Antimicrobial efficacy of endoscopic disinfection procedures: a controlled, multifactorial investigation.

BACKGROUND: Adequate disinfection of endoscopes is essential to prevent environmental and patient-to-patient transmission of infectious agents, but data from controlled studies are limited. Moreover, there is controversy regarding current guidelines for disinfection. We compared the antimicrobial efficacy of several endoscopic disinfection procedures controlling for multiple factors that affect reprocessing. METHODS: A colonoscope was contaminated with 10(8) CFU/mL of Enterococcus faecalis as a standardized inoculum. The colonoscope was passed through 1 of 16 study arms (5 reps/arm for a total of 80 runs) that were controlled for all possible combinations of the following variables: manual precleaning; 10-, 20-, or 45-minute glutaraldehyde exposure; air or ethanol drying; or automated reprocessing with peracetic acid (liquid sterilization system). Suction accessory channels and air-water channels were harvested for microbiologic culture. RESULTS: Control runs (no cleaning or disinfection) recovered more than 5 x 10(7) CFU/mL from each sampling site. When each processing variable was isolated independent of other variables, the benefits of manual precleaning, longer soak times, and ethanol drying were apparent. When factors were combined, manual precleaning followed by 20- and 45-minute glutaraldehyde exposure and ethanol drying removed all test organisms, as did processing with the liquid sterilization system. CONCLUSION: Although the initial cost is higher, the automated liquid sterilization system provides effective sterilization and minimizes worker exposure. In units where chemical disinfection is used, our results suggest that manual precleaning followed by at least 20-minute glutaraldehyde exposure and ethanol rinse drying are sufficient to achieve complete disinfection.

Colony Count, Microbial↗

Efficacy of conventional endoscopic disinfection and sterilization methods against Helicobacter pylori contamination.

BACKGROUND: Iatrogenic transmission of Helicobacter pylori via contaminated endoscopic devices is well documented. Despite the prevalence of this infectious agent, few controlled studies have investigated the major factors that impact on reprocessing of endoscopes contaminated with H. pylori. MATERIALS AND METHODS: An endoscope (Pentax) was contaminated with 108 cfu/ml of H. pylori in 5% bovine calf serum as standardized inoculum. The endoscope then was passed through one of eight arms (five repetitions per arm = 40 total runs), as follows: 1, recovery control (no cleaning or disinfection); 2, manual cleaning alone; 3-5, manual precleaning followed by either 10-, 20-, or 45-minute exposure to 2% glutaraldehyde and ethanol (ETOH) drying; 6, manual cleaning followed by automated reprocessing by STERIS System; 7 and 8, automated reprocessing by STERIS with and without active peracetic acid sterilant (wash-off control). Suction-biopsy channels and air-water channels were harvested for microbiological culture. RESULTS: Control runs recovered more than 1 x 106 cfu per site, confirming the viability of the test organism and the adequacy of the biological burden for challenge. When instruments underwent manual cleaning alone (without subsequent disinfection), test organisms remained in 40% of runs at the air-water site. Manual cleaning followed by 10-, 20-, or 45-minute glutaraldehyde exposure and ETOH drying removed all test organisms from all sites in all runs (i.e., 100% disinfection). The automated STERIS system with or without active peracetic acid sterilant also removed all test organisms from all sites in all runs, as did manual cleaning followed by STERIS use. CONCLUSION: Manual cleaning alone does not effectively remove H. pylori from an endoscope. Current joint association recommendations for minimal disinfection (manual cleaning followed by at least 20 minutes of immersion in glutaraldehyde and ETOH drying) are effective in preventing cross-transmission of H. pylori. Reprocessing using the automated STERIS system according to manufacturer's recommendations also is highly effective in sterilizing endoscopes contaminated with H. pylori.

Cross Infection↗