Inhibition of ventricular stimulation in patients with dual chamber pacemakers and prolonged AV conduction.

Episodes of repetitive P wave undersensing have been described in dual chamber pacemakers due to automatic extension of the postventricular atrial refractory period (PVARP). Pacemaker stimulation was completely inhibited despite the presence of adequate P waves. This study sought to determine whether cycles of repetitive P wave undersensing occur even in the absence of PVARP extension. Two-hundred fifty-five patients were investigated after DDD or VDD pacemaker implantation for intermittent atrioventricular (AV) block. Forty-six episodes of repetitive atrial undersensing were found during 24-hour Holter ECG in nine patients. Pacemaker syndrome-like symptoms occurred. Episodes were elicited by atrial or ventricular premature contractions when (1) native AV conduction was present but considerably prolonged, (2) intrinsic sinus rate exceeded pacemaker intervention rate, and (3) native AV interval plus PVARP exceeded sinus cycle length. Programming of a particularly short AV interval and PVARP helped to reduce the incidence of repetitive P wave undersensing. Patients with dual chamber devices and prolonged native AV conduction are prone to develop episodes of output inhibition. Standard timing cycles may be inappropriate in these patients.

Atrioventricular Node

Diagnosis of atrial undersensing in dual chamber pacemakers: impact of autodiagnostic features.

Atrial undersensing occurs in a considerable number of patients, both with single lead VDD pacemakers and with DDD devices. The aim of this study was to investigate the diagnostic efficacy of electrocardiographic methods and autodiagnostic pacemaker features to detect atrial sensing dysfunction. Two hundred and thirty-one patients with AV block received single lead VDD pacemakers or DDD devices. Atrial sensitivity was programmed to 0.1 or 0.18 in VDD devices and to 0.5 mV in DDD devices; the rate limits were set to 40 and 160 beats/min. Twelve-lead ECG recording for 1 minute during deep respiration and change of body position, 24-hour Holter ECG recording, and treadmill exercise were performed 2 weeks and 15 months after pacemaker implantation. AV synchrony and, if available, P wave amplitude histogram were sampled by autodiagnostic pacemaker features and compared to electrocardiographic findings. Atrial undersensing was assumed, if AV synchrony was below 100% or if minimal P wave amplitude (PWA) was equal to the programmed atrial sensitivity. Intermittent atrial undersensing occurred in 20.7% of patients. The diagnostic sensitivities of the various methods used to detect atrial sensing failures were: 24-hour Holter monitoring 97.5%, P wave amplitude histogram 90.0%, stored AV synchrony 68.0% without significant difference between the various devices, treadmill exercise testing 58.8%, and 12-lead ECG recording 21.3%. In one patient, atrial undersensing was exclusively detected by exercise testing. In conclusion, autodiagnostic pacemaker features facilitate the evaluation of atrial sensing performance. However, to exclude intermittent atrial malesensing, routine Holter monitoring and treadmill exercise are still needed.

Aged

Electrophysiological performance of a bipolar membrane-coated titanium nitride electrode: a randomized comparison of steroid and nonsteroid lead designs.

The aim of this multicenter study was to investigate the performance of a new cardiac pacemaker lead with a titanium nitride cathode coated with a copolymer membrane. In particular, the electrophysiological effect of steroid dissolved in this ion-exchange membrane was evaluated by randomized comparison. Ninety-five patients were randomized either to the 1450 T (n = 51) or the 1451 T ventricular lead (n = 45) and received telemeteral VVI(R) pacemakers with identical diagnostic features. Both leads were bipolar, were passively affixed, and had a porous titanium nitride tip with a surface area of 3.5 mm2. The only difference between the two electrodes was 13 micrograms of dexamethasone added to the 1450 Ts membrane coating. Voltage thresholds (VTH) at pulse durations of 0.25, 0.37, and 0.5 ms, lead impedance, and sensing thresholds were measured at discharge, 2 weeks, 1 month, 3 months, and 6 months after implantation. Mean amplitude and the slew rate from three telemetered intracardiac electrograms, chronaxie-rheobase product, and minimum energy consumption were calculated. After a 6-month follow-up, mean voltage thresholds of 0.65 +/- 0.20 V and 0.63 +/- 0.34 were achieved for the 1450 T lead and 1451 T lead, respectively. As a result, a VTH < 1.0 V was obtained in all patients with 1450 T electrodes and in 97.7% of patients with 1451 T leads after 6 months follow-up. In both electrodes, stable VTH was reached 2 weeks after implantation, and no transient rise in threshold was observed. No differences were observed between the steroid and the nonsteroid group in respect to VTH, chronaxie-rheobase product, minimum energy consumption, and potential amplitude and slew rate. In conclusion, safe and efficient pacing at low pulse amplitudes were achieved with both leads. The tip design, independently of the steroid additive, prevented any energy-consuming increases in the voltage threshold.

Coated Materials, Biocompatible

Atrial sensing and AV synchrony in single lead VDD pacemakers: a prospective comparison to DDD devices with bipolar atrial leads.

INTRODUCTION: Single lead VDD pacing has offered an alternative to DDD systems in patients with isolated AV block. Up to now, however, the relative performance of these pacemaker systems was not systematically compared. METHODS AND RESULTS: Three hundred sixty patients who received either a VDD pacemaker (n = 180) or a DDD device (n = 180) with a bipolar atrial lead were investigated prospectively for a mean period of 30 +/- 13 months. Pacemaker function was analyzed by telemetry, Holter monitoring, and exercise ECG. Time of implantation and fluoroscopy was significantly lower with VDD devices (44.3 +/- 5.1 min vs 74.4 +/- 13.5 min and 4.6 +/- 2.5 min vs 10.3 +/- 5.6 min in DDD pacemakers, respectively). Intermittent atrial undersensing occurred in 23.3% of patients with a VDD pacemaker and in 9.4% with DDD devices (NS). The incidence of atrial tachyarrhythmias did not differ between the VDD (6.7%) and the DDD group (6.1%). Sinus node dysfunction developed in 1.9% of patients, but the vast majority (85.7%) of patients were asymptomatic. There was a tendency for a higher rate of operative revisions in the DDD group (6.1% vs 3.3% in VDD pacemakers, P = 0.15). Cumulative maintenance of AV-synchronized pacing mode was 94.9% in patients with VDD pacemakers and 92.1% with DDD devices (NS). CONCLUSION: With the benefit of a simpler implant procedure, long-term outcome of single lead VDD pacing is equivalent to DDD pacing in patients with AV block and preoperative normal sinus node function.

Aged

Development of sinus node disease in patients with AV block: implications for single lead VDD pacing.

OBJECTIVE: To investigate the incidence of sinus node disease after pacemaker implantation for exclusive atrioventricular (AV) block. DESIGN: 441 patients were followed after VDD (n = 219) or DDD pacemaker (n = 222) implantation for AV block over a mean period of 37 months. Sinus node disease and atrial arrhythmias had been excluded by Holter monitoring and treadmill exercise preoperatively in 286 patients (group A). In 155 patients with complete AV block, a sinus rate above 70 beats/min was required for inclusion in the study (group B). Holter monitoring and treadmill exercise were performed two weeks, three months, and every six months after implantation. Sinus bradycardia below 40 beats/min, sinoatrial block, sinus arrest, or subnormal increase of heart rate during treadmill exercise were defined as sinus node dysfunction. RESULTS: Cumulative incidence of sinus node disease was 0.65% per year without differences between groups. Clinical indicators of sinus node dysfunction were sinus bradycardia below 40 beats/min in six patients (1.4%), intermittent sinoatrial block in two (0.5%), and chronotropic incompetence in five patients (1.1%). Only one of these patients (0.2%) was symptomatic. Cumulative incidence of atrial fibrillation was 2.0% per year, independent of the method used for the assessment of sinus node function and of the implanted device. CONCLUSIONS: In patients undergoing pacemaker implantation for isolated AV block, sinus node syndrome rarely occurs during follow up. Thus single lead VDD pacing can safely be performed in these patients.

Aged

Relation between QT dispersion and the extent of myocardial ischemia in patients with three-vessel coronary artery disease.

The aim of the study was to examine the relation between the extent of myocardial ischemia and changes in QT interval dispersion in patients with obstructive coronary artery disease and in patients with normal coronary arteries. QT interval dispersion reflects regional variations in ventricular repolarization and cardiac electrical instability. Previous studies showed QT interval dispersion changes during episodes of myocardial ischemia in patients with coronary artery disease, but no data on the relation between extent of myocardial ischemia and degree of QT interval dispersion changes are available. To assess the effects of myocardial ischemia on myocardial repolarization by analyzing the change in QT dispersion during incremental atrial pacing, we studied 33 patients (7 women and 26 men, mean age 60.1 +/- 5.1 years, 18 patients with normal coronary arteries, 15 patients with coronary 3-vessel disease). QT dispersion was measured at baseline, after each pacing period, within 30 seconds after cessation of pacing ("peak ischemic stress"), and at 1-minute intervals for up to 5 minutes. Paired blood samples for determination of serum lactate were withdrawn from the coronary sinus and radial artery to determine the cardiac lactate extraction ratio at each point of electrocardiographic registration. In patients with coronary artery disease, QT dispersion increased from a baseline value of 39 +/- 7 ms to a peak ischemic stress value of 63 +/- 10 ms (p <0.0001). Patients with normal coronary arteries showed almost unchanged values of QT dispersion (41 +/- 9 vs 42 +/- 7 ms). There was a significant relation between the pacing-induced change in QT dispersion and the induced change in myocardial lactate extraction ratio (r = 0.76, p <0.0001). The change in QT dispersion (baseline vs peak pacing stress) was related to the extent of the cardiac lactate extraction ratio (r = -0.79, p <0.0001). These data indicate that the severity or extent of induced myocardial ischemia was related to the degree of induced changes of the variability in the timing of the ventricular recovery pattern.

Aged

Myocardial ischemia in generalized coronary artery-left ventricular microfistulae.

Generalized (multiple) arterio-systemic fistulae are fistulae arising from all three major coronary arteries and drain into the left ventricle are rare and the clinical and hemodynamic sequelae are incompletely understood. This communication is based on the clinical and hemodynamic data of a series of patients (eight cases out of 7262 consecutive patients) incidentally identified at coronary angiography combined with data from cases previously reported in literature. The aim was to assess the role of generalized coronary artery fistulae as a non-atherosclerotic cause of myocardial ischemia by means of a coronary sinus lactate study. Coronary sinus lactate study demonstrated myocardial ischemia in 6/7 patients. Mean arterio-coronary venous lactate difference decreased from 0.31+/-0.18 mmol/l (lactate extraction ratio, LER, 29.4+/-13.9%) at rest to 0.04+/-0.13 mmol/l (LER -4.0+/-13.3%) at peak exercise. Five minutes after cessation of pacing, lactate difference increased to 0.22+/-0.21 mmol/l (LER -20.7+/- 13.2%). At peak pacing stress, 4/7 patients showed frank lactate production, and two patients presented with a reduced cardiac lactate extraction rate also indicating myocardial ischemia metabolically. In the present study, we demonstrated a possible role of a coronary steal mechanism due to microfistulae pathways in the pathogenesis of myocardial ischemia in patients with generalized coronary artery-left ventricular microfistulae.

Aged

An optimized AV delay algorithm for patients with intermittent atrioventricular conduction.

Detection and promotion of an intermittent atrioventricular (AV) conduction is the objective of an AV delay hysteresis algorithm in dual chamber pacemaker (DDD) pacing. The AV delay following an atrial event is automatically extended by a programmable interval (AV hysteresis interval) if the previous cycle showed spontaneous AV conduction, i.e., a ventricular event was detected within the previous AV delay. An automatic search mode scans for spontaneous ventricular events during the hysteresis interval: a single AV delay extension (equal to the programmed AV delay hysteresis) will occur after a successive, programmable number of AV cycles with ventricular pacing. If a spontaneous AV conduction is present, the AV delay will remain extended by the hysteresis interval. Our first results in 17 patients with intermittent AV block disclosed a satisfactorily working algorithm with effective reduction of ventricular stimuli. In relation to the underlying conduction disturbance and pacemaker settings, the majority of our patients showed a reduction of ventricular pacing events up to 90% without any adverse hemodynamic or electrophysiological changes. Based on clinical (promotion of a physiological activation and contraction sequence) and technical (reduction of power consumption) advantages, the AV hysteresis principle could be of incremental value for future dual chamber pacing in patients with intermittent complete heart block.

Aged

Should unipolar leads be implanted in the atrium? A Holter electrocardiographic comparison of threshold adapted unipolar and high sensitive bipolar sensing.

The accuracy of atrial sensing plays a central role in dual chamber pacing. Recent Holter electrocardiographic studies showed a high incidence of atrial malsensing. We investigated the efficacy of bipolar atrial sensing at high sensitivity compared to threshold adapted unipolar sensing. One hundred consecutive patients with identical dual chamber pacemakers and bipolar atrial leads were investigated. Mean and individual range of 40 unipolar and bipolar telemetered atrial potentials were calculated; sensing threshold was determined by a semiautomatic sensing test. Oversensing was investigated with the help of a muscle provocation test. Twenty-four-hour Holter monitoring was performed at the highest bipolar sensitivity as well as at a unipolar sensitivity of half the measured sensing threshold. Mean atrial potential was significantly lower during bipolar mode compared to the unipolar sensing configuration, 3.66 +/- 1.75 versus 3.85 +/- 1.62 mV, P = 0.02. The bipolar atrial potentials showed a higher individual range than the unipolar signals, 2.44 +/- 2.62 versus 1.79 +/- 0.92 mV, P < 0.01. Sensing threshold did not differ significantly, 2.76 +/- 1.33 versus 2.67 +/- 1.29 mV. Mean oversensing threshold was 1.21 mV at unipolar configuration, whereas oversensing could not be provoked at a bipolar sensitivity of 0.5 mV. The incidence of atrial undersensing was significantly higher at threshold adapted unipolar sensing compared to bipolar sensing at highest atrial sensitivity, 35% versus 22%, P = 0.04. Oversensing did not occur at bipolar sensing, but was observed in 56% of patients at unipolar mode. Thirty-two percent of patients showed both atrial undersensing and oversensing at the unipolar sensing configuration. The muscle provocation test reached a sensitivity of 89% and a specificity of 95% in prediction of atrial oversensing during daily life. In conclusion, unipolar atrial potentials are more stable than bipolar ones. On the other hand, bipolar atrial sensing is less prone to the perception of myopotentials. Programming a high bipolar sensitivity significantly improves atrial sensing. Thus, bipolar leads should generally be implanted in the atrium.

Aged

Neutrophil-derived oxidative stress after myocardial ischemia induced by incremental atrial pacing.

We studied the effect of atrial pacing-induced myocardial ischemia on the generation of oxygen free radicals (OFR) in 8 patients with verified coronary artery disease (CAD) and in a control group of 4 patients without coronary atherosclerosis. Myocardial ischemia was measured metabolically by simultaneous lactate sampling from coronary sinus (CS) and arterial blood. Generation of OFR from purified viable polymorphonuclear neutrophils (PMN) was assessed by means of the chemiluminescence (CL) method. At peak pacing, 7 of 8 patients with CAD exhibited transient myocardial ischemia (mean lactate extraction ratio at rest: 23.6 +/- 7.7 vs 5.21 +/- 5.1% at peak pacing, p = 0.012). In these patients, unstimulated PMN harvested from the CS depicted a significant increase of luminol-enhanced CL (from 1.06 +/- 0.54 to 2.15 +/- 1.28 cpm x 10(5), p = 0.012) after atrial pacing. There was no additional effect from further ex vivo stimulation with phorbol myristate acetate. This finding underscores the role of myocardial ischemia as a potent endogenous activator of PMN function and may have implications in the pathogenesis and progression of atherosclerosis.

Cardiac Pacing, Artificial

Differential effects of defibrillation on systemic and cardiac sympathetic activity.

OBJECTIVE: To assess the effect of defibrillation shocks on cardiac and circulating catecholamines. DESIGN: Prospective examination of myocardial catecholamine balance during dc shock by simultaneous determination of arterial and coronary sinus plasma concentrations. Internal countershocks (10-34 J) were applied in 30 patients after initiation of ventricular fibrillation for a routine implantable cardioverter defibrillator test. Another 10 patients were externally cardioverted (50-360 J) for atrial fibrillation. MAIN OUTCOME MEASURES: Transcardiac noradrenaline, adrenaline, and lactate gradients immediately after the shock. RESULTS: After internal shock, arterial noradrenaline increased from a mean (SD) of 263 (128) pg/ml at baseline to 370 (148) pg/ml (p = 0.001), while coronary sinus noradrenaline fell from 448 (292) to 363 (216) pg/ml (p = 0.01), reflecting a shift from cardiac net release to net uptake. After external shock delivery, there was a similar increase in arterial noradrenaline, from 260 (112) to 459 (200) pg/ml (p = 0.03), while coronary sinus noradrenaline remained unchanged. Systemic adrenaline increased 11-fold after external shock (p = 0.01), outlasting the threefold rise following internal shock (p = 0.001). In both groups, a negative transmyocardial adrenaline gradient at baseline decreased further, indicating enhanced myocardial uptake. Cardiac lactate production occurred after ventricular fibrillation and internal shock, but not after external cardioversion, so the neurohumoral changes resulted from the defibrillation process and not from alterations in oxidative metabolism. CONCLUSIONS: A dc shock induces marked systemic sympathoadrenal and sympathoneuronal activation, but attenuates cardiac sympathetic activity. This might promote the transient myocardial depression observed after electrical discharge to the heart.

Adult

Cardiomyopathic lentiginosis/LEOPARD syndrome presenting as sudden cardiac arrest.

A 26-year-old apparently healthy man with numerous pigmented skin lesions collapsed during an evening party and was resuscitated from ventricular fibrillation. Hypertrophic cardiomyopathy and subaortic tunnel were disclosed by angiocardiography. A diagnosis of cardiomyopathic lentiginosis/lentigines (multiple), electrocardiographic abnormalities, ocular hypertelorism, pulmonary stenosis, abnormalities of the genitalia, retardation of growth, and deafness (sensorineural) syndrome was made. The patient then underwent treatment with an implantable pacer-cardioverter-defibrillator device. Further evaluation revealed several well-established features of the disorder. This is the first reported case of survival from ventricular fibrillation associated with this rare and little known multifaceted syndrome. Disseminated lentiginosis must prompt clinicians to evaluate such cases further since underlying disorders may be associated with considerable morbidity and, apparently, sudden death.

Abnormalities, Multiple

Priming of neutrophils after elective percutaneous transluminal coronary angioplasty is unrelated to accompanying brief myocardial ischemia.

OBJECTIVE: The purpose of this study was to investigate the effect of brief myocardial ischemia and vascular trauma induced by elective percutaneous transluminal coronary angioplasty on in vivo 'priming' and activation of neutrophils. PATIENTS AND METHODS: We studied 16 patients undergoing elective coronary angioplasty for symptomatic coronary artery disease and a control group of seven patients undergoing diagnostic cardiac catheterization. Free radical production from purified neutrophils (Ficoll-Hypaque density gradient method) was measured indirectly by the chemiluminescence method. Myocardial ischemia during balloon inflation was assessed by serial lactate determinations from coronary sinus and arterial blood. The degree of transient angioplasty-related myocardial ischemia was related to the oxidative response of activated neutrophils. RESULTS: Mean (+/-S.E.M.) oxidative response, i.e. the lucigenin- and luminol-enhanced-chemiluminescence (counts per minute) of neutrophils sampled from the coronary sinus increased significantly after percutaneous transluminal coronary angioplasty (Lucigenin-chemiluminescence: pre-angioplasty 3.69+/-0.64x10(5) vs. post-angioplasty 7.08+/-1.2x10(5), P<0.01; Luminol-chemiluminescence: pre-angioplasty 2.81+/-0.67x10(6) vs. post-angioplasty 5.2+/-0.92x10(6), P<0.01). Twelve of 16 patients developed transient cardiac lactate production (mean coronary sinus lactate excess: +0.12 mmol/l) and three disclosed a lactate extraction ratio <10%, both suggestive of myocardial ischemia. However, there was no correlation between the cardiac lactate production and the increased oxidative response after coronary angioplasty (r2 (Lucigenin-chemiluminescence)=0.02, n.s.; r2 (Luminol-chemiluminescence)=0.06, n.s.). CONCLUSION: 'Priming' of neutrophils, as reflected by increased oxidative response, is likely to occur after coronary angioplasty, but not after the angiographic procedure itself. However, 'priming' seems to be unrelated to the transient brief period of myocardial ischemia and rather depends on an alternative mechanism.

Adult

[Atrial sensing and atrioventricular synchrony in single lead VDD pacemakers. Can the appearance of atrial undersensing be predicted?].

Single-lead VDD-pacing is an alternative to DDD-systems in patients with AV-block and normal sinus node function. Atrial sensing plays a central role in these pacemakers. AV-synchrony, incidence of atrial arrhythmias and the occurrence of sinus node disease were investigated in 108 patients with VDD-pacemakers followed over a mean period of 24.8 months after implantation. Determinants influencing the occurrence of atrial undersensing were especially focused on. Mean atrial potential and sensing threshold were reduced within the first 2 weeks after implantation (p < 0.01). Intermittent atrial undersensing occurred in 25.9% of patients and was observed in 82.1% of these patients within the first 2 weeks after implantation. Positioning the atrial dipole in the low right atrium showed a significantly higher incidence of atrial undersensing (42% in comparison to 24% in the other positions). In a multivariate analysis including intra- and postoperative measurements as well as characteristics of the pacemakers and leads, it was the only parameter significantly (p < 0.02) correlated to the occurrence of atrial undersensing. Atrial fibrillation was observed in 4.6% of patients, a sinus node disease became evident in 2.7% of patients; 92.6% of patients remained in the AV-synchronous mode. Intermittent atrial undersensing is common in single-lead VDD-pacemakers and difficult to provide during implantation. The atrial dipole should not be positioned in the low right atrium and highest atrial sensitivity should generally be programmed. Nevertheless, VDD-pacing achieves an AV-synchrony comparable to DDD-pacemakers.

Aged

Impact of early accelerated dose tissue plasminogen activator on in-hospital patency of the infarcted vessel in patients with acute right ventricular infarction.

OBJECTIVE: To assess the efficacy of early accelerated dose tissue plasminogen activator on in-hospital patency of the infarct related artery in patients with inferior myocardial infarction with and without right ventricular involvement. DESIGN: Single centre prospective assessment before discharge of infarct related vessel patency after early thrombolysis. SETTING: Tertiary cardiac referral centre at a university hospital. PATIENTS AND METHODS: 90 consecutive unselected patients with acute myocardial infarction, of whom 35 (39%) had electro-cardiographic evidence of right ventricular involvement (ST segment elevation greater than 0.1 mV in right precordial lead V4R), were studied. All patients received accelerated dose tissue plasminogen activator 100 mg within six hours from the onset of symptoms and had control angiography before discharge. MAIN OUTCOME MEASURES: Infarct related coronary artery patency using the Thrombolysis in Myocardial Infarction (TIMI) grading system before discharge. Incidence of prolonged systemic hypotension, sinus bradycardia, complete atrioventricular block, and ventricular tachyarrhythmia during early hospitalisation. RESULTS: Despite aspirin and bolus heparinisation before thrombolysis and high dose heparinisation thereafter for at least 48 hours the infarct related artery was more likely to be occluded (TIMI 0 or 1 flow) in patients with right ventricular involvement than in those without (69 v 29%, P < 0.001), as shown by control angiography performed a mean of 12.8 days after thrombolysis. These findings may be explained, at least in part, by predominant involvement of the proximal right coronary artery (66 v 31%, P < 0.05) and a low cardiac output syndrome, being indirectly reflected by a high incidence of prolonged hypotension (26 v 7%, P = 0.02), bradycardia (34 v 14%, P = 0.03), and complete atrioventricular block (37 v 5%, P = 0.0001). CONCLUSION: Primary angioplasty should be considered as the treatment of choice in patients with acute inferior infarction with right ventricular involvement because of the high failure rate of thrombolysis.

Coronary Angiography

Electrophysiological characteristics of bipolar membrane carbon leads with and without steroid elution compared with a conventional carbon and a steroid-eluting platinum lead.

In a controlled study, the following four bipolar leads with passive fixation were implanted in 46 patients with the Siemens-Multilog-VVI or Sensolog-VVIR-pacemakers: membrane covered activated porous carbon with steroid elution (Siemens 1402 T, 11 patients) and without (Siemens 1403 T, 15 patients); activated carbon (Siemens 1010 T, 10 patients); and platinum with steroid elution (Medtronic Cap-Sure 5026, 10 patients). Stimulation threshold (STH) (assessed by a vario-test), impedance (IMP), and the intracardial R wave potential (IRW) (both gauged by a telemetric method) were measured 1, 5, and 10 days as well as 3 and 6 months after implantation during unipolar and bipolar stimulation, chronaxie rheobase product (CRP) and energy consumption (EC) were systematically determined. Differing insignificantly at the first day after implantation, STH is significantly lower for the 1402 T and CapSure 5026 leads at the tenth day. However, the 1402 T lead shows a significant increase of STH in the follow-up, in contrast to the other leads. The lowest chronic STH was found in the CapSure 5026 lead (CRP is significantly lower in all other leads, too). IMP is significantly lower in the CapSure 5026 lead compared to 1010 T lead. EC does not differ significantly during chronic stimulation in spite of the best possible programming of pulse amplitude and duration. No significant changes of IRW were observed. Unipolar versus bipolar stimulation shows significantly lower STH, CRP, and IMP, differences of EC and IRW were insignificant. In conclusion, the addition of steroid in membrane covered carbon leads protracts the increase of STH, but does not prevent it. The CapSure 5026 lead shows advantageous stimulation characteristics, but energy consumption is not significantly reduced because of low impedance and impossibility of programming an appropriate low output in Multilog pacemakers.

Aged

Accelerated ST-segment reduction after thrombolytic therapy with recombinant tissue plasminogen activator (rtPA) compared to urokinase.

Effects of therapy with urokinase (UK) and with recombinant tissue plasminogen activator (rtPA) were compared in patients with acute myocardial infarction (AMI). To achieve homogenous therapeutic conditions the comparison was restricted to patients having their first AMI and to cases of clinically successful thrombolytic therapy (defined by non-invasive criteria, such as a 50% decrease in elevated ST-segment in the worst load of a 12 lead ECG within 300 min after onset of thrombolytic therapy, complete pain resolution during thrombolytic therapy, and later confirmed by angiography 10 days after AMI). Effects of UK and rtPA on continuous multilead ST-segment analysis and cardiac proteins (creatine kinase and its isoenzyme CK-MB, aspartate transaminase and hydroxybutyrate dehydrogenase) were analyzed during 24 hours following onset of therapy. Continuous ST analysis showed a faster resolution of the elevated ST-segments after thrombolytic therapy with rtPA than with UK(p < 0.01). Accelerated idioventricular rhythms (p < 0.05) occurred sooner following rtPA than UK treatment. The wash-out of creatine kinase was increased (p < 0.01) after rtPA. Although both drugs induced comparable, angiographically controlled reperfusion, the results suggest that the process of reperfusion was accelerated during thrombolysis with rtPA compared to UK. Thrombolytic therapy of AMI with rtPA may hence improve myocardial salvage.

Adult

[Detection of stress-induced myocardial ischemia in isolated coronary ectasia and aneurysm (dilatative coronaropathy)].

Forty eight patients with bilateral isolated non-stenotic coronary artery ectasia or aneurysm without associated cardiac defects ("dilated coronaropathy") were identified in consecutive diagnostic cardiac catheterizations between 1986-6/1994 (angiographic incidence 0.44%). Ectasia was defined as a luminal dilatation of the 1.5-2-fold, aneurysm of more than double the normal limits. In 16 patients a myocardial infarction (5 non-q-infarctions/11 q-wave-infarctions) was the indication for coronary angiography, a thrombotic occlusion of the infarct vessel was documented in 8/16 patients. In patients without myocardial infarction (study group) an evaluation of exercise-induced myocardial ischemia was performed by means of a coronary sinus lactate study, treadmill ergometry and Thallium-201-scintigraphy. A corresponding coronary insufficiency was objective in all tests in the study group. An exercise-induced myocardial ischemia was found in 21/31 in the coronary sinus study, 19/29 in the treadmill ergometry and 13/26 patients in the scintigraphy; significant differences were found in comparison to the results of a control group of patients without heart disease (n = 29, p < 0.001). After administration of 0.8 mg nitroglycerin (NTG) a further significant deterioration of myocardial ischemia was measured in the 21 patients with pathologic lactate metabolism developing a frank cardiac lactate production (p < 0.03). The extent of myocardial ischemia in the coronary sinus study was significantly correlated to the coronary diameters of the proximal and middle segments of the Ramus interventricularis anterior and the middle segment of the Ramus circumflexus (r = 0.87, p < 0.02). A differentiation between ectasia and aneurysm therefore seems to be of functional relevance. Angiographic stigmata of an impaired coronary blood flow such as a segmental to and from movement and a local deposition of dye were found significantly more often with increasing coronary diameters (p < 0.04). "Dilated coronaropathy" is an entity of non-stenotic, ischemic coronary artery disease. NTG was of no therapeutic benefit or led to an aggravation of the exercise-induced myocardial ischemia. Because of this potential adverse effect the administration of NTG should be avoided in "dilated coronaropathy".

Adult