Effects of body mechanics training on performance of repetitive lifting.

OBJECTIVE: To measure the efficacy of body mechanics instruction (BMI) in patients with low back pain. METHOD: The effect of BMI was measured in four participants with back injuries using a standardized lifting protocol. Static strength, weight lifted, number of lifts completed, and motion analysis data to describe the body mechanics were measured before and after work hardening to evaluate treatment effects. The participants' performances were compared with 52 controls from an earlier study. RESULTS: Starting postures, characterized by degrees of hip and knee flexion, varied by participant but favored a squat lift in three participants when compared with the controls. Dynamic motion synchrony of the hip and knee joints was similar to controls in three of the four participants. Posttest data revealed significant changes in static strength, dynamic endurance, and lifting speed. CONCLUSION: Intensive instruction in body mechanics provided during the work-hardening treatment produced major changes in lifting styles, in terms of both starting postures and dynamic aspects of repetitive lifting. The computerized measurement procedures used in this study permitted more careful and detailed analyses of body mechanics, particularly dynamic aspects, than is possible with observational methods. This study demonstrated some of the inherent intricacies in isodynamic lifting and suggests additional areas of performance that may be important to address in BMI.

Adult↗

Controller for an axial-flow blood pump.

An axial-flow ventricular assist device (VAD) under development at the authors' facility is intended for use as a long-term implantable device. At high speeds axial-flow VADs can collapse the native ventricle and damage the heart muscle, lung tissue, and blood. A prototype algorithm was developed to maintain physiologic perfusion to the vital organs while preventing ventricular collapse, through analysis of the electrical current waveform of the motor. The premise of the control algorithm is that the hemodynamics of the patient are reflected in the shape of this waveform. This approach is intended to eliminate the need for invasive sensors, thus effectively using the pump itself as a transducer. The control algorithm regulates the speed of the pump by comparing the motor-current waveform with reference waveforms using a matched filter. The matched filter was evaluated by its classification and differentiation performance. Thus far, the authors have been able to classify the waveforms into one of the four physiologic regions (below, within, or above the optimal range, and ventricular suction) with over 90% reliability. Ongoing work is directed toward improving the detection of ventricular suction, as this condition must be strictly avoided.

Algorithms↗