PubMed Health⌕ Search

Biomedical subjects

J R Hadley

Publications and source records attributed to J R Hadley.

3 recordsLinked to original sources

Radio-frequency coil selection for MR imaging of the brain and skull base.

Radio-frequency coils play a crucial role in the quest for optimal magnetic resonance (MR) image resolution. Given the growing variety of specialized coils available for neuroradiologic imaging applications, it is critical that radiologists use a coherent strategy for successfully matching these coils to specific imaging situations. First, fundamental concepts of coil design are reviewed. Subsequently, a coil-selection algorithm for neuroimaging applications is described. The algorithm uses the patient's clinical history to derive a region of interest, a desired spatial resolution, and a desired contrast resolution. These factors are then used to impose anatomic coverage and imaging protocol constraints on the set of available coils. Finally, coil selection is further refined according to patient tolerance factors. The following coils are considered for use with a 1.5-T superconducting MR imager; namely, quadrature birdcage head, neurovascular phased-array, and dual single-circular-element coils, as well as investigational coils that have not yet been approved by the U.S. Food and Drug Administration: reduced-volume birdcage end-cap, temporal lobe phased-array, carotid artery phased-array, coils. Rationales are discussed regarding appropriate coil selection for screening whole brain and imaging brainstem, cranial nerves, orbits, cerebral cortex, mesial temporal lobes, and internal auditory canal, and for MR angiography.

Algorithms↗

A three-coil comparison for MR angiography.

The purpose of this work was to compare intracranial magnetic resonance angiography (MRA) image quality using three different radiofrequency coils. The three coil types included a reduced volume quadrature birdcage coil with endcap, a commercially available quadrature birdcage head coil, and a four-element phased-array coil. Signal-to-noise ratio (SNR) measurements were obtained from comparison studies performed on a uniform cylindrical phantom. MRA comparisons were performed using data acquired from 15 volunteers and applying a thick-slab three-dimensional time-of-flight sequence. Analysis was performed using the signal difference-to-noise ratio, a quantitative measure of the relative vascular signal. The reduced-volume endcap and phased-array coils, which were designed specifically for imaging the intracranial volume of the head, improved the image SNR and vascular detail considerably over that obtained using the commercially available head coil. The endcap coil configuration provided the best vascular signal overall, while the phased-array coil provided the best results for arteries close to the coil elements.

Brain↗

BSH distributions in the canine head and a human patient using 11B MRI.

A 3D projection reconstruction (3DPR) method was used to obtain in vivo 11B images in a large canine brain tumor model and in a human infused with borocaptate sodium (BSH). Studies were performed in dogs with and without gliosarcomas implanted and grown to a size of 2-3 cm. The 3DPR method demonstrates a signal-to-noise ratio (SNR) that allows qualitative kinetic studies of the boron compound in normal and tumor tissue of the head. The measurements indicate initial uptake of the BSH compound in tumor to be less than that in muscle with no uptake in normal brain tissue. Moreover, uptake of BSH in tissue was found to lag the boron concentration in blood with delays that depend on tissue type. In addition, the first human boron images were obtained on a patient who underwent surgical resection and volumetric debulking of a large (7 cm) glioblastoma multiforme. BSH was readily taken up in residual tumor tissue, while diffusion into the resection volume was slower.

Animals↗