PubMed HealthSearch

Biomedical subjects

J R Bove

Publications and source records attributed to J R Bove.

13 recordsLinked to original sources

Blood donation and transfusion practices: the 1990 American Association of Blood Banks Institutional Membership Questionnaire.

Responses to the 1990 American Association of Blood Banks (AABB) Institutional Membership Questionnaire were submitted by 2126 regional blood centers, hospital-based blood banks, and transfusion facilities. Data from 2117 of these facilities were considered to be valid. The questionnaire included information on blood donor demographics, number of units collected, and collection procedures; services performed; usage of blood components; and transfusion-transmitted diseases reported during 1989. Institutional members collected 7.4 million whole blood units, of which 90.8 percent were donated for allogeneic use, 6.0 percent were donated for autologous use, and 3.2 percent were donated for directed use. Approximately 630,546 allogeneic and directed-use blood donors were deferred, most often for low hemoglobin or hematocrit values. Approximately 225,205 full allogeneic and directed-donor units were discarded, primarily for elevated alanine aminotransferase levels or the presence of hepatitis B core antibody. The 14.3 million transfused components included 56.7 percent red cell-containing components, 27.4 percent platelets, 11 percent fresh-frozen plasma, and 4.8 percent cryoprecipitate. Institutional members reported 1397 cases of transfusion-associated hepatitis. In this group, 921 patients were tested for hepatitis B surface antigen after the transfusion; 339 (36.8%) were found to be hepatitis B surface antigen positive. The AABB Institutional Questionnaire results provide recent data on blood donor and transfusion-related activities that are vital to the evaluation of current transfusion medicine practices.

Acquired Immunodeficiency Syndrome

Testing in the years ahead: new pressures and new concerns.

In the past, testing by blood banks was intended primarily to ensure product quality or donor safety or to meet existing regulations. As a result of recent pressures, especially the AIDS epidemic, additional reasons to test have become evident. Although some of these reasons are not easy to accept, it is appropriate to review them and to evaluate a new approach to reaching blood bank decisions that have public policy implications. It is suggested that The Institute of Medicine of the National Academy of Sciences sponsor a new and permanent structure for this purpose.

Acquired Immunodeficiency Syndrome

Long-term granulocyte transfusion in patients with malignant neoplasms.

Thirty-eight episodes of culture-documented antibiotic-resistant bacterial or fungal infection in patients with malignant neoplasms were treated with daily granulocyte transfusions until the infection improved or the patient died. Cumulative summation temperature plotting allowed easier interpretation of recipient fever response. Seventy-one percent of recipients had a favorable response to transfusion. There was no difference in mortality between patients treated with cells collected by filtration (FL) or intermittent flow centrifugation (IFCL) leukapheresis techniques. Transfusion reactions were more than twice as common with FL than IFCL collected cells. Seventy-four percent of recipients were alive 21 days after completion of transfusions; of the ten deaths, five could be classified as granulocyte transfusion failures. This study suggests that long-term granulocyte transfusion may be required in infected recipients when autologous granulocytes do not return after chemotherapy.

Abscess

Un-cross-matched blood for emergency transfusion. One year's experience in a civilian setting.

One year's experience (56 cases) in the use of un-cross-matched blood for emergency transfusion in a large civilian teaching hospital showed that 49 transfusions were given as un-cross-matched, group-specific (ABO and Rh) blood in emergencies. Seventy-seven percent (43) of blood requests were for patients with trauma, unexpected massive intraoperative hemorrhage, or ruptured aneurysm. The indications for emergency transfusion were questionable in ten cases. There were no adverse effects noted even though complete serologic testing had not been done. While the use of un-cross-matched blood is usually safe, the potential for serious reaction exists. Overuse should be discouraged.

ABO Blood-Group System

Chemical and hematological changes in stored CPD blood.

Blood was drawn from ten healthy volunteer donors into citrate-phosphate-dextrose (CPD) anticoagulant and placed on the quarantine shelf of the blood bank refrigerator. Plasma dextrose, sodium, potassium, chloride, bicarbonate, GOT, LDH, and hemoglobin as well as WBC, hematocrit, MCV, MCHC, whole blood pH, and ammonia were measured on all samples initially and at one, two, seven, 14, 21, and 28 days of storage at 4 C. Whole blood lactate also was analyzed serially on five of the units. An additional 27 units of CPD bank blood (two to 21 days of age), routinely processed, handled, and stored by the blood bank, were submitted to the same analyses on the day of administration to the patient. Five of these processed units, 21 days old, were resampled at 28 days. Results of the analyses are presented and discussed. The most pronounced changes were seen for dextrose, potassium, bicarbonate, lactate, LDH, ammonia, and hemoglobin. Plasma dextrose and bicarbonate declined in concentration while potassium, lactate, LDH, ammonia, and hemoglobin rose with storage. In general, changes in the regularly processed, singly sampled bank units were greater than those observed in the specially processed, quarantined units sampled serially. This study indicates that routine transportation, processing, and handling of bank blood may lead to increased biochemical alteration.

Ammonia

Unusual response to ABO incompatible blood transfusion.

Three units of group A blood were inadvertently administered to a group O recipient during surgery without evidence of hemoglobinemia, hemoglobinuria, hypotension, disseminated intravascular coagulation, acute renal tubular necrosis, or other signs and symptoms of transfusion reaction. The recipient had normal concentrations of IgG, IgA, and IgM as well as complement (C3) prior to transfusion and anti-A agglutinins titered to 64 (titer of 128 by the antiglobulin technic). Seventeen hours following the transfusion, 28 per cent of the circulating red blood cells were group A (equivalent to 475 ml of packed cells); they were eliminated by day 5 without evidence of hemoglobinuria, hemoglobinemia or hyperbilirubinemia. Anti-A titers (antiglobulin) had risen from a posttransfusion low of 4 to 4,096 by day 10. After treatment of serum with 2-mercaptoethanol, however, hemolytic activity which was first noted on day 5 was lost and the antiglobulin titer dropped to 24 which suggested that most of the anti-A produced in response to the transfusion was IgM rather than IgG. The anti-A titer had dropped to essentialyy pretransfusion levels and the majority of anti-A present was IgM by day 91. The recipient suffered no untoward effects from the transfusion and was in good health three months following the transfusion.

ABO Blood-Group System

Plasmapheresis using the IBM 2991 blood cell processor.

The IBM 2991 Blood Cell Processor, normally used to wash or deglycerolize red blood cells, has been modified to permit serial plasmapheresis using a small roller pump, an adapter line and the disposable processing set usually used for cell washing. Blood is withdrawn from the donor, pumped into the plastic centrifuge bag and the plasma removed after centrifugation. Donor erythrocytes are pumped from the processing bag to a reservoir bag from which they are returned to the donor by gravity. Multi-unit plasmapheresis to harvest plasma for transfusion or to remove plasma as a therapeutic measure is possible using the modified system. A four-unit plasmapheresis can be done in 65 to 75 minutes at a cost of $27.61, including disposables and technologist labor. This modification allows the IBM 2991 to function for red blood cell washing and as an efficient instrument for plasmapheresis.

Blood Donors

Transfusion-transmitted diseases other than AIDS and hepatitis.

Although the major diseases transmitted by transfusion today are AIDS and hepatitis, many others also are known. These include CMV, syphilis, Chagas disease, babesiosis, parvovirus B19, malaria, Epstein-Barr infection, and many others that have been reported only once or twice. Reducing the risk of transfusion-transmitted diseases is a problem for donor centers where donor screening and laboratory testing for possible carriers is undertaken. Physicians should be aware that the potential for disease transmission is always present when transfusions are administered.

Animals