PubMed Health⌕ Search

Biomedical subjects

J Pouliot

Publications and source records attributed to J Pouliot.

At least 19 recordsLinked to original sources

The use of megavoltage cone-beam CT to complement CT for target definition in pelvic radiotherapy in the presence of hip replacement.

In Europe and the USA combined, over half a million people had a hip joint replaced in 2005, contributing to the increasing number of radiotherapy patients with metallic hip prostheses. The treatment plan for external beam radiation therapy is based on the delineation of the anatomy in the planning CT scan. When implanted objects of high atomic number (Z) material are present, however, severe image artefacts are generated in conventional CT, strongly hindering the ability to delineate some organs. This is particularly the case for the planning of prostate patients with hip prostheses. This short communication presents the use of a new imaging modality, megavoltage cone-beam CT, to complement the regular CT for target definition of prostate cancer treatment of patients with hip replacements.

Hip Prosthesis↗

[Megavoltage cone-beam CT: Recent developments and clinical applications].

The Megavoltage cone-beam (MV CBCT) system consists of a new a-Si flat panel adapted for MV imaging and an integrated workflow application allowing the automatic acquisition of projection images, cone-beam CT image reconstruction, CT to CBCT image registration and couch position adjustment. This provides a 3D patient anatomy volume in the actual treatment position, relative to the treatment isocenter, moments before the dose delivery, that can be tightly aligned to the planning CT, allowing verification and correction of the patient position, detection of anatomical changes and dose calculation. In this paper, we present the main advantages and performance of this MV CBCT system and summarize the different clinical applications. Examples of the image-guided treatment process from the acquisition of the MV CBCT scan to the correction of the couch position and dose delivery will be presented for spinal and lung lesions and for head and neck, and prostate cancers.

Head and Neck Neoplasms↗

Dose-guided radiation therapy with megavoltage cone-beam CT.

Recent advances in fractionated external beam radiation therapy have increased our ability to deliver radiation doses that conform more tightly to the tumour volume. The steeper dose gradients delivered in these treatments make it increasingly important to set precisely the positions of the patient and the internal organs. For this reason, considerable research now focuses on methods using three-dimensional images of the patient on the treatment table to adapt either the patient position or the treatment plan, to account for variable organ locations. In this article, we briefly review the different adaptive methods being explored and discuss a proposed dose-guided radiation therapy strategy that adapts the treatment for future fractions to compensate for dosimetric errors from past fractions. The main component of this strategy is a procedure to reconstruct the dose delivered to the patient based on treatment-time portal images and pre-treatment megavoltage cone-beam computed tomography (MV CBCT) images of the patient. We describe the work to date performed to develop our dose reconstruction procedure, including the implementation of a MV CBCT system for clinical use, experiments performed to calibrate MV CBCT for electron density and to use the calibrated MV CBCT for dose calculations, and the dosimetric calibration of the portal imager. We also present an example of a reconstructed patient dose using a preliminary reconstruction program and discuss the technical challenges that remain to full implementation of dose reconstruction and dose-guided therapy.

Calibration↗

Evaluation of ultrasound-based prostate localization for image-guided radiotherapy.

To evaluate the use of the ultrasound-based BAT system for daily prostate alignment. Prostate alignments using the BAT system were compared with alignments using radiographic images of implanted radiopaque markers. The latter alignments were used as a reference. The difference between the BAT and marker alignments represents the displacements that would remain if the alignments were done using ultrasonography. The inter-user variability of the contour alignment process was assessed. On the basis of the marker alignments, the initial displacement of the prostate in the AP, superoinferior, and lateral direction was -0.9 +/- 3.9, 0.1 +/- 3.9, and 0.2 +/- 3.4 mm respectively. The directed differences between the BAT and marker alignments in the respective directions were 0.2 +/- 3.7, 2.7 +/- 3.9, and 1.6 +/- 3.1 mm. The occurrence of displacements >/=5 mm was reduced by a factor of two in the AP direction after the BAT system was used. Among eight users, the average range of couch shifts due to contour alignment variability was 7, 7, and 5 mm in the antero-posterior (AP), superoinferior, and lateral direction, respectively. In our study, the BAT alignments were systematically different from the marker alignments in the superoinferior, and lateral directions. The remaining random variability of the prostate position after the ultrasound-based alignment was similar to the initial variability. However, the occurrence of displacements >/=5 mm was reduced in the AP direction. The inter-user variation of the contour alignment process was significant.

Humans↗

Robustness and precision of an automatic marker detection algorithm for online prostate daily targeting using a standard V-EPID.

An algorithm for the daily localization of the prostate using implanted markers and a standard video-based electronic portal imaging device (V-EPID) has been tested. Prior to planning, three gold markers were implanted in the prostate of seven patients. The clinical images were acquired with a BeamViewPlus 2.1 V-EPID for each field during the normal course radiotherapy treatment and are used off-line to determine the ability of the automatic marker detection algorithm to adequately and consistently detect the markers. Clinical images were obtained with various dose levels from ranging 2.5 to 75 MU. The algorithm is based on marker attenuation characterization in the portal image and spatial distribution. A total of 1182 clinical images were taken. The results show an average efficiency of 93% for the markers detected individually and 85% for the group of markers. This algorithm accomplishes the detection and validation in 0.20-0.40 s. When the center of mass of the group of implanted markers is used, then all displacements can be corrected to within 1.0 mm in 84% of the cases and within 1.5 mm in 97% of cases. The standard video-based EPID tested provides excellent marker detection capability even with low dose levels. The V-EPID can be used successfully with radiopaque markers and the automatic detection algorithm to track and correct the daily setup deviations due to organ motions.

Algorithms↗

Inverse planning anatomy-based dose optimization for HDR-brachytherapy of the prostate using fast simulated annealing algorithm and dedicated objective function.

An anatomy-based dose optimization algorithm is developed to automatically and rapidly produce a highly conformal dose coverage of the target volume while minimizing urethra, bladder, and rectal doses in the delivery of an high dose-rate (HDR) brachytherapy boost for the treatment of prostate cancer. The dwell times are optimized using an inverse planning simulated annealing algorithm (IPSA) governed entirely from the anatomy extracted from a CT and by a dedicated objective function (cost function) reflecting clinical prescription and constraints. With this inverse planning approach, the focus is on the physician's prescription and constraint instead of on the technical limitations. Consequently, the physician's control on the treatment is improved. The capacity of this algorithm to represent the physician's prescription is presented for a clinical prostate case. The computation time (CPU) for IPSA optimization is less than 1 min (41 s for 142915 iterations) for a typical clinical case, allowing fast and practical dose optimization. The achievement of highly conformal dose coverage to the target volume opens the possibility to deliver a higher dose to the prostate without inducing overdosage of urethra and normal tissues surrounding the prostate. Moreover, using the same concept, it will be possible to deliver a boost dose to a delimited tumor volume within the prostate. Finally, this method can be easily extended to other anatomical sites.

Algorithms↗

Automated seed detection and three-dimensional reconstruction. I. Seed localization from fluoroscopic images or radiographs.

An automated procedure for the detection of the position and the orientation of radioactive seeds on fluoroscopic images or scanned radiographs is presented. The extracted positions of seed centers and the orientations are used for three-dimensional reconstruction of permanent prostate implants. The extraction procedure requires several steps: correction of image intensifier distortions, normalization, background removal, automatic threshold selection, thresholding, and finally, moment analysis and classification of the connected components. The algorithm was tested on 75 fluoroscopic images. The results show that, on average, 92% of the seeds are detected automatically. The orientation is found with an error smaller than 50 for 75% of the seeds. The orientation of overlapping seeds (10%) should be considered as an estimate at best. The image processing procedure can also be used for seed or catheter detection in CT images, with minor modifications.

Algorithms↗

Automated seed detection and three-dimensional reconstruction. II. Reconstruction of permanent prostate implants using simulated annealing.

We present an algorithm, based on simulated annealing, for automatic seed matching and three-dimensional spatial coordinate reconstruction using either three radiographic films or three fluoroscopic images taken from different perspectives. The matching problem is defined in the framework of combinatorial optimization, which allows robust reconstruction in presence of calibration imprecision, patient movements, and isometric distortions. Furthermore, by using a global criterion to select the correct matching, we evade common problems of the three-film method and its variants in presence of noise. The algorithm has been tested on 112 clinical cases and 100 simulated implants and used clinically on more than 100 cases. Simulated implants were reconstructed with an average error of 0.21 mm. For clinical cases, comparison of the precision is performed between results obtained with this new method and results obtained using the three-film technique. Compared to the latter technique, the reconstruction precision was improved in 62% of the clinical cases.

Algorithms↗

Seed misplacement and stabilizing needles in transperineal permanent prostate implants.

BACKGROUND AND PURPOSE: Seed misplacement occurring in transperineal permanent implants contributes to the degradation in dose coverage. It has been suggested that needles could be used to immobilize the prostate and help reduce misplacement. This study investigates the effects of parallel stabilizing needles on seed misplacement. MATERIALS AND METHODS: A group of ten patients implanted with stabilizing needles was compared with a group of 20 patients implanted without stabilization. Measurements were performed on the displacement of individual seeds and needles. The needle measurements are: insertion angle, the ratio of post-implant over pre-implant lengths and the clustering tendency, a measure of relative misplacement among the seeds of the same needle. RESULTS: No difference was observed in seed misplacement. No difference was observed in needle insertion angle, a measure which was expected to improve with the use of stabilizing needles. CONCLUSION: None of the expected effects from the use of parallel stabilizing needles have been observed. This method of prostate contention appears to be without benefits. Seed misplacement is most pronounced along the insertion axis and is caused by friction between prostatic tissues and implantation needles. Reducing friction could be a promising alternative to prostate contention in trying to reduce misplacement.

Algorithms↗

Observation study of electronic portal images for off-line verification.

PURPOSE: The goals of this study were to evaluate the use of electronic portal imaging device (EPID) paper images as off-line verification tools and to assess the feasibility of replacing portal films by EPID printed images. MATERIALS AND METHODS: Electronic portal images were acquired using a video-based imaging system. After contrast enhancement, these images were printed and compared to portal films when prescribed, and judged about their usefulness for off-line verification. A total of 2025 images were acquired from 322 fields on 137 patients. The images were shown to eight radiation oncologists and two senior residents in radiation oncology, each one of them judging fields relevant to his (her) daily practice. The questions asked were related to the choice of important anatomical structures and the visibility of such structures, the usefulness of the printed images, the comparison with portal films and the possible replacement of such films by paper images. RESULTS: Answers to the different questions were treated as quantitative scores. For the visibility question, means and standard deviations were calculated for each individual structure, then a global score was obtained for a given treatment site. Means and standard deviations were also computed for the comparison question. Proportions and confidence intervals were used for the other questions. The results show that EPID paper images are useful for some treatment sites such as breast, thorax, prostate, abdomen, pelvis (other than rectum) and axilla. The image quality remains insufficient for some other sites such as head and neck and spine. CONCLUSION: Although global anatomical landmarks scores are good, the usefulness score is not always as high because some essential anatomical structures scores must be taken into account. There is also a strong habit factor related to acceptance of EPID printed images as verification tools. As long as they see more and more images, radiation oncologists can more easily visualize anatomical structures and are less stringent when evaluating the efficiency of EPID paper images as off-line verification tools.

Electronics, Medical↗

A variable speed translating couch technique for total body irradiation.

We have developed a variable speed translating patient couch system for the delivery of total body irradiation (TBI). For a whole body Rando-type phantom, dose variation at mid-plane relative to the prescription point (navel) can be as high as 15% (neck or legs) with a constant velocity. By taking into account variations in body thickness, the intensity modulation radiation therapy, resulting from variable velocities, effectively delivers a uniform dose distribution at mid plane. The couch control user interface, technical aspects and dose planning optimization procedure for determining velocity distribution are described.

Biophysical Phenomena↗

Monte Carlo simulations of prostate implants to improve dosimetry and compare planning methods.

The objective of this study is to use Monte Carlo simulations to assess the sensitivity of implant planning methods to seed misplacement. A model of seed misplacement is first developed. It is based upon data gathered after a study on source migration performed on 30 patients treated with I-125 transperineal implants. It consists of applying elementary transformations to every needle in a loading plan to produce a distorted implant mimicking the effect of migration. After being validated, the model has been used to tune the inverse planning system in use at our institution. The new planning system is now used clinically and actual results are compared with those predicted by simulations. Simulations were also used to compare our planning method with others. The new planning system increased the average postimplant dose-volume histogram DVH(160) from 82% to 93%, which is the value predicted by the simulations. This improvement is due to an increased dose margin providing coverage even in the presence of migration. At the same time, the dose to the urethra remained at 267 Gy because of a special protection feature included in the planning system. Some other implant planning methods are not as robust [average DVH(160) ranging from 76% to 85%] and deliver a higher dose to the urethra (close to 400 Gy). To conclude, a simple model of source migration can provide realistic feedback about sensitivity to migration of planning methods. It allowed a significant clinical improvement at our institution. The improved inverse planning system provided better coverage with fewer seeds (but equal total activity) than a manual method. Hence, a properly tuned inverse planning system has the potential to deliver the less sensitive plans. The model also helped demonstrate that planning methods are not equally robust to migration and that they should not be evaluated solely by the plans they produce, but also by their clinical (or simulated) results.

Biophysical Phenomena↗

Miniature scintillating detector for small field radiation therapy.

In planning stereotactic radiosurgery treatments, depth dose curves, profiles, and dose rate of treatment beams are difficult to obtain with conventional detectors because of loss of lateral electronic equilibrium and volume averaging. A scintillating detector with high spatial resolution and good reliability has been developed to overcome this problem. The miniature dosimeter consists of two identical radiation-resistant 10 m long silica optical fibers, each connected to an independent silicon photodiode. A small cylindrical polystyrene scintillator (3.9 mm3) is optically glued to the detection fiber. The light seen by the photodiode connected to this fiber arises from fluorescence of the scintillator and from the Cerenkov effect produced in silica. The reference signal produced by the fiber without scintillator is used to subtract the Cerenkov light contribution from the raw detector response. The sensitive volume of the scintillating detector is nearly water-equivalent and thus minimizes dose distribution perturbation in water. The miniature dosimeter has a spatial resolution comparable to the film-densitometer system. Profiles of 1 cm diam, 6 MV photon beam measured with both systems show very similar shapes. Furthermore, the use of photodiodes instead of photomultiplier tubes gives a better stability response and offers the possibility to perform absolute dosimetry.

Gamma Cameras↗

Automatic setup deviation measurements with electronic portal images for pelvic fields.

The purpose of this work was to develop a fully automatic tool for the detection of setup deviation for small pelvic field using, in external beam radiotherapy, an electronic portal imaging device (EPID). The algorithm processes electronic portal images of prostate cancer patients. No fiducial points or user interventions are needed. Deviation measurements are based on bone edge detection performed with Laplacian of a Gaussian (LoG) operator. Two bone edge images are then correlated, one of which is a reference image taken as the first fraction image for the purpose of this study. The electronic portal images (EPI) also show band artefacts which are removed using the morphological top-hat transform. The algorithm was first validated with 59 phantom images acquired in clinical treatment conditions with known displacements. The algorithm was then validated with 79 clinical images where bone contours were delineated manually. For the phantom images, the setup deviations were measured with a absolute mean error of 0.59 mm and 0.47 mm with a standard deviation of 0.64 mm and 0.42 mm, horizontally and vertically, respectively. A second validation was performed using clinical prostate cancer images. The measured patient displacements have an absolute mean error of 0.48 mm and 1.41 mm with a standard deviation of 0.58 mm and 1.30 mm in the X and Y directions, respectively. The algorithm execution time on a SUN workstation is 5 s. This algorithm shows good potential as a setup deviation measurement tool in clinical practice. The possibility of using this algorithm combined with decision rules based on statistical observations is very promising.

Algorithms↗

Electronic portal imaging device detection of radioopaque markers for the evaluation of prostate position during megavoltage irradiation: a clinical study.

PURPOSE: This study was designed to assess daily prostatic apex motion relative to pelvic bone structures during megavoltage irradiation. METHODS AND MATERIALS: Radioopaque markers were implanted under ultrasound guidance near the prostatic apex of 11 patients with localized prostatic carcinoma. Patients were subsequently treated with a four field-box technique at a beam energy of 23 MV. During treatment, on-line images were obtained with an electronic portal imaging device (EPID). The marker was easily identified, even on unprocessed images, and the distance between the marker and a bony landmark was measured. Timelapse movies were also reviewed. After the completion of treatment, a transrectal ultrasound examination was performed in 8 of 11 patients, to verify the position of the marker. RESULTS: We acquired over 900 digital portal images and analyzed posterioanterior and right lateral views. The quality of portal images obtained with megavoltage irradiation was good. It was possible to evaluate pelvic bone structures even without image histogram equalization. Moreover, the radioopaque marker was easily visible on every online portal image. The review of timelapse movies showed important interfraction motion of the marker while bone structures remained stable. We measured the position of the marker for each fraction. Marker displacements up to 1.6 cm were measured between 2 consecutive days of treatment. Important marker motions were predominantly in the posteroanterior and cephalocaudal directions. In eight patients, we verified the position of the marker relative to the prostatic apex with ultrasound at the end of the treatments. The marker remained in the trapezoid zone. Intratreatment images reviewed in two cases showed no-change in marker position. Our results, obtained during the treatment courses, indicate similar or larger prostate motions than previously observed in studies that used intertreatment x-ray films and CT images. Marker implantation under transrectal ultrasound was well tolerated. CONCLUSIONS: Radioopaque marker and the use of electronic portal imaging give a direct evaluation of prostatic motion during radiation treatment. As suggested in previous studies the motions observed are predominantly in the posteroanterior and cephalocaudal directions. Therefore, prostate motion during treatment is important and must be considered especially when using conformal therapy.

Carcinoma↗

A new penumbra generator for electron fields matching.

Abutment of two or more electron fields to irradiate extended areas may lead to significant dose inhomogeneities in the junction region. This paper describes the geometric and dosimetric characteristics of a device developed to modify the penumbra of an electron beam and thereby improve the dose uniformity in the overlap region when fields are abutted. The device is a Lipowitz metal block placed on top of the electron applicator's insertion plate and positioned to stop part of the electron beam on the side of field abutment. The air-scattered electrons beyond the block increase the penumbra width from about 1.4 to 2.7-3.4 cm with an SSD of 100 cm. The modified penumbra is broad and almost linear at all depths for the 9 and 12 MeV electron beams used in this study. Film dosimetry was used to obtain beam profiles and isodose distributions of single modified beams and matched fields of 9 and 12 MeV as well as matched fields of both energies. Computer simulation was used to optimize the skin gap to be used and to quantify the dose uniformity as a function of the field separation for both modified and nonmodified beams. Results are presented for various field configurations. Without the penumbra generator, lateral setup errors of 2-3 mm may introduce dose variations of 20% or more in the junction region. Similar setup errors cause less than 5% dose variations when the penumbra generator is used to match the fields. The potential of the technique for the irradiation of curved surfaces is presented. A possible method for implementing the modified penumbra into a conventional treatment planning system is evaluated.

Electrons↗

Optimization of permanent 125I prostate implants using fast simulated annealing.

PURPOSE: Treatment planning of ultrasound-guided transperineal 125I permanent prostatic implants is a time-consuming task, due to the large number of seeds used and the very large number of possible source arrangements within the target volume. The goal of this work is to develop an algorithm based on fast simulated annealing allowing consistent and automatic dose distribution optimization in permanent 125I prostatic implants. METHODS AND MATERIALS: Fast simulated annealing is used to optimize the dose distribution by finding the best seed distribution through the minimization of a cost function. The cost function includes constraints on the dose at the periphery of the planned target volume and on the dose uniformity within this volume. Adjustment between peripheral dose and the dose uniformity can be achieved by varying the weight factor in the cost function. RESULTS: Fast simulated annealing algorithm finds very good seed distributions within 20,000 iterations. The computer time needed for the optimization of a typical permanent implant involving 60 seeds and 14 needles is approximately 15 min. An additional 5 min are necessary for isodose distribution computations and miscellaneous outputs. CONCLUSION: The use of fast simulated annealing allows for an efficient and rapid optimization of dose distribution. This algorithm is now routinely used at our institution in the clinical planning of 125I permanent transperineal prostate implants for early stage prostatic carcinoma.

Algorithms↗