Introduction: X-rays in chemistry.
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to J Penner-Hahn.
Explore the source record for details and available documents.
X-ray fluorescence spectroscopy is demonstrated here as a novel, element-specific detector for capillary electrophoresis. Monochromatic 10 keV X-rays from a synchrotron light source are used to excite core electrons, causing emission of characteristic Kalpha X-ray fluorescence (XRF) lines. Using this technique, XRF energies provide elemental identification, while XRF intensities can be used to quantitate the metal composition of each eluent. An X-ray transparent polymer coupling is used to create a window for the on-line, X-ray detection. This coupling contributes no measurable extra-column variance, and electrophoretic mobilities for the metal complexes used as model solutes are highly reproducible. The combination of XRF detection with capillary electrophoresis (CE-XRF) creates the first on-line detection system that is element-specific, nondestructive, and directly applicable to a broad range of applications including nonelectroactive species. CE-XRF is successfully demonstrated here for high binding-constant complexes of Fe(III), Co(II), Cu(II), and Zn(II). Within a single injection, electropherograms are obtained for each element of interest, with the element identity obtained directly from the emission energy. In contrast with ICPMS, this detection technique is directly on-line and does not require volatilization of the eluent. As a result, element-specific detection is not limited by the sample or the buffer volatility or atomization efficiency. Simultaneous XRF and UV absorbance detection can be used to provide an on-line determination of metal/chelate ratios. Although XRF detection limits are presently only in the 0.1 mM (0.5 ng) range, both collection geometry and incident intensity have yet to be optimized. Further optimization is expected to enhance this detection limit by another 2-3 orders of magnitude. As a result, the advent of XRF detection combined with the separating power of CE presents new possibilities for on-line, element-specific analysis.
The bacteriophage Mu Com protein is a small "zinc finger-like" protein that binds a specific site in com-mom operon mRNA and activates translation of the mom open-reading-frame. Com contains six cysteine and five histidine residues that have the potential to form several alternative zinc-finger-like motifs. We have used oligonucleotide site-directed mutagenesis to individually alter each of these amino acids (Cys to Ser, and His to Asn or Gln) and tested the various forms of Com for their ability to function in vivo. We observed that mutation of any one of the four N-terminal cysteine residues (Cys-6, 9, 26 or 29) resulted in loss of Com activity. The Com protein requires zinc in order to fold into its functional tertiary structure, as demonstrated by characteristic 1H nuclear magnetic resonance (NMR) chemical shifts. 1H chemical shifts revert to random coil values in the presence of the metal chelator EDTA. The metal-binding specificity and thermal stability of Com also has been investigated using 1H NMR. We report the use of 113Cd NMR, 1H-113Cd heteronuclear spin-echo difference spectroscopy HSED and Zn extended X-ray absorption fine structure spectroscopy EXAFS to determine the zinc/protein stoichiometry as 1:1 and the ligand environment as tetrathiolate. Comparative NMR spectra of Com mutants C6S and C39S suggest position 6 is involved in zinc coordination, while position 39 is not metal-liganded. These studies indicate that the metal coordination, site of Com is a four-cysteine complex, involving residues 6, 9, 26 and 29.
Per capita expenditure on pharmaceuticals is higher in Japan than in the US, despite a series of drug price reductions instigated by the Japanese Ministry of Health and Welfare that began in 1981. For some individual products, these price reductions cumulatively totalled more than 50%. This article argues that although the price of individual drugs is lower in Japan than in the US, aggregate expenditure is higher because of the greater use of newly-introduced original drugs and lower use of generics. Providers and consumers also tend to use drugs in larger quantities in Japan, because of polypharmacy and greater use of vitamins and nutrients, antihypertensives, cerebral metabolic activators (e.g. idebenone) and milder-acting drugs (i.e. drugs with low toxicity but unproven clinical efficacy). The level of expenditure is unlikely to decline, despite changes to pricing policy and ongoing efforts to improve the pharmaceutical distribution system and to discourage physician dispensing activities.