PubMed Health⌕ Search

Biomedical subjects

J Pochobradsky

Publications and source records attributed to J Pochobradsky.

3 recordsLinked to original sources

Actions of EGTA and high calcium on the cones in the turtle retina.

1. The effects of Ca2+ on the activity of retinal cones were investigated by recording intracellular responses from turtle retinae perfused with solutions containing different Ca2+ concentrations. 2. Lowering extracellular Ca2+ concentration with EGTA increased membrane conductance and evoked depolarization in darkness. 3. Responses to bright lights were increased by EGTA by an amount equal to the depolarization in darkness; responses to dim lights instead were usually reduced. In addition EGTA modified the time course of responses to flashes. These changes were especially evident during the later phases of the response. 4. A steady light applied during EGTA perfusion can restore the original membrane potential. The kinetics of responses in these conditions, however, differ profoundly from those prevailing Ca2+ concentrations evoked hyperpolarization of the cones and decreased the amplitude of their responses to bright lights. The time course of responses to flashes was not appreciably modified by high Ca2+. 6. A steady light which hyperpolarizes the cone membrane by the same amount as high Ca2+ has an equal effect on the amplitude of responses to bright flashes but has an entirely different action on response kinetics and on the amplitude of responses to dimmer flashes. 7. The effects of EGTA on resting potential, conductance and response amplitudecan be interpreted assuming that the drug opens channels which are normally closed by Ca2+ in darkness. Conversely, the changes caused by high Ca2+ suggest that raising the concentration of outside Ca2+ reduces the number of light-sensitive channels open in darkness. 8. The observation that Ca2+ and light have different effects on kinetics and sensitivities is difficult to reconcile with the hypothesis that Ca2+ is the substance liberated by light to cause photoresponses.

Animals↗

A new model for computerized clinical electron beam dosimetry.

Clinical electron beams consist of primary electrons, primary bremsstrahlung generated in the regular photon and electron collimator system determining the composite beam, and some short-range contaminant photon and electron scatter arising from the lower parts of the standard or regular electron applicator. Any beam-shaping insert placed inside the applicator causes some extra ("contaminant") bremsstrahlung and electron scatter. The new dose calculation model is based on separate treatment of these components. For the calculation of the primary electron dose we use experimentally determined electron scatter functions and differential electron scatter functions. The primary bremsstrahlung is treated as an unflattened but otherwise regular x-ray beam. The contaminant components arising from the rim area of the regular electron collimator and from beam-shaping inserts are considered separately. The behavior of the in-air ionization profiles is described using the concepts of effective electron source position and effective electron source diameter. The model has been tested for several electron energies.

Computer Simulation↗