PubMed Health⌕ Search

Biomedical subjects

J P Preece

Publications and source records attributed to J P Preece.

11 recordsLinked to original sources

Effects of time compression and time compression plus reverberation on the intelligibility of Northwestern University Auditory Test No. 6.

The Tonal and Speech Materials for Auditory Perceptual Assessment, Disc 1.0 audio compact disc developed in 1992 includes several sets of degraded speech materials, two of which, time compression and reverberation, are described in this paper. The digital techniques used to compress the NU No. 6 materials (female speaker) on an 80386-based computer are described, along with a series of experiments on subjects with normal hearing that document the effects of the time compression on recognition performance. Experiment I examined at 70 dB SPL the effect on word recognition of 45, 55, 65, 70, and 75 percent compressions. Experiment II developed psychometric functions for the 45, 65, and 75 percent time-compression conditions. Experiment III defined the effects that time-compression degradation (45% and 65%) plus reverberation degradation (0.3 sec) had on the recognition performance on the NU No. 6 materials. Based on the experiments, four conditions (45% compression, 65% compression, 45% compression plus 0.3-sec reverberation, and 65% compression plus 0.3-sec reverberation) were selected and recorded on the compact disc. In the compact disc trials, normative data on the four conditions were developed from 120 listeners with normal hearing.

Compact Disks↗

Natural vowel perception by patients with the ineraid cochlear implant.

Vowel recognition was tested in 10 patients using the Ineraid cochlear implant. The vowels were produced by a male speaker in the context 'heed, hid, head, had, hawed, hood, who'd, hud' and 'heard'. Performance varied from 34 to 93% correct. A descriptive feature system for the vowels was determined from an acoustic analysis. An information transfer analysis of these features suggested that information about the first formant frequency, vowel duration and fundamental frequency was transmitted. Information about the second and third formant frequency was transmitted less well. A sequential information transmission analysis suggested that the features of the first formant and duration accounted for nearly 80% of the information transmitted. The fundamental frequency and second formant frequency information accounted for an additional 8%. Information provided by the third formant frequency was largely redundant.

Adult↗

Relationship of pure-tone averages to speech reception threshold for male and female speakers.

The availability of a compact disc with a female speaker for clinical use has raised the issue of the equivalence between the female speaker and the previous standard male speaker for assessing the speech reception threshold (SRT). This study evaluated the relationship of two- and three-frequency averages to the SRT for a male speaker on an audio tape and a female speaker on a compact disc in two similar groups of clinic patients, each consisting of 215 ears. There were no significant differences between the SRTs for the two groups, suggesting that the two speakers/recordings are equivalent for clinical purposes. The SRTs from both speakers/recordings were within 6 dB of both the two- and three-frequency averages. There were no significant differences between the SRTs and the three-frequency average.

Acoustic Stimulation↗

Enhancement of word-recognition performance with a filtering technique.

The NU No. 6 materials spoken by a female speaker were passed through a notch filter centered at 247 Hz with a 34-dB depth. The filtering reduced the amplitude range within the spectrum of the materials by 10 dB that was reflected as a 7.5-vu reduction measured on a true vu meter. Thus, the notch filtering in effect changed the level calibration of the materials. Psychometric functions of the NU No. 6 materials filtered and unfiltered in 60-dB SPL broadband noise were obtained from 12 listeners with normal hearing. Although the slopes of the functions for the two conditions were the same, the functions were displaced by an average of 5.8 dB with the function for the filtered materials located at the lower sound-pressure levels.

Analog-Digital Conversion↗

Temporal-gap detection by cochlear prosthesis users.

Minimum-detectable gaps for sinusoidal stimuli were measured for three users of a multi electrode cochlear prosthesis as functions of stimulus level, frequency, and electrode place within the cochlea. Stimulus level was scaled by sensation level and by growth-of-loudness functions generated for each condition by direct magnitude estimation. Minimum-detectable gaps decreased with increase in either sensation level or loudness, up to a plateau. When compared at equal sensation levels, the minimum-detectable gaps decreased with frequency increases. The frequency effect on minimum-detectable gaps is reduced if the data are considered at equal loudness. Comparison across place of stimulation within the cochlea showed minimum-detectable gaps to be shorter for more basal electrode placement at low stimulus levels. No differences in minimum-detectable gap as a function of place were found at higher stimulus levels.

Adult↗

Detection, loudness, and discrimination of five-component tonal complexes differing in crest factor.

The detection, loudness, and discrimination performances of subjects with normal hearing were assessed using 3 five-component tonal complexes (1020-1100 Hz) with crest factors of 1.8, 2.6, and 3.2. The 3 five-component tonal complexes were: (1) equally detectable in broadband noise when presented at equal rms amplitude; (2) perceived as equally loud when presented at essentially equal rms amplitude; and (3) discriminable from one another when presented at equal loudness. The present data indicate that listeners can make discriminations on the basis of amplitude variations.

Acoustic Stimulation↗

Previous experience as a confounding factor in comparing cochlear-implant processing schemes.

It is of great importance to compare the relative merits of different cochlear-implant speech-processing strategies. Some groups have compared different strategies within single subjects, but usually the subject has prior experience with one strategy, and no allowance is made for this prior experience. We show in the present study that this is inappropriate. We tested one subject using the Melbourne (Cochlear Corp.) multichannel implant with the device set to process sounds in two different ways. In the first processing scheme, the device functioned normally, extracting information about voicing frequency, amplitude and second-formant frequency. This information activated the 21-channel device, determining pulse rate, pulse amplitude and electrode position (respectively). In the second processing scheme, a single electrode (with the largest dynamic range) was activated. This electrode coded overall amplitude and voicing frequency. The subject was tested on an audiovisual test of a 14-choice consonant recognition in the form /iCi/ over a period of over 4 months. During this time the subject used the 21-channel processor outside of the laboratory. Upon initial connection, there was little difference between the results obtained with the two schemes when tested in sound alone or in sound plus vision. However, after about 4 months, scores obtained with the 21-channel processor in sound plus vision were superior to the scores obtained with the one channel. This advantage came from a superiority in the features of voicing and nasality, but not place. Scores for sound-alone conditions between the two processing schemes remained similar for the 4-month period.(ABSTRACT TRUNCATED AT 250 WORDS)

Auditory Threshold↗

Initial Iowa results with the multichannel cochlear implant from Melbourne.

Two subjects who use the Melbourne multichannel cochlear implant were studied. Live-voice word, consonant, and vowel recognition tests, and a speech-tracking task were administered at regular intervals during the first 90 days after implantation. Results indicated 30-50% correct recognition of vowels (given 9 alternatives) and about 30-60% correct recognition of consonants (given 12 alternatives). Speech tracking showed from two to three times faster rates with the implant and vision compared to a vision-alone condition. After 3-4 months of implant experience, a number of recorded tests from the Minimal Auditory Capabilities battery and the Iowa Cochlear-Implant tests were then administered. These results indicated about 80% recognition of everyday sounds in a five-choice closed-set condition and about 50% recognition of everyday sounds in an open-set condition. The subjects were 50% correct at identifying the accented words in a sentence and about 50% correct at determining the number of syllables in a word. One subject was unable to recognize a sentence as a statement or a question. Background noise (+10 dB S/N) reduced their performance on a four-choice spondee test to chance. Both subjects were able to identify a sound as either a voice or a modulated noise at 95% correct, and both could recognize speaker sex at 95% correct. Neither could discriminate whether two (successive) sentences were spoken by the same speaker or by two different speakers. Remarkably, one subject identified 45% and the other 85% of the words in sentences that were preceded by a contextual picture using sound alone. One subject identified 13% of the words in sentences in sound alone even without contextual information.

Adult↗

Preliminary assessment of the Los Angeles, Vienna and Melbourne cochlear implants.

We tested four patients using the single-channel cochlear implant from Los Angeles, three patients using the single-channel cochlear implant from Vienna, and two patients using the multichannel cochlear implant from Melbourne. Tests from the MAC battery and the Iowa Cochlear Implant Battery were used. Most patients were able to identify some environmental sounds. Three of the patients had difficulty distinguishing between male and female voices, and three could not distinguish between a noise and a voice. All patients had difficulty discriminating between unknown speakers of the same sex. A four-choice spondee test in noise showed that all patients suffered drastically from background noise. In all cases there was an improvement in lipreading ability with the implant. On a sentence test with a contextual cue seven patients got some words with sound alone. Results obtained with the multichannel implant are superior on several tasks, but we have tested too few patients to allow us any firm conclusions.

Auditory Perception↗

Audiological results with two single channel cochlear implants.

We tested six patients with single channel cochlear implants on several tests from the Minimal Auditory Capabilities battery and the Iowa Cochlear Implant Tests. All patients were able to discriminate some everyday sounds and to identify the number of syllables in the words presented. Five patients were able to identify speaker sex reliably. Surprisingly, some patients had difficulty discriminating between a modulated noise and a voice or between a question and a statement or identifying the accented word in a sentence. On several audiovisual tests, an improvement was observed for the sound plus vision condition compared to the vision only condition. This was particularly true for sentence tests, but was not uniform across patients or across tests.

Adult↗