PubMed Health⌕ Search

Biomedical subjects

J R Gauger

Publications and source records attributed to J R Gauger.

18 recordsLinked to original sources

Evaluation of the developmental toxicity of 60 Hz magnetic fields and harmonic frequencies in Sprague-Dawley rats.

Experimental data suggest that exposure to the 50 and 60 Hz sinusoidal components of power-frequency magnetic fields (MFs) does not have an adverse impact on fetal development. However, the possible developmental toxicity of MF harmonics has not been investigated. This study was designed to determine whether exposure to 180 Hz MFs (third harmonic), alone or in combination with 60 Hz MFs, induces birth defects in Sprague-Dawley rats. Groups of sperm-positive dams (> or =20/group) were exposed for 18.5 h per day from gestation days 6 through 19 to (1) ambient MFs only (<0.0001 mT; sham controls); (2) 60 Hz MFs at 0.2 mT; (3) 180 Hz MFs at 0.2 mT; or (4) 60 Hz + 180 Hz MFs (10% third harmonic; total field strength = 0.2 mT). Litter size, litter weight, percentage live births, sex ratio, and number of resorption sites were determined for each dam, and gross external, visceral, cephalic and skeletal examinations were performed on all fetuses. MF exposure had no significant effects on litter size, litter weight, or fetal development. With the exception of common rib variants, the incidence of fetal anomalies was comparable in all groups. A small increase in the incidence of rib variants was seen in the group exposed to 60 Hz + 180 Hz MFs; however, the incidence of rib variants in this group was similar to that in historical controls from our laboratory. These data extend the existing database on developmental toxicity of MFs by demonstrating that exposure to 180 Hz MFs, either alone or superimposed on an underlying 60 Hz signal, does not induce biologically significant developmental toxicity. These data do not support the hypothesis that exposure to power-frequency MFs is an important risk factor for fetal development.

Animals↗

Expression of cancer-related genes in human cells exposed to 60 Hz magnetic fields.

Exposure to 60 Hz magnetic fields (MFs) may be a risk factor for human cancer. One mechanism through which MFs could influence neoplastic development is through alterations in the expression of cancer-related genes. Previous molecular studies of the action of MFs have measured effects on a limited number of genes. In the present studies, arrays containing cDNAs for 588 cancer-related genes were used to approach the hypothesis that the biological activity of MFs is mediated by alterations in gene expression. Cultures of normal (HME) and transformed (HBL-100) human mammary epithelial cells and human promyelocytic leukemia (HL60) cells were exposed to MFs at field strengths of 0, 0.01 or 1.0 mT for 24 h. Several genes were identified in MF-exposed cells whose expression was increased by at least twofold or decreased by 50% or more. However, no gene was found to be differentially expressed in each of three independent exposures for any cell type, and no relationship between exposure intensity and differential gene expression was found. These studies failed to identify a plausible genetic target for the action of MFs in human cells, and they provide no support for the hypothesis that MF exposure alters the expression of genes that are involved in cancer development.

Breast↗

60 Hz magnetic fields do not enhance cell killing by genotoxic chemicals in Ataxia telangiectasia and normal lymphoblastoid cells.

Ataxia telangiectasia (AT) is an inherited autosomal recessive disease characterized by increased risk of cancer, immune deficiency, and neurodegeneration. Cells cultured from AT patients are highly sensitive to genotoxic agents and are deficient in cell cycle arrest after exposure to ionizing radiation. In consideration of their sensitivity to both ionizing and nonionizing radiation, AT cells may provide a sensitive model system to study the biological activity of other components of the electromagnetic spectrum. To characterize the effects of power-frequency (60 Hz) magnetic fields (MFs) in AT cells, we compared responses of AT and normal lymphoblast cells to sinusoidal MFs at 1.0 mT, either alone or in combination with the genotoxic agents mitomycin C or streptonigrin. The MF alone had no effect on cell growth or survival in a clonogenic assay in either AT or normal cells. The MF also had no effect on induction of cell death by mitomycin C or streptonigrin in either cell type. AT cells do not demonstrate differential sensitivity to MF exposure. These results do not support the hypothesis that MFs interact with genotoxic agents to induce adverse biological effects in either normal or genetically susceptible human cells.

Antibiotics, Antineoplastic↗

Cell viability and growth in a battery of human breast cancer cell lines exposed to 60 Hz magnetic fields.

Epidemiological data suggest that exposure to power-frequency (50/60 Hz) magnetic fields (MFs) may be a risk factor for breast cancer in humans. To determine whether MFs affect human breast cancer cells, we measured viability, growth and cytotoxicity in a battery of breast cancer cell lines after in vitro MF and sham exposure. Cells of three estrogen receptor-positive human breast cancer cell lines (MCF-7, ZR-75-1 and T-47D) and one estrogen receptor-negative human breast cancer cell line (MDA-MB-231) and normal (nontransformed) human breast epithelial cells were exposed to MFs (1 mT) or sham fields (<0.0001 mT) for 72 h. Cell viability was determined using the sulforhodamine B (SRB) assay at 0 and 72 h after the MF exposure period. Cell growth was measured as the change in SRB dye uptake over 72 h after MF exposure. MF exposure had no effect on cell viability or growth in any cell type examined. Similarly, MF exposure had no effect on cytotoxicity induced by exposure to the retinoid N-(4-hydroxyphenyl)retinamide. These data do not support the hypothesis that MF exposure stimulates growth of breast cancer cells.

Apoptosis↗

Multigeneration reproductive toxicity assessment of 60-Hz magnetic fields using a continuous breeding protocol in rats.

Male and female reproductive functions have been proposed as possibly sensitive targets for the biological effects of 60-Hz (power frequency) magnetic fields (MF). However, experimental data relevant to this hypothesized association are very limited. In the present study, the "reproductive assessment by continuous breeding" design was used to identify possible effects of MF exposure on reproductive performance, fetal development, and early postnatal growth in rats. Groups of age-matched Sprague-Dawley rats (40 breeding pairs/group) were exposed continuously (18.5 hr per day) to linearly polarized, transient-free 60-Hz MF at field strengths of 0 Gauss (G; sham control), 0.02 G, 2.0 G, or 10.0 G. An additional group of 40 breeding pairs received intermittent (1 hr on/1 hr off) exposure to 10.0 G fields. F0 breeding pairs were exposed to MF or sham fields for 1 week prior to mating, during a 14-week period of cohabitation, and during a 3-week holding period after cohabitation. The duration of the cohabitation period was selected to be sufficient for the delivery of five litters in the sham control group. Pups from the final F1 litter from each breeding pair were exposed to MF or sham fields until sexual maturity, were cohabitated in MF or sham fields for 7 days with nonsiblings from the same exposure group, and were held in the MF or sham fields for 22 days to permit delivery of F2 pups for evaluation. No evidence of exposure-related toxicity was identified in any rat in the F0, F1, or F2 generations. Fetal viability and body weights in all litters of groups exposed to MF were comparable to those of sham controls. No significant differences between sham controls and MF-exposed groups were seen in any measure of reproductive performance (litters/breeding pair, percent fertile pairs, latency to parturition, litter size, or sex ratio) in either the F0 or F1 generation. Exposure of Sprague-Dawley rats to 60-Hz MF strengths of up to 10.0 G either during their peak reproductive period (F0) or during gestation and throughout their life span (F1) has no biologically significant effects on reproductive performance. These results do not support the hypothesis that exposure to pure, linearly polarized 60-Hz MF is a significant reproductive or developmental toxicant.

Animals↗

Design, construction, and validation of a large capacity rodent magnetic field exposure laboratory.

A magnetic field exposure laboratory has been constructed to support National Toxicology Program studies for the evaluation of the toxicity and carcinogenicity of pure, linearly polarized, 60 Hz magnetic fields in rodents. This dual corridor, controlled access facility can support the simultaneous exposure of 1200 rats and 1200 mice. The facility contains fully redundant electrical and environmental control systems and was constructed using non-metallic materials to maintain low levels of background (ambient), stray, and cross-talk magnetic fields. The exposure module design provides for large uniform exposure volumes with good control of stray and cross-talk fields, while allowing the use of roll-around cage racks for simplified animal husbandry. Stray fields and cross-talk have been further reduced by the inclusion of "steering coils" in each exposure module. Ambient 60 Hz fields (less cross-talk) in all exposure rooms are <0.1 microT (1 mG), and static magnetic fields have been mapped extensively. Magnetic field strength, waveform, temperature, relative humidity, light intensity, noise level, vibration, and air flow in all animal holding areas are tightly regulated, and are monitored continuously during all studies. Field uniformity in the animal exposure volumes is better than -/+l0%; a systematic program of cage, rack, and room rotation controls for possible positional effects within the exposure system. Magnetic fields are turned on and off over multiple cycles to prevent the induction of transients associated with abrupt field level changes. Total harmonic distortion is <3% at all field strengths. The facility has been used to study magnetic field bioeffects in rodent model systems in experiments ranging in duration from 8 weeks to 2 years.

Air Movements↗

Gene expression in human breast epithelial cells exposed to 60 Hz magnetic fields.

Epidemiology suggests a possible relationship between exposure to power frequency magnetic fields (EMF) and breast cancer. One mechanism through which EMF could stimulate breast cancer induction is via altered expression of oncogenes and/or tumor suppressor genes that regulate normal and neoplastic growth. To evaluate the hypothesis that EMF action in the breast is mediated by alterations in gene expression, transcript levels of c-myc and a battery of other cancer-associated genes were quantitated in human breast epithelial cells exposed to pure, linearly polarized 60 Hz EMF with low harmonic distortion. HBL-100 cells and normal (non-transformed) human mammary epithelial cells were exposed to EMF flux densities of 0.1, 1.0 and 10.0 Gauss (G) for periods ranging from 20 min to 24 h; concurrent sham controls were exposed to ambient fields (<0.001 G) only. Gene expression was quantitated using ribonuclease protection assays. EMF exposure had no statistically significant effect on basal levels of c-myc transcripts in either human breast cell model, and had no effect on alterations in c-myc expression induced by 12-O-tetradecanoylphorbol-13-acetate. Transcript levels of c-erbB-2, p53, p21, GADD45, bax, bcl-x, mcl-1, and c-fos were also unaffected by EMF exposure. These results suggest that EMF is unlikely to influence breast cancer induction through a mechanism involving altered expression of these genes.

Breast↗

Exposure to 60 Hz magnetic fields and risk of lymphoma in PIM transgenic and TSG-p53 (p53 knockout) mice.

The results of a number of epidemiology studies suggest that exposure to power frequency (50 and 60 Hz) magnetic fields may be a risk factor for hematopoietic neoplasia. To generate experimental data to test this hypothesis, the influence of magnetic field exposure on lymphoma induction was determined in two strains of mice that are genetically predisposed to the disease. PIM mice, which carry the pim-1 oncogene, are highly sensitive to lymphoma induction by N-ethyl-N-nitrosourea (ENU); ENU-treated PIM mice were studied as a 'high incidence' lymphoma model. TSG-p53 (p53 knockout) mice, in which the p53 tumor suppressor gene has been deleted from the germ line, develop lymphoma as an age-related change; hemizygous TSG-p53 mice were studied as a 'low incidence' lymphoma model. Beginning 1 day after a single i.p. injection of 25 mg ENU/kg body wt, groups of 30 PIM mice/sex were exposed for 18.5 h/day to pure, linearly polarized, transient-free 60 Hz magnetic fields at field strengths of 0 (sham control), 0.02, 2.0 or 10.0 Gauss (G). An additional group of 30 PIM mice/sex was exposed intermittently (1 h on, 1 h off) to 10.0 G fields. Groups of 30 TSG-p53 mice/sex were exposed continuously to magnetic field strengths of 0 (sham control) or 10.0 G; TSG-p53 mice received no ENU. Studies were terminated after 23 weeks of magnetic field exposure. Lymphoma incidence in male PIM mice exposed continuously to 10.0 G magnetic fields was significantly reduced from that seen in sex-matched sham controls; survival, lymphoma incidence and lymphoma latency in other groups of PIM mice did not differ from sham controls. Survival and lymphoma incidence in all groups of TSG-p53 mice was 7% or less, regardless of magnetic field exposure regimen. These data do not support the hypothesis that exposure to magnetic fields is a significant risk factor for lymphoid neoplasia in mice with a genetic predisposition to the disease.

Animals↗

Eight-week toxicity study of 60 Hz magnetic fields in F344 rats and B6C3F1 mice.

Toxicity studies were performed by exposing F344/N rats and B6C3F1 mice (10 animals per sex per species per group) to transient-free, linearly polarized 60 Hz magnetic fields for 8 weeks. Targeted magnetic fields strengths used were 0 gauss (G; sham control fields did not exceed 0.001 G), 0.02 G, 2 G, and 10 G. Exposure was whole-body and continuous for 18.5 hr per day, 7 days per week. An additional group of rats and mice was exposed intermittently (1 hr on/1 hr off) to 10 G fields for the same period of time. Endpoints evaluated included morbidity, mortality, gross pathology, histopathology, body/organ weights, clinical chemistry (rats only), and hematology (rats only). All mice and all male rats survived until the end of the study. One female rat (2-G exposure group) died during Week 7 of the study; the death was not attributed to magnetic field exposure. In both studies, the mean body weight gains of exposed animals were similar to those of the respective controls. There were no gross, histological, hematological, or biochemical lesions attributed to magnetic field exposure. Statistically significant increases in liver weight and liver to body weight ratio occurred in female rats of all exposure groups but only at the termination. These data suggest that, for the variables evaluated in these studies, an 8-week exposure to linear-polarized, transient-free 60 Hz magnetic fields at field intensities of up to 10 G is not associated with significant toxicity in F344/N rats and B6C3F1 mice. Furthermore, there was no toxicity observed in animals receiving intermittent (1 hr on/1 hr off) exposures to 10-G fields. A 2-year study in F344/N rats and B6C3F1 mice is nearing completion of the in-life phase without overt toxicity in any exposed group. It is premature, however, to make any prediction concerning the possible influence of exposure to 60 Hz magnetic fields on cancer rates.

Animals↗

Developmental toxicity study of 60 Hz (power frequency) magnetic fields in rats.

Considerable public concern has developed regarding possible adverse reproductive outcomes resulting from exposure to power frequency magnetic fields (MF). To identify possible effects of MF exposure on fetal development, timed-pregnant female Sprague-Dawley rats (55/ group) received continuous exposure to linearly polarized, transient-free 60 Hz MF at field strengths of 0 Gauss (G; sham control), 0.02 G, 2 G, or 10 G, or intermittent (1 hr on/1 hr off) exposure to 10 G fields. Dams received MF or sham exposures for 18.5 hr/day on gestation days 6 through 19. A positive control group of 15 dams received daily oral doses of 85 mg ethylenethiourea (ETU)/kg body weight on gestation days 11, 12, and 13; positive control dams received no MF exposure. Ambient and experimentally generated MF were monitored continuously throughout the study. Experimentally generated MF were within 2% of the target field strengths at all times, and ambient MF to which sham controls were exposed did not exceed 0.7 mG at any point in the study. No evidence of maternal toxicity was identified in any MF-exposed dam; mean maternal body weight and organ weights in groups exposed to MF did not differ from those in sham controls. Comparisons of fetal viability and body weight demonstrated no biologically significant differences between MF-exposed groups and sham controls. Similarly, a battery of gross external, visceral, skeletal, and cephalic examinations demonstrated no significant differences in the incidence of fetal malformations or anomalies in MF-exposed groups vs. sham controls. By contrast, 100% of the fetuses in the positive control group treated with ETU demonstrated malformations and reduced body weight. Exposure of pregnant Sprague-Dawley rats to 60 Hz at field strengths up to 10 G during gestation days 6-19 did not produce biologically significant effects in either dams or fetuses. These results do not support the hypothesis that exposure to pure, linearly polarized 60 Hz MF is a significant risk factor for the developing fetus.

Abnormalities, Drug-Induced↗

Immune function and host defense in rodents exposed to 60-Hz magnetic fields.

This study was conducted to evaluate the influence of subchronic exposure to pure, linearly polarized 60-Hz magnetic fields (MF) on the host immune response in mice. The experimental design was as follows: three groups were exposed continuously (18.5 hr/day) to MF at field strengths of 0.02, 2, or 10 gauss (G), one group was exposed intermittently (1 hr on/1 hr off) to MF at a field strength of 10 G, and one group served as a sham control. Experimental endpoints included spleen and thymus weights and cellularity, antibody-forming cell (AFC) response, delayed-type hypersensitivity (DTH) response, splenic lymphocyte subset analysis, susceptibility to infection with Listeria monocytogenes, and natural killer (NK) cell activity. No differences in body weight, lymphoid organ weight, or lymphoid organ cellularity were observed in any MF-exposed group in comparison to sham controls. Likewise, no statistically significant differences were found in comparisons of AFC responses. Isolated statistically significant differences from control were observed in MF-exposed mice in the DTH assay, although no clear dose-related pattern of altered activity was seen. Splenic lymphocyte subset parameters examined were within normal limits in all groups, and no differences between control and MF-exposed mice were found. Host resistance to bacterial infection was not altered at any MF exposure examined in this study. Finally, although apparently dose-related, statistically significant alterations were observed in an initial study of NK cell function, repeat studies failed to demonstrate a consistent pattern of alteration.

Animals↗

Laboratory investigations of the electrical characteristics of honey bees and their exposure to intense electric fields.

Bees exposed to 60-Hz electric (E) fields greater than 150 kV/m show field-induced vibrations of wings, antennae, and body hairs. They also show altered behavior if exposed while in contact with a conductive substrate. Measurements indicate that approximately 240 nA is coupled to a bee standing on a conductive substrate in a 100-kV/m E field. In lab experiments, bee disturbance and sting result from exposure to E field greater than 200 kV/m (bee current greater than 480 nA) and reduced voluntary movements at greater than 300 kV/m (greater than 720 nA bee current) only if the bee is on a conductive substrate. It is hypothesized that in the latter situation coupled bee current drains through the lower thorax and legs to the conductive substrate, and that the resulting enhanced current density in these regions is the cause of observed responses. The observation that bees exposed to intense E fields on an insulator show vibration of body parts but no behavioral response suggests that vibration contributes little to the disturbance of bees in intense E fields. Lab measurements of bee impedance from front-to-rear leg pairs were made on wet and dry conductors. Measurements validate the selection of 1 M omega as a middle value for bee impedance used in the design of devices used to generate step-potential-induced currents in bees.

Animals↗

Exposure scheme separates effects of electric shock and electric field for honey bees, Apis mellifera L.

Mechanisms to explain disturbance of honey bee colonies under a 765-kV, 60-Hz transmission line [electric (E) field = 7 kV/m] fall into two categories: direct bee perception of enhanced in-hive E fields, and perception of shock from induced currents. The same adverse biological effects previously observed in honey bee colonies exposed under a 765-kV transmission line can be reproduced by exposing worker bees to shock or E field within elongated hive entranceways (= tunnels). Exposure to intense E field caused disturbance only if bees were in contact with a conductive substrate. E-field and shock exposure can be separated and precisely defined within tunnels, eliminating dosimetric vagaries that occur when entire hives are exposed to E field.

Animals↗

Mechanism of biological effects observed in honey bees (Apis mellifera, L.) hived under extra-high-voltage transmission lines: implications derived from bee exposure to simulated intense electric fields and shocks.

This work explores mechanisms for disturbance of honey bee colonies under a 765 kV, 60-Hz transmission line [electric (E) field = 7 kV/m] observed in previous studies. Proposed mechanisms fell into two categories: direct bee perception of enhanced in-hive E fields and perception of shock from induced currents. The adverse biological effects could be reproduced in simulations where only the worker bees were exposed to shock or to E field in elongated hive entranceways (= tunnels). We now report the results of full-scale experiments using the tunnel exposure scheme, which assesses the contribution of shock and intense E field to colony disturbance. Exposure of worker bees (1,400 h) to 60-Hz E fields including 100 kV/m under moisture-free conditions within a nonconductive tunnel causes no deleterious affect on colony behavior. Exposure of bees in conductive (e.g., wet) tunnels produces bee disturbance, increased mortality, abnormal propolization, and possible impairment of colony growth. We propose that this substrate dependence of bee disturbance is the result of perception of shock from coupled body currents and enhanced current densities postulated to exist in the legs and thorax of bees on conductors. Similarly, disturbance occurs when bees are exposed to step-potential-induced currents. At 275-350 nA single bees are disturbed; at 600 nA bees begin abnormal propolization behavior; and stinging occurs at 900 nA. We conclude that biological effects seen in bee colonies under a transmission line are primarily the result of electric shock from induced hive currents. This evaluation is based on the limited effects of E-field exposure in tunnels, the observed disturbance thresholds caused by shocks in tunnels, and the ability of hives exposed under a transmission line to source currents 100-1,000 times the shock thresholds.

Animals↗

Telephone communication system for handicapped individuals.

Simple low-cost telephone systems for independent use by individuals with limited upper extremity function are described. The systems can be easily assembled from readily available telephone components. Communication is accomplished through a telephone amplifier and uses operator-assisted dialing. Use requires the manipulation of only two switches. One switch connects the amplifier to the phone line; the other dials the operator. "Dial (0)" telephone systems, costing less than $100, are readily affordable for many handicapped individuals.

Communication Devices for People with Disabilities↗

Biological effects of a 765-kV transmission line: exposures and thresholds in honeybee colonies.

Honeybee colonies exposed under a 765-kV, 60-Hz transmission line at 7 kV/m show the following sequence of effects: 1) increased motor activity with transient increase in hive temperature; 2) abnormal propolization; 3) impaired hive weight gain; 4) queen loss and abnormal production of queen cells; 5) decreased sealed brood; and 6) poor winter survival. When colonies were exposed at 5 different E fields (7, 5.5, 4.1, 1.8, and 0.65-0.85 kV/m) at incremental distances from the line, different thresholds for biologic effects were obtained. Hive net weights showed significant dose-related lags at the following exposures: 7 kV/m, one week; 5.5 kV/m, 2 weeks; and 4.1 kV/m, 11 weeks. The two lowest exposure groups had normal weight after 25 weeks. Abnormal propolization of hive entrances did not occur below 4.1 kV/m. Queen loss occurred in 6 of 7 colonies at 7 kV/m and 1 of 7 at 5.5 kV/m, but not below. Foraging rates were significantly lower only at 7 and 5.5 kV/m. Hive weight impairment and abnormal propolization occur at lower E-field intensity than other effects and limit the "biological effects corridor" of the transmission line to approximately 23 m beyond a ground line projection of each outer phase wire. Intrahive E fields of 15-100 kV/m were measured with a displacement current sensor. Step-potential-induced currents up to 0.5 microA were measured in an electrically equivalent bee model placed on the honeycomb in a hive exposed at 7 kV/m. At 1.8 kV/m body currents were a few nanoamperes, or two orders of magnitude lower, and these colonies showed no effects. E-field versus electric shock mechanisms are discussed.

Animals↗

Chronic toxicity/oncogenicity evaluation of 60 Hz (power frequency) magnetic fields in F344/N rats.

A 2-yr whole-body exposure study was conducted to evaluate the chronic toxicity and possible oncogenicity of 60 Hz (power frequency) magnetic fields in rats. Groups of 100 male and 100 female F344/N rats were exposed continuously to pure, linearly polarized, transient-free 60 Hz magnetic fields at flux densities of 0 Gauss (G) (sham control), 20 milligauss (mG), 2 G, and 10 G; an additional group of 100 male and 100 female F344/N rats received intermittent (1 hr on/1 hr off) exposure to 10 G fields. Mortality patterns, body weight gains throughout the study, and the total incidence and number of malignant and benign tumors in all groups exposed to magnetic fields were similar to those found in sex-matched sham controls. Statistically significant increases in the combined incidence of C-cell adenomas and carcinomas of the thyroid were seen in male rats chronically exposed to 20 mG and 2 G magnetic fields. These increases were not seen in male rats exposed continuously or intermittently to 10 G fields or in female rats at any magnetic field exposure level. No increases in the incidence of neoplasms, which have been identified in epidemiology studies as possible targets of magnetic field action (leukemia, breast cancer, and brain cancer), were found in any group exposed to magnetic fields. There was a decrease in leukemia in male rats exposed to 10 G intermittent fields. The occurrence of C-cell tumors at the 2 lower field intensities in male rats is interpreted as equivocal evidence of carcinogenicity; data from female rats provides no evidence of carcinogenicity in that sex. These data, when considered as a whole, are interpreted as indicating that chronic exposure to pure linearly polarized 60 Hz magnetic fields has little or no effect on cancer development in the F344/N rat.

Adenoma↗

Chronic toxicity/oncogenicity evaluation of 60 Hz (power frequency) magnetic fields in B6C3F1 mice.

A 2-yr whole-body exposure study was conducted to evaluate the chronic toxicity and possible oncogenicity of 60 Hz (power frequency) magnetic fields in mice. Groups of 100 male and 100 female B6C3F1 mice were exposed to pure, linearly polarized, transient-free 60 Hz magnetic fields at flux densities of 0 Gauss (G) (sham control), 20 milligauss (mG), 2 G, and 10 G; an additional group of 100 male and 100 female B6C3F1 mice received intermittent (1 hr on/1 hr off) exposure to 10 G fields. A small but statistically significant increase in mortality was observed in male mice exposed continuously to 10 G fields; mortality patterns in all other groups of mice exposed to magnetic fields were comparable to those found in sex-matched sham controls. Body weight gains and the total incidence and number of malignant and benign tumors were similar in all groups. Magnetic field exposure did not increase the incidence of neoplasia in any organ, including those sites (leukemia, breast cancer, and brain cancer) that have been identified in epidemiology studies as possible targets of magnetic field action. A statistically significant decrease in the incidence of malignant lymphoma was observed in female mice exposed continuously to 10 G fields, and statistically significant decreases in the incidence of lung tumors were seen in both sexes exposed continuously to 2 G fields. These data do not support the hypothesis that chronic exposure to pure, linearly polarized 60 Hz magnetic fields is a significant risk factor for neoplastic development in mice.

Adenoma↗