Number of viable CD34(+) cells reinfused predicts engraftment in autologous hematopoietic stem cell transplantation.

Reduced CD34(+) cell viability due to cryopreservation has unknown effects on subsequent hematopoietic engraftment in autologous transplantation. Thirty-six consecutive autologous peripheral stem cell collections were analyzed for absolute viable CD34(+) cell numbers at the time of stem cell collection and prior to re-infusion. Viable CD34(+) cells were enumerated using single platform flow cytometry and the molecular exclusion dye 7-amino actinomycin D. The median number of viable CD34(+) cells was 3.6 x 10(6)/kg at the time of harvest and 2.0 x 10(6)/kg after thawing. When viable CD34(+)cells enumerated after thawing were <2.0, 2.0-5.0, or >5.0 x 10(6)/kg, the median time to platelet engraftment was 17, 12 and 10 days, respectively (P < 0.05 for comparison of the group with <2.0 x 10(6)/kg and the other two groups), and the median time to neutrophil engraftment was 13, 14 and 12 days, respectively (P = NS). A minimum of 2.0 x 10(6) CD34(+) cells/kg was harvested in 33 of 36 patients (92%) but only 19 of 36 (52%) patients met this threshold at the time of reinfusion. The reduced numbers of viable CD34(+) cells measured prior to re-infusion is associated with time to platelet engraftment and may be useful in monitoring stem cell loss during processing and identifying patients at risk of graft failure.

Adolescent↗

Comparison of PRE-dilatation vs direct stenting in coronary treatment using the Medtronic AVE S670 Coronary Stent System (the PREDICT trial).

Current stent delivery systems make primary stenting (stent placement without predilatation) possible, but few controlled trials have been performed to evaluate the success, safety, cost saving, and potential benefit of this approach in reducing late restenosis. The Comparison of PRE-Dilatation Versus Direct Stenting In Coronary Treatment using the Medtronic AVE S670 Coronary Stent System trial was a 399-patient study comparing results with the Medtronic-AVE S670 stent to objective performance criteria based on prior approved stents, with subrandomization to direct stenting versus stenting after balloon predilatation. Overall, results with the S670 stent showed excellent success and safety, with delivery success of 99%, a 14-day adverse event rate of 6.8% (including 6.5% non-Q-wave myocardial infarction), and favorable angiographic (20%) and clinical (12%) restenosis rates. Direct stenting was successful in 92% of cases, with a 99.5% secondary success rate including additional pretreatment of initially unsuccessful direct-stenting attempts, and no increase in complications. There were modest ( approximately 10%) savings in fluoroscopy time, contrast use, and a decrease in angioplasty balloon use (0.6 vs 1.3 balloons/case), but no reduction in clinical or angiographic restenosis. Patients treated later in the study, with a device that had less balloon extension beyond the edges of the stent, had slightly lower angiographic restenosis rates (19% vs 23%). In conclusion, the S670 stent showed excellent overall performance. Although direct stenting was safe and highly successful, it offered only modest cost savings, and no reduction in late restenosis compared with stenting after predilatation.

Catheterization↗

Comparison of self-expanding and balloon-expandable stents for the reduction of restenosis.

To compare the efficacy of self-expanding (SE) and balloon-expandable (BE) stents in native coronary arteries, we randomly assigned 1,096 patients with new and restenotic lesions to receive either device. Baseline demographics and coronary angiographic characteristics were similar in the 2 groups. The incidence of major adverse cardiac events including death, myocardial infarction, bypass surgery, and repeat intervention was similar for both groups at 1 month (2.9% vs 3.1% for SE vs BE, respectively) and at 9 months (19.3% vs 20.1%, SE vs BE respectively). In a subgroup of patients who underwent follow-up angiography (n = 250), the binary restenosis rates (24.2% vs 18.7%, p = 0.30), late loss (0.98 vs 94 mm, p = 0.60), and loss index (0.55 vs 55, p = 0.95) were not significantly different for both groups. In 62 patients who underwent intravascular ultrasound examination (IVUS), there was a trend toward a lower incidence of edge tears in the SE group (6% vs 23%, p = 0.06). Follow-up IVUS analysis showed that the minimum stent area of the SE stent increased by 33% at 6 months, whereas no change occurred in the BE stents; this was accompanied by a greater degree of intimal proliferation in the SE stents compared with BE stents (3.1 +/- 2.0 vs 1.7 +/- 1.7 mm(2)). Thus, the SE stents had similar clinical and angiographic outcomes in patients with lesions in native coronary arteries.

Angioplasty, Balloon, Coronary↗

The PARAGON stent study: a randomized trial of a new martensitic nitinol stent versus the Palmaz-Schatz stent for treatment of complex native coronary arterial lesions.

A new martensitic nitinol stent with improved flexibility and radiopacity was tested to evaluate whether these differences improve initial or long-term outcome. Patients who underwent percutaneous revascularization of a discrete native coronary lesion were randomly assigned to the new stent (PARAGON, n = 349) or to the first-generation Palmaz-Schatz (PS) stent (n = 339). The primary end point was target vessel failure at 6 months (a composite of cardiac or noncardiac death, any infarction in the distribution of the treated vessel, or clinically indicated target vessel revascularization). Secondary end points were, among others, device and procedural success and angiographic restenosis. Mean age was 62 years; diabetes was present in 21% of patients, prior bypass surgery in 6%, and recent infarction in 22% (p = NS for comparison between the 2 randomized arms). The PARAGON stent group had smaller reference vessels (2.97 vs 3.05 mm, p = 0.05), more prior restenosis (8.0% vs 4.5%, p = 0.07), and a longer average stent length (21.3 vs 19.4 mm, p < 0.05). Device success was significantly higher in the PARAGON arm (99.1% vs 94.3%, p < 0.05). Death and infarction at 6-month follow-up were infrequent in both groups. There was no significant difference in death (2.0% vs 1.2%, p = 0.546), but a higher rate of infarction for the PARAGON cohort (9.2% vs 4.7%, p = 0.025). Although target vessel failure (20.3% vs 12.4%, p = 0.005) and target lesion revascularization (12.0% vs 5.9%, p = 0.005) were higher in the PARAGON group, there was no significant difference in 6-month follow-up in in-stent minimal lumen diameter or in the rate of binary angiographic restenosis. Both PARAGON and PS stents are safe and associated with infrequent adverse events. The PARAGON stent can be delivered more frequently than the first-generation PS stent. Although there was no significant difference in in-stent minimal lumen diameter or the frequency of angiographic restenosis, clinical restenosis was more frequent in the PARAGON group.

Adult↗

Usefulness of stent length in predicting in-stent restenosis (the MULTI-LINK stent trials).

The cumulative experience of 4 clinical trials using the MULTI-LINK coronary stent design was analyzed. Multivariable logistic regression identified postprocedure in-stent minimum lumen diameter (p = 0.0001), stent length (p = 0.0038), smoking (p = 0.0105). and diabetes (p = 0.0803) as the most important predictors of in-stent restenosis at late (6- to 9-month) angiographic follow-up.

Adult↗

Low- versus high-dose recombinant urokinase for the treatment of chronic saphenous vein graft occlusion.

Recanalization of a totally occluded saphenous vein graft (SVG) using commercially available urokinase from human kidney cells has been shown to be effective, but the duration of infusion and complications such as allergic reactions, bleeding events, and non-Q-wave myocardial infarction have limited its acceptance. Recently, genetic engineering has allowed the synthesis of recombinant urokinase (r-UK). Patients with an occluded SVG from 37 centers were randomized to receive a 6-hour infusion of either low-dose (125,000 IU/hour) or high-dose (350,000 IU/hour) r-UK followed by up to a maximum of 18 hours of r-UK (125,000 IU/hour) via a subselective catheter directly into the occluded vein graft. The primary study end point was final preintervention achievement of Thrombolysis In Myocardial Infarction (TIMI) flow > or = 2 using core angiographic analysis. One hundred seven patients were randomized and 98 received the study drug (low dose 52 patients, high dose 46 patients). TIMI flow > or = 2 after completion of the study drug was higher in the high-dose group (51% vs 24%, p = 0.019). This difference narrowed, but a trend was still evident on the final angiogram after adjunctive mechanical intervention (72% vs 58%, p = 0.254). Bleeding complications were frequent; severe or life-threatening bleeding occurred in 12% of patients on the low dose and 11% of patients on the high dose (p = NS), including 2 intracerebral bleeds, both of which were fatal with 1 in each group. Thus, in patients with an occluded SVG, a randomized trial of direct low-dose versus high-dose r-UK infusion demonstrated increased recanalization rates (TIMI flow > or = 2) in the high-dose arm. Percutaneous revascularization of SVG with r-UK can be accomplished with acceptable success rates, but complications are frequent.

Adult↗

Single platform flow cytometric absolute CD34+ cell counts based on the ISHAGE guidelines. International Society of Hematotherapy and Graft Engineering.

In concert with the International Society of Hematotherapy and Graft Engineering (ISHAGE), we previously described a set of guidelines for detection of CD34+ cells based on a four-parameter flow cytometry method (CD45 FITC/CD34 PE staining, side and forward angle light scatter). With this procedure, an absolute CD34+ count is generated by incorporating the leukocyte count from an automated hematology analyser (two-platform method). In the present study, we modified the basic ISHAGE method with the addition of a known number of Flow-Count fluorospheres. To reduce errors inherent to sample washing/centrifugation, we implemented ammonium chloride lyse, no-wash no-fix sample processing. These modifications convert the basic protocol into a single-platform method to determine the absolute CD34 count directly from a flow cytometer and form the basis of the Stem-Kit from Coulter/Immunotech. A total of 72 samples of peripheral blood, apheresis packs, and cord blood were analysed and compared using the ISHAGE protocol with or without the addition of fluorescent microspheres. Comparison of methods showed a high correlation coefficient (r=0.99), with no statistically significant difference or bias between methods (P > 0.05). Linearity of the absolute counting method generated an R2 value of 1.00 over the range of 0-250/microl. Precision of the absolute counting method measured at three concentrations of CD34+-stabilised KG1 a cells (Stem-Trol, COULTER) generated a coefficient of variation (C.V.) ranging from 4% to 9.9%. In a further modification of the single-platform method, the viability dye 7-amino actinomycin D was included and demonstrated that both viable and nonviable CD34+ cells could be identified and quantitated. Together, these modifications combine the accuracy and sensitivity of the original ISHAGE method with the ability to produce an absolute count of viable CD34+ cells. It is the accurate determination of this value that is most clinically relevant in the transplant setting. These modifications may improve the interlaboratory reproducibility of CD34 determinations due to the reduction in sample handling and calculation of results.

Antigens, CD34↗

Laser wire for crossing chronic total occlusions: "learning phase" results from the U.S. TOTAL trial. Total Occlusion Trial With Angioplasty by Using a Laser Wire.

The Prima laser guidewire system (Spectranectics Corp., Colorado Springs, CO) consists of an 0.018" hypotube containing a bundle of 45-microm optical fibers coupled to a pulsed excimer laser operating at a tip fluence of 60 ml/mm2 and a repetition rate ranging from 25-40 Hz. This laser guidewire was specifically designed to cross total occlusions refractory to passage with conventional wires. The Prima wire was evaluated in a feasibility study at 15 U.S. centers. Following failure to cross a total occlusion with approved guidewires, the Prima wire was utilized in 179 patients. Average age of subjects was 61 yr. Lesion locations included left anterior descending (36%), right (45%), and circumflex (19%) coronary arteries. Mean angiographic age of total occlusions was 70 wk (range, 2-1,020 wk, median, 14 wk). The use of the Prima wire either solely or in combination with conventional guidewires resulted in successful crossing in 61% of these previously impenetrable occlusions. Failure of the device was commonly related to length of the occlusion and tortuosity along the occluded pathway. Major complications included myocardial infarction in 7 patients (3.9%), tamponade in 3 (1.7%), and death in 2 (1.1%). This "learning phase" pilot study confirmed the feasibility of a laser guidewire in chronic total occlusions that are resistant to passage of conventional guidewires. An extended registry at these investigative sites is planned.

Adult↗

Variability of radiation output dynamic range in modern cardiac catheterization imaging systems.

Automatic exposure control (AEC) is one of the most important characteristics for optimizing cardiac catheterization imaging; this allows the X-ray system to provide sufficient radiation output under a variety of clinical conditions so that a satisfactory image is obtained. AEC was assessed in 97 cardiac catheterization laboratories using a standard set of phantoms. Three different copper attenuators were used to simulate three patient sizes. As magnification increased, many systems had limited dynamic range and were unable to increase radiation output. With increasing atttenuator thickness, the problem worsened. With the thickest attenuator and largest magnification (4.5"-5.0" FOV), 60% of systems could not achieve the typical 70% increase in exposure while 20% were unable to increase radiation output at all.

Body Burden↗

Intracoronary Doppler assessment of moderate coronary artery disease: comparison with 201Tl imaging and coronary angiography. FACTS Study Group.

BACKGROUND: Coronary angiography may not reliably predict whether a stenosis causes exercise-induced ischemia. Intracoronary Doppler ultrasound may enhance diagnostic accuracy by providing a physiological assessment of stenosis severity. The goal of this study was to compare intracoronary Doppler ultrasound with both 201Tl imaging and coronary angiography. METHODS AND RESULTS: Fifty-five patients with 67 stenotic coronary arteries underwent coronary angiography with intracoronary Doppler ultrasound and had exercise 201Tl testing within a 1-week period. Coronary flow reserve was measured, and analyses were performed by independent core laboratories. The mean stenosis was 59+/-12%; 51 of 67 stenoses were intermediate in severity (40% to 70%). A coronary flow reserve < 1.7 predicted the presence of a stress 201Tl defect in 56 of 67 stenoses (agreement=84%; kappa=0.67; 95% CI=0.48 to 0.86). In the patients who achieved 75% of their predicted maximum heart rate, the Doppler and 201Tl imaging data agreed in 46 of 52 stenoses (agreement=88%; kappa=0.77; 95%CI=0.57 to 0.97). Scatter was evident when angiography was compared with coronary flow reserve (r=.43), and the angiogram did not reliably predict the results of the 201Tl stress test (kappa=0.21; agreement=57% to 63%). CONCLUSIONS: Doppler-derived coronary flow reserve accurately predicts the presence of exercise-induced ischemia on stress 201Tl imaging, and coronary angiography does not reliably assess the physiological significance of an intermediate coronary stenosis.

Aged↗

Coronary angioplasty of a posterolateral branch with severe proximal vessel tortuosity.

We present a case of a patient who experienced recurrent angina 15 months after coronary bypass surgery. A single lesion distal to a graft anastomosis was identified in the posterolateral coronary artery. There were two severe angulations, each greater than 90 degrees proximal to the lesion, with access possible only through the saphenous vein graft to the posterior descending artery. For ultimate success, such challenging anatomy required a combination of an array of guidewires, secondary support catheters, and a deflecting balloon.

Angina Pectoris↗

Comparison of thallium-201 SPECT redistribution patterns and rubidium-82 PET rest-stress myocardial blood flow imaging.

To compare regional thallium-201 SPECT redistribution patterns with rubidium-82 PET, we studied 81 patients with both imaging modalities. Sixty patients had significant coronary artery disease. All patients underwent PET imaging after dipyridamole infusion, while SPECT imaging was performed after exercise stress (38 patients) and dipyridamole (43 patients). Sixty-eight percent of patients with prior infarct had fixed defects on SPECT, compared to 39% with PET. Sixty-one percent of patients with prior infarct had PET perfusion defects which exhibited 'reflow' or normal rubidium-82 tracer uptake (p < 0.05 vs. SPECT). Similar results were seen in patients without prior infarct (26% fixed defects on SPECT vs. 12% for PET, p < 0.05). Regional analysis showed that 57% of fixed SPECT defects corresponded to PET defects with reflow or normal rubidium-82 uptake, while 78% of 'fixed' PET defects corresponded to fixed SPECT defects. PET reflow and normal rubidium-82 uptake in sites of fixed thallium-201 SPECT perfusion defects suggest that imaging modalities employing separate tracer injections at rest and after stress, such as rubidium-82 PET, may be more specific in the assessment of myocardial viability, especially in patients with prior myocardial infarction.

Aged↗

Baseline characteristics and therapeutic goals in the New Approaches to Coronary Intervention (NACI) registry.

BACKGROUND: The New Approaches to Coronary Intervention (NACI) voluntary registry was designed to study the use, safety, and efficacy of new percutaneous transluminal interventional devices including directional coronary atherectomy, the transluminal extraction catheter, the rotablator, the Palmaz-Schatz stent, the Gianturco-Roubin stent, the Advanced Interventional Systems (AIS) laser, and the spectranetics laser. METHODS: To date, more than 3800 consecutive patients treated for the first time with a new device at 41 centers have been entered into the registry. Complete detailed information about the patient, lesions, device characteristics, reasons for device selection, and procedural data, such as adjunctive use of conventional balloon angioplasty (PTCA), was available for the first 2835 patients. RESULTS: The registry shows that 88% of the 3233 attempts with a new device were intended as a definitive treatment of target lesions, frequently in combination with adjunctive PTCA. The remaining 12% of attempts with a new device were unplanned, prompted by unexpected complications, unsuccessful attempts, or suboptimal results with PTCA. Although there was some overlap in the indications for selecting a given interventional device, the variation from device to device was sufficiently large to caution users against any direct comparison of either safety or efficacy between devices without careful attention to the differences in baseline patient and lesion characteristics, treatment plans, and the circumstances of device use. CONCLUSION: This report provides the first comprehensive overview of how new interventional devices are currently being used in the treatment of coronary artery lesions at the 41 centers participating in the NACI registry.

Angina Pectoris↗

Comparison of rubidium-82 positron emission tomography and thallium-201 SPECT imaging for detection of coronary artery disease.

The diagnostic performance of rubidium-82 (Rb-82) positron emission tomography (PET) and thallium-201 (Tl-201) single-photon emission-computed tomography (SPECT) for detecting coronary artery disease was investigated in 81 patients (52 men, 29 women). PET studies using 60 mCi of Rb-82 were performed at baseline and after intravenous infusion of 0.56 mg/kg dipyridamole in conjunction with handgrip stress. Tl-201 SPECT was performed after dipyridamole-handgrip stress and, in a subset of patients, after treadmill exercise. Sensitivity, specificity and overall diagnostic accuracy were assessed using both visually and quantitatively interpreted coronary angiograms. The overall sensitivity, specificity and accuracy of PET for detection of coronary artery disease (greater than 50% diameter stenosis) were 84, 88 and 85%, respectively. In comparison, the performance of SPECT revealed a sensitivity of 84%, specificity of 53% (p less than 0.05 vs PET) and accuracy of 79%. Similar results were obtained using either visual or quantitative angiographic criteria for severity of coronary artery disease. In 43 patients without prior myocardial infarction, the sensitivity for detection of disease was 71 and 73%, respectively, similar for both PET and SPECT. There was no significant difference in diagnostic performance between imaging modalities when 2 different modes of stress (exercise treadmill vs intravenous dipyridamole plus handgrip) were used with SPECT imaging. Thus, Rb-82 PET provides improved specificity compared with Tl-201 SPECT for identifying coronary artery disease, most likely due to the higher photon energy of Rb-82 and attenuation correction provided by PET. However, post-test referral cannot be entirely excluded as a potential explanation for the lower specificity of Tl-201 SPECT.

Adult↗