PubMed Health⌕ Search

Biomedical subjects

J P Siebert

Publications and source records attributed to J P Siebert.

4 recordsLinked to original sources

Applications of 3D imaging in orthodontics: part I.

Part I of this paper describes the background, general concepts, available techniques and the clinical applications of recording external craniofacial morphology in three dimensions. Part II explores the different 3D techniques of imaging the dental arches, and their possible uses in orthodontic diagnosis and treatment.

Cephalometry↗

Validation of a vision-based, three-dimensional facial imaging system.

OBJECTIVE: The aim of this study was to assess the accuracy of a newly developed three-dimensional (3D) imaging system in recording facial morphology. METHODS: Twenty-one infants with cleft lip each had a full-face alginate impression taken at the time of primary lip repair, and a stone cast was constructed from each impression. Five anthropometric points were marked on each cast. Each cast was digitized, and the 3D co-ordinates of the five points were obtained using a co-ordinate measuring machine (CMM, Ferranti) of documented accuracy (9.53 microm). Each cast was scanned in four positions using a computerized stereophotogrammetry (C3D) system. The five points were located on the 3D images, and their 3D co-ordinates were extracted by three operators. The co-ordinate systems produced by C3D were aligned, via translation and rotation, to match the CMM co-ordinate system using partial ordinary procrustes analysis. The displacements of the adjusted C3D co-ordinates from the reference co-ordinates were then measured. Three different types of errors were identified: operator, system, and registration errors. RESULTS: Operator error was within 0.2 mm of the true co-ordinates of the landmarks. C3D was accurate within 0.4 mm. The average displacement of points over the 21 casts at four positions for the three operators was 0.79 mm (median 0.68). CONCLUSIONS: The presented 3D imaging system is reliable in recording facial deformity and could be utilized in recording cleft deformities and measuring the changes following surgery

Cephalometry↗

Visualization and model building in medical imaging.

We present technologies and ideas, developed from the JFIT 'Active Stereo Probe Project', which are applicable to problems within medical measurement and monitoring. Two related areas are considered. The first concerns patient body surface modelling. During the project two state-of-the-art non-contact surface measurement techniques have been developed which are applicable to medical situations requiring dense and accurate body surface modelling. Such applications include, for example, prosthetic appliance fabrication, presurgical planning and non-invasive deformity analysis. The second is concerned with overlay projection. Using this enabling technology the information content of a scene can be enhanced as an aid to medical personnel. Results and illustrative applications of the newly developed technology are presented.

Artificial Intelligence↗