healthy side showed a slight loss of radial deviation (less than 10 degrees) and in wrist extension (less than 15 degrees). Grip strength was similar to the normal side, even during rapid exchanges. Pinch grip evaluation showed a slight decrease (0.8 kg) which did not compromise normal function of the first ray. No implant luxation was observed in the radiological study. Angular measurements did not show any modification in DISI and other static angles remained unchanged. Dynamic sagital and frontal views confirmed the good mobility of the prosthesis which adjusts its position to the scaphoid movements. CONCLUSION: The good results, the simple surgical procedure, the absence of complications, the lack of a need for any fixation or ligamentoplasty all confirm the advantages of this pyrocarbon implant in the treatment of STT arthrosis. Furthermore, in cases of failure, it is possible to use any other revision procedure.

Aged↗