Ultra-high performance, solid-state, autoradiographic image digitization and analysis system.

We developed a Macintosh II-based, charge-coupled device (CCD), image digitization and analysis system for high-speed, high-resolution quantification of autoradiographic image data. A linear CCD array with 3,500 elements was attached to a precision drive assembly and mounted behind a high-uniformity lens. The drive assembly was used to sweep the array perpendicularly to its axis so that an entire 20 x 25-cm autoradiographic image-containing film could be digitized into 256 gray levels at 50-microns resolution in less than 30 sec. The scanner was interfaced to a Macintosh II computer through a specially constructed NuBus circuit board and software was developed for autoradiographic data analysis. The system was evaluated by scanning individual films multiple times, then measuring the variability of the digital data between the different scans. Image data were found to be virtually noise free. The coefficient of variation averaged less than 1%, a value significantly exceeding the accuracy of both high-speed, low-resolution, video camera (VC) systems and low-speed, high-resolution, rotating drum densitometers (RDD). Thus, the CCD scanner-Macintosh computer analysis system offers the advantage over VC systems of the ability to digitize entire films containing many autoradiograms, but with much greater speed and accuracy than achievable with RDD scanners.

Animals↗

Digital autoradiography: design, development, and evaluation of a solid-state image analyzer.

A digital image analyzer was developed for high spatial resolution analysis of autoradiograms. The system uses a linear array of charge-coupled devices operating under microcomputer control to scan and digitize autoradiograms into matrices of up to 1,500 X 2,000 pixels with 256 gray levels. The digitized images can be converted from gray scale to pseudo-color and displayed on a high resolution color monitor. Software was developed to facilitate quantitative analysis of autoradiograms produced in single and multiple tracer studies. Because of the high output linearity and accuracy of the solid-state detectors, the system was found to digitize autoradiograms significantly more precisely and accurately than previously described autoradiographic analyzers.

Autoradiography↗

High-performance digital image analyzer for quantitative autoradiography.

A digital image-processing system was developed for high-spatial resolution analysis of autoradiograms. The system uses a linear array of charge-coupled devices operating under computer control to scan and digitize autoradiograms into 512 X 512 matrices with 256 gray levels. Software was developed to facilitate quantitative analysis of autoradiograms produced in single- and multiple-tracer studies. Because of the high output, linearity, and accuracy of the solid-state detectors, the system was found to digitize autoradiograms significantly more precisely and accurately than previously described video camera- or photomultiplier tube-based scanning densitometers.