PubMed Health⌕ Search

Biomedical subjects

J P Tasto

Publications and source records attributed to J P Tasto.

4 recordsLinked to original sources

Arthroscopic ankle arthrodesis.

The obvious socioeconomic advantages are quite dramatic, with early weight-bearing and AFO immobilization allowing patients an early return to work. Outpatient surgery is a cost-effective benefit. Patient satisfactions as well as comfort are greatly enhanced, requiring only oral pain medication. All patients have tolerated their postoperative regimen and same-day discharge. Arthroscopic subtalar arthrodesis is a technically demanding procedure that requires some rather advanced arthroscopic skills to perform. Joint access is tight, restricted, and requires small instrumentation. Deformities cannot be corrected; therefore, at this stage, a fusion in situ must be considered. The learning curve is certainly far steeper because of the smaller patient population available for enhancing surgical skills. Overall, this procedure has stood the test of time and follow-up. The results appear to be excellent in terms of patient satisfaction, fusion rate time until union, and postoperative morbidity. The recognition and enhancement of this technique as well as the development of more advanced technology will certainly allow this arthroscopic subtalar arthrodesis technique to mature even further over time.

Ankle Injuries↗

Current uses of radiofrequency in arthroscopic knee surgery.

Radiofrequency energy is a promising new technology in arthroscopy. Further basic science work is needed to define the mechanical characteristics of tissues in vivo at different times postoperatively. Long-term clinical follow-up studies are needed to determine the useful applications of this technology in the future.

Arthroscopy↗

Multiquadrant digital analysis of shoulder capsular thickness.

PURPOSE: Nonablative thermal capsular shrinkage has been developed in an attempt to address the plastic capsule deformation thought to cause increased rates of recurrent instability following arthroscopic stabilization procedures. Although the temperature required to optimize collagen shrinkage is known, a safe depth of thermal penetration, in various locations about the shoulder capsule, has not been defined. The purpose of this study was to measure shoulder capsule thickness by quadrant and circumferentially from the glenoid to the humerus so that thermal energy in shoulder procedures can be more precisely applied to limit possible injury to pericapsular structures. TYPE OF STUDY: This is an anatomic study using a cadaveric shoulder specimens. MATERIALS AND METHODS: Soft tissue was dissected from 8 fresh cadaveric shoulders to isolate intact glenohumeral joint capsules. The humeral insertion was released and the capsule was cut into 6 longitudinal quadrants around the glenoid. The capsule specimens were then flash frozen and stored at -80 degrees C. Quadrant tissue was cut into longitudinal sections 14 to 16 microm wide and stained with hematoxylin and eosin. The specimens were then digitized under a dissecting microscope and measured using computer imaging software at approximately 4-mm intervals. Two-way analysis of variance (ANOVA) was performed on the measurements of the intact capsule specimens 2.5 cm off the glenoid. Humeral insertion data were recorded separately. RESULTS: A total of 248 separate measurements were made throughout the capsule in 8 specimens. Capsular thickness increased from an average of 2.42 mm anteriorly to 2.80 mm in the inferior capsular pouch and again thinned to 2.22 mm posteriorly. Global shoulder capsule thickness ranged from 1.32 to 4.47 mm. When analyzed by position, from glenoid to humerus, a general thinning was noted with a mean thickness of 3. 03 mm at the glenoid to 2.17 mm at the humeral insertion. Two-way ANOVA showed a significant thickness variation along the specimen (P <.05), a nearly significant thickness variation with regard to quadrant (P <.03), and no significant interaction (P >.07) when applied to specimen measurements approximately 2.5 cm off the glenoid. CONCLUSIONS: The thickness of the shoulder capsule ranges from 1.32 to 4.47 mm, with a significant thinning laterally from the glenoid to the humerus. Further, capsule thickness ranges from 2.76 to 3.18 mm in the regions in closest proximity to the axillary nerve. These data may help determine the proper amount of thermal penetration necessary when performing shrinkage procedures and provide safety guidelines to limit the depth of thermal penetration to avoid possible injury to pericapsular structures.

Aged↗

Bioabsorbable implants in orthopaedics: new developments and clinical applications.

The use of bioabsorbable implants in orthopaedic surgical procedures is becoming more frequent. Advances in polymer science have allowed the production of implants with the mechanical strength necessary for such procedures. Bioabsorbable materials have been utilized for the fixation of fractures as well as for soft-tissue fixation. These implants offer the advantages of gradual load transfer to the healing tissue, reduced need for hardware removal, and radiolucency, which facilitates postoperative radiographic evaluation. Reported complications with the use of these materials include sterile sinus tract formation, osteolysis, synovitis, and hypertrophic fibrous encapsulation. Further study is required to determine the clinical situations in which these materials are of most benefit.

Absorbable Implants↗